RHOMBUS-IND F-3503

Very Low Profile Tax Filters
Attenuates 12 or 16 kHz signals to
telco equipment by more than 25 dB.
Schematic
Diagram
Uses standard-value capacitor for either
12 or 16 kHz resonance
1
Designed to provide 25 dB minimum
attenuation at 12 or 16 kHz.
5
Electrical Specifications at 25O C
Part
Number
Inductance (1)
+5%
(mH)
D.C. Resistance
Max.
(Ω)
D.C. Current
Max.
(mA)
Hi-Pot
Min.
(VAC)
F-3551
2.58
14.0
70
1250
12 kHz, Parallel L with C=68 nF
F-3552
1.44
10.0
90
1250
16 kHz, Parallel L with C=68 nF
F-3553
7.96
28.0
70
1250
12 kHz, Series L with C=22 nF
F-3554
4.52
20.0
90
1250
16 kHz, Series L with C=22 nF
Attenuates
12 or 16 kHz
1. Tested at 10KHz and 100 mVRMS
Physical Dimensions
inches (mm)
}
Optional
use as
Dual
.079
(2.00)
TYP.
6
7
8
9
10
.020
(0.50)
TYP.
Use of F-3551 inductor in a parallel LC
configuration followed by a F-3553 in a
series configuration to provide more
than 40 dB attenuation of tax pulse signals
5
4
2
1
.660
(16.76)
MAX.
.768
(19.50)
.027
(0.69)
Use of F-3552 inductor in a parallel LC
configuration followed by a F-3554 in a
series configuration to provide more
than 40 dB attenuation of tax pulse signals
.172
(4.37)
MAX.
Terminal #1 Indicator
Specifications subject to change without notice.
Rhombus
Industries Inc.
.660
(16.76)
MAX.
For other values & Custom Designs, contact factory.
18
.053
(1.35)
TAXFILTR - 10/98
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971
Tax Pulse Filter Inductor
Materials used in the
construction of this
component meet or
exceed UL Class B and
can be operated up to 130oC
Single Inductance
Vary capacitor value for 12 KHz or 16 KHz
Rhombus Part Number: F-3503
Electrical Specifications at 25O C
Parameter
Min.
Typ.
Max.
Units
Schematic
Inductance (Pins 1-3)
6.19
6.52
6.84
mH
1
D.C. Resistance
10.5
12.05
13.6
Ω
70
mADC
Current
"12 KHz" Capacitor
25.0
27.0
28.0
nF
"16 KHz" Capacitor
14.0
15.0
15.7
nF
Single LC attenuation
25
dB
Dual LC attenuation
40
dB
3
1. Tested at 10KHz and 100 mVRMS
Table #1
Physical Dimensions in inches (mm)
“Tax Pulse” Frequencies
for various countries:
Country
Frequency
Austria
12 kHz
Belgium
16 kHz
Switzerland
12 kHz
Germany
16 kHz
Denmark
12 kHz
Spain
12 kHz
France
12 kHz
Great Britain
50 Hz*
Greece
16 kHz
Italy
12 kHz
Ireland
12 kHz
Israel
16 kHz
Norway
16 kHz
Netherlands
50 Hz*
Portugal
12 kHz
Sweden
12 kHz
Finland
16 kHz
Turkey
12 kHz
Yugoslavia
16 kHz
Australia
12 kHz
Czechoslovakia 16 kHz
.450
(11.43)
MAX.
.200
(5.08)
.025
(0.64)
TYP.
.400
(10.16)
.571
(14.50)
MAX.
2
1
3
.551
(14.00)
MAX.
6
5
4
*Common-mode
(longitudinal) signal
Specifications subject to change without notice.
Rhombus
Industries Inc.
For other values & Custom Designs, contact factory.
19
TAXFILTR - 10/98
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971