RHOMBUS-IND L

HDSL Common Mode Choke
Typical Impedance Curve
Parameter
Min.
Inductance
7.5
Max.
Units
12.5
mH
Leakage Inductance
20
µH
DCR
1.5
Ω
Isolation
Typ.
600
Im pe da nce ( k Ω )
Electrical Specifications at 25OC
VRMS
250
200
150
100
50
0
100
200
Test Conditions:
Inductance & Leakage Inductance tested at 20mVRMS and 20 kHz
500
1000
2000
Frequency ( kHz )
Physical Dimensions
inches (mm)
Pin Position Grid 0.100"
Bobbin Terminations
Schematic
Diagram
PRI
SEC
1
6
2
7
3
8
4
9
5
10
RHOMBUS P/N: L-286
CUST P/N:
DATE: 7/1/96
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
Rhombus
Industries Inc.
Transformers & Magnetic Products