RHOMBUS-IND F-129

PARAMETER
(1)
Inductance
(1)
Leakage Inductance
(1)
Interwinding Capacitance
Primary DC Resistance
UNITS
85.0 Min.
µH
0.25 Max.
µH
High Frequency
Data Line Filter
12 Max.
pF
3 Coils 6 Data Lines
0.30 Max.
Ω
500 Min.
VRMS
20
MHz
10k Min.
MΩ
250
mW
Isolation (HI-POT)
SRF (Ref.)
Insulation Resistance
Power Rating
Schematic Diagram
Crosstalk 60 dB @ 5 MHz Nominal
50 dB @ 10 MHz Nominal
Longitudinal Conversion Loss
0 - 300KHz
56 dB Min.
300 KHz - 500KHz 52 db Min.
500 KHz - 1MHz
46 dB Min.
1MHz - 5 MHz
36 db Min.
Operating Temperature Range -40OC TO +85OC
Storage Temperature Range -55OC TO +125OC
Turns ratio 1:1 + 0%
Current Rating: 100mA
1
Tested at 100KHz and 500 mV RMS
Operating temperature Range
-45oC to +85oC
Physical Dimensions in inches (mm)
RHOMBUS P/N: F-129
CUST P/N:
DATE: 1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET:
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971
High Frequency
Data Line Filter:
P/N F-129G
Impedance
Impedance
(Ω)
3500
3000
2500
2000
1500
1000
500
1 MHz
Frequency
500 MHz
Crosstalk
Crosstalk ( dB )
- 40
- 50
- 60
- 70
- 80
1 MHz
Frequency
10 MHz
RHOMBUS P/N: F-129
CUST P/N:
DATE: 1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET:
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971
Crosstalk
D.U.T = F-129G
D.U.T. = F-129
Sine Wave 2VRMS
up to 10MHz
RS = 50 Ω
RL = 135 Ω
20 Log V/E
Longitudinal Conversion Loss
D.U.T = F-129G
D.U.T. = F-129
Resistors Matched to within 0.03%
R1 + R2 = 67.5 Ω
R3 + R4 = 67.5 Ω
20 Log EL/ETr
RHOMBUS P/N: F-129
CUST P/N:
DATE: 1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET:
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971