POWER-SYSTEMS PS-M06D05S6

DC-AC INVERTER UNIT
PS-M06D05S6-NJ4L(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Please contact us for confirmation regarding compatibility with your display.
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 500 Vrms
Lamp Current 2 x 6.5 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 5 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM-Dimming Function
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
105 x 23 x 10 mm
13 ± 0.5
CN1
PS-MXXDXX-NJX
29/01/2004
MADE IN
GERMANY
CN2
5 ± 0.5
105 ± 0.5
82 ± 0.3
(2)
15 ± 0.3
22,5 ± 0.5
-10°C ~ +60°C
-20°C ~ +85°C
95 %RH max
CAUTION
HIGH VOLTAGE
10.0MAX
3
2 - Ø2.5 ± 0.2
(for M2 screws)
Pin 1
2
1
Unit : mm
Weight :20 (g) typ.
(2)
Pin 1
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
Note
t=1.6m m
JST or equal
3
Connector CN2
1
SM04(4.0)B-BHS-1-TB
JST or equal
Input side CN1:
Output side CN2:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
Symbols
Vin
GND
Ext. PWM
N.C.
Ratings
5 Vdc
0 ~ 5 Vdc (L activ)
-
CN 1-5
Vrm t
0 / 5 Vdc (H activ)
Pin No.
CN 2-1
CN 2-2
CN 2-3
Symbols
Vhigh
Vhigh
N.C.
Ratings
500 Vrm s (6.5 m Arm s )
500 Vrm s (6.5 m Arm s )
-
CN 2-4
Vlow
0 Vdc
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.5, 12th February 2010
DC-AC INVERTER UNIT
PS-M06D05S6-NJ4L(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
5±0.05 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
4.75
5±0.25 0 ~ +60
Specification
Min.
Typ.
Max.
6.0
5.5
50
1.450
6.5
6.5
1.6
60
1.500
7.0
7.5
2.5
70
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
Please contact us for 24V input voltage.
Note 2:
Note 3:
Note 4:
TEST CIRCUIT :
F
A
Vin
5V
Iin
SW 1
1000:1
PROBE
F
Vopen V
~
CN1-1
SW3
V
Operation of unit
a
Operation
b
Non operation
CN2-1
CN1-2
SW4
CN1-3
T1
CN2-2
RL2
Ext. PWM*
0~5V
A
NC
Vrmt
2.5 Vdc ~ Vin
RL1
CL2
SW5
a
V
b
CL1
A
~
Iout ~
Iout1
2
CN1-4
CN2-4
SW1
CN1-5
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.5, 12th February 2010