POWER-SYSTEMS CERS

DC-DC Converter UNIT
CER Series (1.5 W REGULATED DC-DC CONVERTER)
FEATURES
z
1000VDC ISOLATION
HIGH EFFICIENCY
SIX-SIDED SHIELD TO REDUCE
EMI
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 1.5W REGULATED OUTPUT
POWER
DUAL IN LINE PACKAGE
z
z
z
100% BURNED IN
LOW NOISE
MTBF > 850,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ C
O
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
+/-10% max
Input Filter
Pi Network
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-0.5% max
2
+/-0.5% max
Short Circuit Protection
Current Limit
z
GENERAL SPECIFICATIONS
Efficiency
58% min
Protection
Short Circuit Restart
z
Automatic
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Isolation Resistance
-25 C to +71 C
O
Storage Temperature
O
-55 C to +125 C
O
Isolation Voltage3
O
Switching Frequency
Isolation
1000 VDC min
9
10 ohms min
50 KHz min
80pF max
Capacitance
Cooling
Free-Air Convection
MTBF
Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
LINE,
Case Size
FULL
LOAD
,
AND
25
O
C
UNLESS
850,000 Hours
12.0g-14.4g
Six-Sided Shield Case
31.8mm*20.3mm*10.2mm
OTHERWISE NOTED.
1
High Line to Low Line.
2
Load Regulation is for output load current change from 10% to 100%.
3
For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CER Series (1.5 W REGULATED DC-DC CONVERTER)
z SELECTION GUIDE
1.5W OUTPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
EFF
ISOLATION
FULL
NO
(%)
(VDC)
LOAD
LOAD
CERS-0505M
4.5-5.5
5
300
500
40
60
1000
CERS-0512M
4.5-5.5
12
125
490
40
61
1000
CERS-0515M
4.5-5.5
15
100
490
40
61
1000
CERD-0512M
4.5-5.5
+/-12
+/-63
490
40
61
1000
CERD-0515M
4.5-5.5
+/-15
+/-50
490
40
61
1000
CERS-1205M
10.8-13.2
5
300
205
15
61
1000
CERS-1212M
10.8-13.2
12
125
195
15
64
1000
CERS-1215M
10.8-13.2
15
100
195
15
64
1000
CERD-1212M
10.8-13.2
+/-12
+/-63
195
15
64
1000
CERD-1215M
10.8-13.2
+/-15
+/-50
190
15
66
1000
CERS-2405M
21.6-26.4
5
300
100
10
63
1000
CERS-2412M
21.6-26.4
12
125
95
10
66
1000
CERS-2415M
21.6-26.4
15
100
95
10
66
1000
CERD-2412M
21.6-26.4
+/-12
+/-63
95
10
66
1000
CERD-2415M
21.6-26.4
+/-15
+/-50
93
10
67
1000
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CER Series (1.5 W REGULATED DC-DC CONVERTER)
z SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
+Vin
REGULATOR
DUAL OUTPUT
+Vout
OSCILLATOR
DRIVER
-Vin
REGULATOR
+Vin
OSCILLATOR
DRIVER
-Vout
+Vout
Com.
-Vout
-Vin
REGULATOR
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
www.Power-Systems.de
Page: 3 / 5
PIN
SINGLE
DUAL
1 & 24
+Vin
+Vin
2 & 23
NC
-Vout
3 & 22
NC
Common
10 & 15
-Vout
Common
11 & 14
+Vout
+Vout
12 & 13
-Vin
-Vin
Version: 4-Oct-02
DC-DC Converter UNIT
CER Series (1.5 W REGULATED DC-DC CONVERTER)
z TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
DUAL OUTPUT
OUTPUT
INPUT
OUTPUT
+Vout
+Vin
+Vin
+Vout
LOAD1
LOAD
DC-DC
CONVERTER
-Vin
Common
DC-DC
CONVERTER
-Vin
-Vout
LOAD2
-Vout
z TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified.
OUTPUT LOAD vs EFFICIENCY
OUTPUT LOAD vs OUTPUT VOLTAGE
OUTPUT VOLTAGE
CHANGE(%)
EFFICIENCY(%)
80%
60%
SAFE
OPERATING
AREA
40%
20%
0%
0%
20%
40%
60%
80%
10%
5%
0%
-5%
-10%
100%
0%
OUTPUT LOAD(%)
40%
60%
80% 100%
OUTPUT LOAD(%)
TEMPERATURE DERATING
INPUT VOLTAGE vs EFFICIENCY
100%
EFFICIENCY(%)
2.0
OUTPUT POWER(W)
20%
1.5
1.0
0.5
80%
60%
40%
20%
0%
0.0
-25
0
25
50
70
-10
100
Nom
5
10
INPUT VOLTAGE(%)
TA(degree C)
www.Power-Systems.de
-5
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CER Series (1.5 W REGULATED DC-DC CONVERTER)
CER SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the CER series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 100KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 220uF.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02