RECTRON W005L_10

W005L
THRU
W10L
SINGLE-PHASE GLASS PASSIVATED
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.5 Amperes
FEATURES
*
*
*
*
*
*
High reverse voltage to 1000V
Surge overload ratings to 50 amperes peak
Good for printed circuit board assembly
Mounting position: Any
Weight: 1.37 grams
Silver-plated copper leads
RC-2
.374 (9.5)
.354 (9.0)
MECHANICAL DATA
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
.290 (7.4)
.270 (6.9)
1.0
(25.4)
MIN.
1.2
(30.5)
MIN.
.032 (0.8)
.028 (0.7)
POS.
LEAD
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
.220 (5.6)
.180 (4.6)
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.220 (5.6)
.180 (4.6)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
SYMBOL
W005L
W01L
W02L
W04L
W06L
W08L
W10L
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Output Current at T A = 50 oC
Peak Forward Surge Current 8.3 ms single half sine-wave
1.5
Amps
I FSM
50
Amps
superimposed on rated load (JEDEC method)
Typical Thermal Resistance
Operating Temperature Range
Storage Temperature Range
Volts
IO
RθJA
40
RθJC
22
TJ
-55 to + 150
0
C
T STG
-55 to + 150
0
C
0
C/W
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Forward Voltage Drop per element at 1.5A DC
Maximum Reverse Current at Rated
@T A = 25 o C
DC Blocking Voltage per element
@T A = 125 o C
Note: 1. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
VF
W005L
W01L
W02L
W04L
W06L
W08L
W10L
UNITS
1.0
Volts
5.0
uAmps
IR
0.5
mAmps
2010-10
REV: A
RATING AND CHARACTERISTIC CURVES ( W005L THRU W10L )
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
50
AVERAGE FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
SURGE CURRENT
8.3ms Single Half Sine-Wave
(JEDED Method)
40
30
20
10
1.6
1.4
1.2
1.0
.8
.6
.4
60 Hz RESISTIVE OR
INDUCTIVE LOAD
.2
0
0
1
2
4
6 8 10
20
40 60 100
20
50
NUMBER OF CYCLES AT 60Hz
80
110
140
170
AMBIENT TEMPERATURE, (
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
200
)
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
20
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
CHARACTERISTICS
10
TJ = 25
Pulse Width = 300us
1% Duty Cycle
1.0
.1
.01
10
1.0
TJ = 25
0.1
.01
0
.2
.4
.6
.8
1.0
1.2
1.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
0
20
40
60
80
100 120
PERCENT OF RATED PEAK
REVERSE VOLTAGE, (%)
RECTRON
140
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.