RFHIC RFC092

Cellular Mini Amplifier
Product Features
Application
• GaAs MMIC
• Very Low Distortion
• Guaranteed Broadband Power Gain
• Heat Sink 99.9% Copper, Ag or Gold Plate
• Excellent Thermal Conductivity
• Single Supply Voltage @ 24V
• Low DC Power Consumption
• No External Circuit needed
• Drive Amplifier
RFC092
Description
The RFC092 is specifically designed for up to 1GHz in frequency as amplifiers in BTS.
This hybrid dynamic range amplifier module operates with a single voltage supply of 24V(DC).
Specifications
Absolute Maximum Ratings
PARAMETER
MIN
MAX
UNITS
VDD / VRFOUT
0
28
VDC
RFIN
-
+22
dBm
Storage Temperature
-40
+100
℃
Operating Temperature
-20
+100
℃
Electrical Specifications (TA = +25℃, VDD = 24V~28V)
PARAMETER
RFC092
Bandwidth (MHz)
MIN
TYP
MAX
800
-
1000
23
-
-
±0.5
1.5 : 1
2.0 : 1
Gain @ 870MHz (dB)
Gain Flatness @ 870MHz (dB)
-
Input / Output VSWR
Output Power (dBm)
29
30
IMD3 (dBc)
56
60
22
24
CDMA (dBm) 29dBc @ 885kHz
44dBc @ 1.98MHz
1FA
Noise Figure (dB) @ 870MHz
Supply Current (mA)
380
4
6
400
430
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 5.6
Cellular Mini Amplifier
RFC092
S-Parameter
IMD3
CDMA 3FA TEST
CDMA 8FA TEST
CDMA 20FA TEST
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 5.6
Cellular Mini Amplifier
RFC092
< 1FA Data : At Output Power 22.5dBm >
<3FA Data : At Output Power 21.5dBm >
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 5.6
Cellular Mini Amplifier
RFC092
ESD PROTECTION
Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity.
Proper ESD control techniques should be used when handling these devices. Some of the precautions recommended are;
- Person at a workbench should be earthed via a wrist strap and a resistor.
- All mains-powered equipment should be connected to the mains via an earth-leakage switch.
- Equipment cases should be grounded.
- Relative humidity should be maintained between 40% and 50%.
- An ionizer is recommended.
- Keep static materials, such as plastic envelopes and plastic trays etc. away from the workbench.
NOTES FOR CORRECT USE
1.
2.
3.
4.
5.
6.
7.
On the power input port (Pin#5), 47uF/35V capacitor GND is
recommended.
The heat sink of CATV Hybrids is to be mounted in direct contact with the
metal case of the equipment. Heat conducting grease should be applied to
the module/equipment interface and the unit tightly secured.
Put the power off before adjusting in/output matching of the system.
The unit must have a common ground with the equipment and the
analyzer.
Pay close attention to the input voltage not to over power the hybrid.
The space between bottom of socket and the tip of the lead is
recommended to have space of 2mm+ to protect the pin
Do not open the plastic cover to change the matching inside the hybrid.
Once opened, RFHIC will not be responsible for the hybrid.
Package Dimensions (Type: DP-27)
Pin No.
Function
1
2,3,7,8
5
9
RF Input
Ground
Vcc
RF Output
RFHIC Corporation (RFHIC) reserves the right to make changes to any products herein or to discontinue any product at any time without notice. RFHIC do not
assume any liability for the suitability of its products for any particular purpose, and disclaims any and all liability, including without limitation consequential or
incidental damages. The product specifications herein expressed have been carefully checked and are assumed to be reliable. However, RFHIC disclaims liability for
inaccuracies and strongly recommends buyers to verify that the information they are using is current before placing purchase orders. RFHIC products are not
intended for use in life support equipment or application where malfunction of the product can be expected to result in personal injury or death. Buyer uses or sells
such products for any such unintended or unauthorized application, buyer shall indemnify, protect and hold RFHIC and its directors, officers, stockholders,
employees, representatives and distributors harmless against any and all claims arising out of such use. RFHIC’s liability under or arising out of damages, claims of
whatsoever kind and nature which RFHIC products could cause shall be limited in amount to the net purchase price of the products sold to buyer by RFHIC.
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 5.6