DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-DA0253-11(S) (9 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This DC to AC Inverter was developed for many other low LCD
Backlight power supply as low profile applications, either for LCD
Monitor or Industrial PC.
APPLICABLE LCD:
10 to 15 inches dual lamp type
Lamp Voltage 600 Vrms
Lamp Current 2 x 6.0 mArms
Lamp Start Up Voltage 1.400 Vrms (Vin : 5 Vdc)
FEATURES :
Current Feedback Circuit
High Efficiency
Low noise with voltage resonant circuit
Regulated output current
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +50°C
-20°C ~ +85°C
95 %RH max
153 x 21.5 x 10 mm
Pin1
Unit : mm
Weight :40 (g) typ.
Pin1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No.
CN 1-1+2
CN 1-3+4
Symbols
Vin
GND
CN 1-5
Vrm t
CN 1-6
CN 1-7
Vbr
GND
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0790
SM04(4.0)B-BHS-1-TB
Output side CN2
Pin No.
Symbols
Vhigh
CN 2-1
Vhigh
CN 2-2
N.C.
CN 2-3
Vlow
CN 2-4
Ratings
4.75 ~ 5.25 Vdc
0 ~ 0.4 = OFF
/ 2.5 ~ Vin = ON
0 ~ 5.0 Vdc
-
Note
t=1m m
Molex or equal
JST or equal
Ratings
600 Vrm s (6.0 m Arm s )
600 Vrm s (6.0 m Arm s )
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.2, 02nd September 2010
DC-AC INVERTER UNIT
PS-DA0253-11(S) (9 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shutdown
Iout
Iout
Iin
F
Vopen
Ts d
Note 1 :
Vin (V)
Vbr (V)
5±0.25
5±0.12
5±0.25
5±0.25
5±0.25
5±0.25
0.0
5.0
0.0
0.0
0.0
0.0
Specification
Tu (°C)
Min.
Typ.
Max.
0
0
0
0
0
0
5.5
1.5
39.0
1.300
-
6.0
2.2
1.72
46.5
1.400
1.0
6.5
2.9
2.25
54.0
1.700
-
~ +50
~ +50
~ +50
~ +50
~ +50
~ +50
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
s ec
Dut y 100%
wit hout load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
DIMMING CHARACTERISTICS (Reference)
7,0
Iout (mArms)
6,0
5,0
4,0
3,0
2,0
1,0
0,0
0,0
0,4
0,7
1,1
1,4
1,8
Vbr (VDC)
TEST CIRCUIT :
F
Vin
4.75 ~ 5.25 V
Iin
A
1000:1
PROBE
F
Vopen
V
~
CN1-1
CN1-2
V
SW 1
Operation of unit
a
Operation
b
Non operation
CN1-3
CN2-1
CN1-4
Vrmt
0 / 5 Vdc
CN2-2
a
V
b
SW2
T1
RL2
SW1
RL1
CN1-5
CL2
A
Iout ~
2
CL1
A
~
Iout1
SW3
CN1-6
Vbr
0 ~ 5.0 Vdc
CN2-4
V
CN1-7
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)