RFSOLUTIONS 008C4

‘008’ SERIES RADIO RECEIVER DECODERS
•
•
•
•
•
•
•
•
•
•
•
FM Remote Receiver Decoder
High Security
Protocol
‘Easy Learn’ Tx Encoder Feature
Momentary or Latching Relay Outputs
Led Indication of Data Reception
Enclosure Rated IP65
Rx Decoder Can Learn up to 50 Tx Encoders
315 / 433 / 868 / 915 MHz Available
12 / 24V Power Supply
Relay Rated 12Apk at 230Vac
Requires No Radio Licence
Description
The 008 range of general purpose radio receiver decoders. When used with a matching Keeloq Transmitter
encoder, a complete Remote control system is generated.
Each Rx decoder incorporates an ‘easy learn’ feature enabling it to learn the Transmitter encoder signature code
as it is transmitted. Each 008 decoder is able to learn up to 50 individual Transmitter encoders (memorised even
if the power is removed).
Supplied in a tough ABS enclosure rated IP65, The 008 decoder requires connections to the power and output
relays only (via screw terminals)
The relay outputs are each rated 1A @ 50Vdc and may be set to either momentary or latching by two links on the
circuit board.
Part Numbering
008-315FR1
Relay
Outputs
4
Freq
(MHz)
315
Optimum
Range (m)
150
FM wideband
008-433FR4
4
433.92
200
FM wideband
Part Number
Compatible RFSL
Encoders
102C-315F series
Description
102C-433F series
102C-433Q series
008-433QR1
4
433.92
200
QM wideband
FM-103C-433 series
FM-107 Series
102C-075F series
008C4-075FR1
4
434.75
400
FM Narrowband
FM-103C-433,
FM-107 Series
008C4-915FR1
4
914.50
100
FM Narrowband
102C-915F series
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%
DS008-1 April ‘04
©2004 REG No 277 4001, England.
Page 1
‘008’ SERIES RADIO RECEIVER DECODERS
Relay Operation Table
Each of the switches on the encoder maps directly to the relay outputs. (sw1 ot rly1, sw2 to rly2 etc)
Relay 1 is rated 12A (peak) 5A continuous at 110 / 230Vac.
Relay 2-4 are rated 2A(peak) 1A continuous at 30Vdc/120Vac,
Link 1 (Lk1)
Link2 (Lk2)
Relay 1
Relay 2
Relay 3
Relay 4
Open
Open
Momentary
Momentary
Momentary
Momentary
Open
Connected
Momentary
Momentary
Latch
Latch
Connected
Open
Momentary
Latch
Latch
Latch
Connected
Connected
Latch
Latch
Latch
Latch
Note : In momentary mode the relay will operate for as long as the transmitter switch is held on.
Learning a new Transmitter Encoder
1.
2.
3.
4.
5.
Press the programming switch on the Rx decoder once (SW1)
The learn LED will illuminate
Press one of the switches on the Tx encoder once, learn LED on the Rx decoder will extinguish
Press one of the switches on the Tx encoder again, learn LED will flash
When the learn LED has stopped flashing this Tx encoder will now operate the system
Erasing Transmitter Encoders from Memory
1. To completely erase all Tx encoders, press SW1 on the Rx decoder for 10 seconds.
2. The learn LED will turn off after the 10 seconds to indicate the Tx encoder(s) have been erased
Technical Specifications
Case Dimensions: Length : 110mm (not including antenna), Width : 85mm, Height : 35mm
PCB Board Dimensions:
Length: 90.5mm, Width: 74.5mm,
Height: 22mm
o
o
Storage Temperature; -10 to +70 Celsius.
Operating Temperature; 0 to +55 Celsius.
ELECTRICAL CHARACTERISTICS
MIN
TYPICAL
MAX
DIMENSION
Supply Voltage for +12 v
9
12.0
16
V
Supply Voltage for +24 v
20
24.0
28
V
Supply Current :
Quiescent
19
mA
all relays* operating
260
Time delay from Tx on Switch to Rx Relay operation
100
mS
Time delay from Tx sw relax to Rx Relay release
300
MS
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
R F Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex, BN8 6JL, England.
Email: [email protected]
http://www.rfsolutions.co.uk
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
R F Solutions Ltd is a member of the Low Power Radio Association.
Information contained in this document is believed to be accurate, however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of
such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS008-1 April ‘04
©2004 REG No 277 4001, England.
Page 2