RHOMBUS-IND T

T1/CEPT/ISDN PRI Interface Transformer
Electrical Specifications @ 250C
Turns Ratio ( + 3% )
1CT : 2.42CT (T1) & 1CT : 2.42CT (T2)
PARAMETER
MIN.
OCL (Primary)
1.20
MAX.
UNITS
mH
Leakage Inductance
0.6
µH
Capacitance (CW/W)
25
pF
Primary DC Resistance
0.7
Ohms
Secondary DC Resistance
1.2
Ohms
Operating Temp Range
-40
+85
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
0
Contains both transmit and
receive transformers
Parts shipped in anti-static
tubes. 33 pieces per tube
C
Isolation 1500 VRMS Min.
Primary Pins 1-3 & 6-8
Tape & Reel
Available
PHYSICAL DIMENSIONS
inches (mm)
Schematic Diagram
Secondary
T1
Primary
Rhombus
Industries Inc.
Transformers & Magnetic Products
Secondary
T2
Primary
Rhombus P/N: T-14178
Cust. P/N:
10/20/99
Date:
ww.rhombus-ind.com
Name:
Sheet:
1 of 1
15801 Chemical Lane,
Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971