RHOMBUS-IND T

T1/CEPT/ISDN PRI Interface Transformer
Electrical Specifications @ 250C
*
Turns Ratio ( + 3% )
1:1:1.27 & 1CT:2CT
PARAMETER
MIN.
OCL (Primary)
1.5 & 2.0
UNITS
mH
Leakage Inductance
0.6 & 0.8
µH
Capacitance (CW/W)
50 & 45
pF
Primary DC Resistance
0.9 & 1.0
Ohms
Secondary DC Resistance
1.1 & 2.0
Ohms
Operating Temp Range
Primary Pins 14-16 & 6-8
*
MAX.
-40
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
0
+85
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
C
Isolation 2000 VRMS Min.
Pins 14-16 to 2-3 = 1:1
Pins 14-16 to 1-3 = 1.27
PHYSICAL DIMENSIONS
inches (mm)
Schematic Diagram
Rhombus P/N:
T-14170
Cust. P/N: 640-1099-02
1/23/98
Date:
Rhombus
Industries Inc.
Transformers & Magnetic Products
FSCM No.
16714
Name: PAIRGAIN
1 of 1
Sheet:
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971