DIN Ready Solid State Relay HIGHLIGHTS !" !" !" !" !" !" !" !" !" INPUT: AC CONTROL OUTPUT: BACK-TO-BACK SCR OPTO ISOLATION 2500 VAC (4000 V optional) ZERO VOLTAGE TURN-ON or RANDOM TURN-ON BUILT IN SAFETY COVER REVERSE VOLTAGE PROTECTION FOR DC/AC RELAYS BUILT IN SNUBBER FOR HIGH DV/DT DIN MOUNT OR BACK PLATE MOUNTING LED INDICATOR SHOWING RELAY 'ON' STATUS (J: Zero voltage turn-on; K: Random turn-on) ELECTRICAL SPECIFICATIONS Parameter Type Symbol AC CONTROL Control voltage range Control current range Pick-up voltage Drop-out voltage Input resistance OUTPUT Mains control voltage Repetitive peak off state voltage RMS on-state current Zero turn-on voltage On-state voltage drop Off-state leakage current @ rated voltage Peak one cycle surge current (non-Rrep) Holding current Critical rate of rise of off-state voltage Thermal resistance (junction to case) Frequency range Storage temperature Operating temperature Turn-on time Turn-off time Fusing current VRMS VDRM IT VTM IDRM ITSM IH dv/dt Rthjc f Ts TO T-on T-off I2t Unit PSB DIN 30A 661028 PSB DIN 30A 661628 PSB DIN 30A 662528 PSB DIN 30A 664028 90-280 4-25 90 10 16-25 90-280 4-25 90 10 90-280 4-25 90 10 90-280 4-25 90 10 16-25 16-25 16-25 Vac mA Vac Vac K 48-660 1200 10 35 1.6 5 100 75 200 1.8 47-63 -30 to +100 -30 to +80 40 80 72 48-660 1200 16 35 1.6 5 250 120 200 1.3 47-63 -30 to +100 -30 to +80 40 80 128 48-660 1200 25 35 1.8 5 1000 250 700 0.43 47-63 -30 to +100 -30 to +80 40 80 3700 48-660 1200 40 35 1.8 5 1000 250 700 0.43 47-63 -30 to +100 -30 to +80 40 80 5000 Vac Vpk A Vac Vac mA A mA V/#s K/W Hz °C °C ms ms A2s ALL ELECTRICAL PARAMETERS MEASURED @ TA= 25 DEG C released, E 197669 POWERSEM reserves the right to change limits, test conditions and dimensions - [email protected] - www.POWERSEM.net POWERSEM 2007 All rights reserved DIN Ready Solid State Relay 84.0 COVER CASE SPACER HEAT SINK CLIP ASSEMBLY CLAMP LED LOCATION 22 115.0 1. 2. 3. 4. 5. 6. 7. Features of DIN Ready SSR ! ! ! ! ! ! ! ! ! ! AC SOLID STATE CONTRACTOR IN 30 mm HOUSING ZERO SWTICHING FOR HEATING AND MOTOR APPLICATIONS/RANDOM SWITICHING RATED OPERATIONAL CURRENT 10 A, 16 A & 25 A ( 40 A WITH FORCED COOLING RATED OPERATIONAL VOLTAGE 120/230 VAC, 400/480/660 TRANSIENT OVER VOLTAGE PROTECTION (OPTICAL) LED INDICATOR SHOWING RELAY ‘’ON’’ STATUS IP 20 PROTECTION DIN – RAIL AND BACK PLATE MPONTABLE CONNECTING TERMINALS LAYOUT AS CONTRACTOR OR SSR STANDARD OPTO-ISOLATION " 400 V BUILT IN SNUBBER Zero cross circuit 1 Output 2 Output 3 Input (+) 4 Input ( - ) SCHEMATIC OF J & K SERIES DC / AC RELAYS DIN SSR’s POWERSEM reserves the right to change limits, test conditions and dimensions - [email protected] - www.POWERSEM.net POWERSEM 2007 All rights reserved DIN Ready Solid State Relay DERATING CURVE FOR 10 A DIN SSR CURRENT IN AMPS 12 10 8 6 4 2 0 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE IN ° C DERATING CURVE FOR 16 A DIN SSR CURRENT IN AMPS 30 25 20 16 10 5 0 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE IN ° C POWERSEM reserves the right to change limits, test conditions and dimensions - [email protected] - www.POWERSEM.net POWERSEM 2007 All rights reserved DIN Ready Solid State Relay DERATING CURVE FOR 25 A DIN SSR CURRENT IN AMPS 30 25 20 15 10 5 0 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE IN ° C DERATING CURVE FOR 40 A DIN SSR 45 40 CURRENT IN AMPS 35 30 25 20 15 10 5 0 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE IN ° C POWERSEM reserves the right to change limits, test conditions and dimensions - [email protected] - www.POWERSEM.net POWERSEM 2007 All rights reserved