RHOMBUS-IND L-268

Vertical & Horizontal Mount Inductors
Electrical Specifications at 25OC
Vert.
Part
Number
Horiz.
Part
Number
L (1)
Typ.
(µH)
IDC (2)
20%
Amps
IDC (3)
50%
Amps
I (4)
max.
Amps
Energy
min. (5)
(µJ)
DCR
nom.
(mΩ)
L-268
L-291
L-269
L-270
100
250
1.56
1.21
3.72
2.88
2.81
1.97
136
136
170
351
1) Typical Inductance with no DC. Tolerance of +10%.
2) Current which will produce a 20% reduction in L
3) Current which will produce a 50% reduction in L
4) Maximum DC current. This value is for a 40OC temperature rise due to copper loss, with AC flux
density kept to 10 Gauss or less. (This typically represents a current ripple of less than 1%)
5) Energy storage capability of component in micro Joules. Value is for 20% reduction in permeability.
Vertical
Physical Dimensions
inches (mm)
Footprint - Vertical
Horizontal
Specifications are subject to change without notice
Rhombus
Industries Inc.
Transformers & Magnetic Products
Footprint - Horizontal
L-268 - 5/96
www.rhombus-ind.com
15801 Chemical Lane
Huntington Beach, California 92649-1595
Phone: (714) 898-0960 • FAX: (714) 896-0971