RFHIC AE366

E-pHEMT MMIC
AE366
(Preliminary)
Product Features
Application
• 50 ~ 1000MHz
• GaAs E-pHEMT MMIC
• Higher linearity, Higher Gain
• Low Noise Figure
• High Max input power
• SOT-89 SMD Type package
• Higher productivity
• Lower manufacturing cost
• Pb Free / RoHS Standard
• Receiver IF Amplifier
• Cellular, GSM
• Base station
• RF Sub-system
Package : SOT-89
Description
AE366 is a drive or pre-drive amplifier designed in a low cost SOT-89 package.
This MMIC is based on Gallium Arsenide Enhancement Mode pHEMT which shows low current and high IP3.
It is designed as driver devices for infrastructure equipment in the 50~1000MHz Wireless technologies such as IF, Cellular, GSM
System. The data in this spec sheet is valid only for 50 ohm application.
Specifications
PARAMETER
UNIT
MIN
TYP
Frequency Range
MHz
50 ~ 1000
Gain
dB
23
Input Return Loss
dB
-20
Output Return Loss
dB
-20
Output IP3
dBm
36
39
1dB Compression Point
dBm
19
22
Noise Figure
dB
1.6
DC Current
mA
95
Supply Voltage
V
5
MAX
Remark
2.1
NOTE
1. Test conditions unless otherwise noted. Freq=50~1000MHz, Vdd=+5V, Ta=25℃, 50Ω system
2. OIP3 measured with 2 tones at an output power of +10dBm/tone separated by 1MHz
Absolute Minimum and Maximum Ratings
PARAMETER
UNIT
MIN
TYP
MAX
Device Voltage
V
+5
+7
Operating Temperature
℃
-40
+85
Storage Temperature
℃
-40
+150
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 0.3
AE366
(Preliminary)
E-pHEMT MMIC
◎ Application Circuit: 50MHz ~ 1000MHz, 50ohm System
◎ Typical RF Performance: VDD=5V, IDS=95mA, TA=25℃, 50ohm System
S-parameter
Noise Figure vs Frequency
27
23
20
3.0
10
2.5
Gain(dB)
0
13
S11
8
-10
S22
3
0.0
0.2
0.4
0.6
0.8
-20
-30
1.2
1.0
Return Loss(dB)
S21
18
2.0
1.5
1.0
0.5
0.0
50
250
450
Freq(GHz)
650
850
Freq(MHz)
◎ Output data
5V, 95mA
6V, 155mA
Frequency
OIP3 (dBm)
P1dB (dBm)
Frequency
OIP3 (dBm)
P1dB (dBm)
50 MHz
37.3
22
50 MHz
39
24.2
100 MHz
38.4
22
100 MHz
39.2
24.3
250 MHz
37.9
22
250 MHz
40
24
500 MHz
37
21.7
500 MHz
39.7
23.6
850 MHz
35.6
21.1
850 MHz
38.8
23
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 0.3
1050
E-pHEMT MMIC
AE366
(Preliminary)
ESD Protection
For a safe use in all situations, it is recommended to have proper ESD control techniques while the device is being
handled. Here are some recommended precautions;
- Person at a workbench should be earthed via a wrist strap and a resistor.
- All mains-powered equipment should be connected to the mains via an earth-leakage switch.
- Equipment cases should be grounded.
- Relative humidity should be maintained between 40% and 50%.
- An ionizer is recommended.
- Keep static materials, such as plastic envelopes and plastic trays etc. away from the workbench
Dimensions
PCB Pad Layout
Pin No
Function
1
Input
2
Ground
3
Output/Bias
4
Ground
Recommended Mounting Configuration
Mounting Configuration Notes
1.Ground / thermal via holes are critical for the proper performance of this device.
2. Add as much copper as possible to inner and outer layers near the part to ensure optimal thermal performance.
3. Mounting screws can be added near the part to fasten the board to a heatsink. Ensure that the ground / thermal via hole region contacts
the heatsink.
4. Do not put solder mask on the backside of the PCB in the region where the board contacts the heatsink.
5. RF trace width depends upon the PCB material and construction.
6. Use 1 oz. Copper minimum.
7. All dimensions are in millimeters.
RFHIC Corporation (RFHIC) reserves the right to make changes to any products herein or to discontinue any product at any time without notice. RFHIC do not
assume any liability for the suitability of its products for any particular purpose, and disclaims any and all liability, including without limitation consequential or
incidental damages. The product specifications herein expressed have been carefully checked and are assumed to be reliable. However, RFHIC disclaims liability for
inaccuracies and strongly recommends buyers to verify that the information they are using is current before placing purchase orders. RFHIC products are not
intended for use in life support equipment or application where malfunction of the product can be expected to result in personal injury or death. Buyer uses or sells
such products for any such unintended or unauthorized application, buyer shall indemnify, protect and hold RFHIC and its directors, officers, stockholders,
employees, representatives and distributors harmless against any and all claims arising out of such use. RFHIC’s liability under or arising out of damages, claims of
whatsoever kind and nature which RFHIC products could cause shall be limited in amount to the net purchase price of the products sold to buyer by RFHIC.
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Version 0.3