RECTRON BAT60B

BAT60B
Small-Signal Schottky Diodes
VOLTAGE RANGE 10 Volts
FEATURES
*
*
*
*
High current rectifier Schottky diode with low VF drop
Low voltage, low inductance
For power supply
For detection and step-up-conversion
SOD-323
.071(1.80)
.063(1.60)
MECHANICAL DATA
Case: Molded plastic
Epoxy: UL 94V-O rate flame retardant
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.004 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 OC ambient temperature unless otherwise specified.
.006(.15)
.014(.35)
.010(.25)
.055(1.40)
.047(1.20)
.106(2.70)
.098(2.50)
.003(.08)
*
*
*
*
*
MAX.039(1.00)
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
REF .019(0.46)
.004(.10)
.000(.00)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@T A =25 OC unless otherwise noted)
SYMBOL
BAT60B
Non-Repetitive Peak Reverse Voltage
RATINGS
VRM
10
UNITS
Volts
Maximum Forward Comtinuous Current
IFM
3
Amps
Forward Surge Current @ t=10ms
Amps
IFSM
5
Junction Capacitance (Note 1)
CT
30
pF
Maximum Power Dissipation (Note 2)
Ptot
250
mW
Junction Temperature
TJ
150
O
TSTG
-65 to + 150
O
Storage Temperature Range
C
C
ELECTRICAL CHARACTERISTICS (@T A =25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
BAT60B
UNITS
Maximum Instantaneous Forward Voltage
@IF=10mA
@IF=100mA
@IF=500mA
@IF=1000mA
VF
300
380
500
600
mVolts
Maximum Instantaneous Peverse Current
@VR=5V
@VR=8V
IR
15
25
uAmps
NOTES : 1. Measured at 1MHz and applied reverse voltage of 5 volts.
2. Part mounted on FR-4 PC board with minimunm recommended pad layout.
2008-12
REV: A
RATING AND CHARACTERISTICS CURVES ( BAT60B )
A
3200
125 OC
10-3
mA
85 OC
10-4
2400
25 OC
2000
10-6
IR
IR
10-5
10-7
1600
1200
-40 OC
10-8
800
10-9
400
10-10
0
0
2
4
6
8
V
12
0
20
40
60
80
100
120 OC
150
S
100
FORWARD CURRENT IF = f (TS)
REVERSE CURRENT IR = f (VR)
Figure 1
Figure 2
100
102
A
10-2
IFmax/IFDC
10-1
-40 OC
IF
25 OC
85 C
O
10-3
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
101
125 OC
10-4
10-5
0
0.1
0.2
0.3
0.4
0.5
0.6
V
0.8
100
10-6
10-5
10-4
10-3
10-5
FORWARD CURRENT IF = f (VF)
PERMISSIBLE PULSE LOAD IFmax/IFDC = f (tp)
Figure 3
Figure 4
RATING AND CHARACTERISTICS CURVES ( BAT60B )
102
101
RthJS
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0
100
10-1
10-6
10-5
10-4
10-3
10-5
S
PERMISSIBLE PULS LOAD RthJS = f (tp)
Figure 5
100
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
RECTRON