RHOMBUS-IND T

T1/CEPT/ISDN PRI Interface Transformer
Turns Ratio ( + 5% )
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
1CT:1CT (T1) & 1CT:2CT (T2)
PARAMETER
MIN.
OCL (Primary)
1.2
MAX.
UNITS
mH
Leakage Inductance
0.6
µH
Capacitance (CW/W)
30
pF
Primary DC Resistance
0.7
Ohms
0.7 & 1.0
Ohms
Secondary DC Resistance
ET Product
10
Operating Temp Range
-40
Primary Pins 14-16 & 6-8
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
VµS
+85
C
0
Isolation 1500 VRMS Min.
PHYSICAL DIMENSIONS inches (mm)
Schematic Diagram
Primary
T1
Secondary
Rhombus
Industries Inc.
Transformers & Magnetic Products
Secondary
T2
Primary
Rhombus P/N:
Cust. P/N:
5/21/98
Date:
T-14169
Name:
Sheet:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971