Platinum Temperature Sensor CPT 100 SMD 1206
Technical Data
Construction
SMD 1206
Specification
DIN EN 60751
Resistance at 0°C
100 Ω
Temperature coefficient
(0°C up to 100°C)
3.85 · 10-3 K-1
Tolerance class to DIN EN 60751
A, B
Operating temperature range
-50 °C up to 150 °C
Measurement current (DC)
at 25°C
Advanced thin-film-technology (ceramic carrier with
a structured platinum layer, covered
with a
passivating layer)
1 mA
Conformity
Maximal permissible peak current
(DC) at 25 °C
3 mA
2002/95/EC Restriction of the use of Hazardous
Substances Directive (RoHS)
Insulation resistance
> 10 MΩ
Dimensions [mm]
Self-heating at 0 °C
< 0.4 K / mW
0.55 + 0.25
- 0.1
Technology
Thermal response time
Flowing water (v = 0.2 m/s)
T0.5 = 0.2 s
T0.9 = 0.5 s
Flowing air (v = 1 m/s)
Protective layer
Solder joint
0.5 ± 0.25
Ceramic carrier
T0.5 = 4 s
Resistance value at
at 0 °C
(Tolerance class A)
100.00 Ω ± 0.060 Ω
at 100 °C
(Tolerance class A)
138.51 Ω ± 0.13 Ω
at 0 °C
(Tolerance class B)
100.00 Ω ± 0.12 Ω
at 100 °C
(Tolerance class B)
138.51 Ω ± 0.30 Ω
Maximal Resistance Change
at UCT 250 h
1.5 + 0.25
- 0.05
T0.9 = 10 s
0.5 ± 0.25
3 + 0.35
- 0.1
< 0.1 %
Functional performance
according to DIN EN 60751
± 1,50
Class
Class
Class
Class
± 1,00
A [Ω]
B [Ω]
A [°C]
B [°C]
± 1,00
± 0,50
± 0,50
± 0,00
Temperature tolerance [°C]
Resistance tolerance [Ω]
± 1,50
± 0,00
-50
0
50
100
150
Whereby:
RT … Resistance [Ω] at temperature T
Ro … Resistance [Ω] at 0 °C
T … Temperature [°C]
∆T … Permissible temperature deviation at T [°C]
A = 3.9083 · 10-3 °C-1
B = - 5.775 · 10-7 °C-2
C = - 4.183 · 10-12 °C-4
Fields of application
Picture 1: Resistance and temperature tolerances of CPT 100 SMD 1206
• Industrial electronics
• Automotive electronics
• Energy and environmental engineering
Temperature range of -50 °C up to 0 °C:
RT = Ro · (1 + A · T + B · T2 + C · (T – 100 °C) · T3)
Ordering information
Temperature [°C]
Please use the following code:
Temperature range of 0°C up to 150°C:
RT = Ro · (1 + A · T + B · T2 )
Tolerance classes to DIN EN 60751:
Class A: ∆T = ± (0.15 + 0.002 · | T |)
Class B: ∆T = ± (0.3 + 0.005 · | T |)
Product
code
Type
Construction
Class of Temperature
accuracy range [°C]
51206902
CPT 100
SMD 1206
A
-50/150
51206901
CPT 100
SMD 1206
B
-50/150
ISO/TS 16949:2002
Reg.-Nr. 44 111 068108
Other classes of accuracy are available on request.
DIN EN ISO 14001:2005
Reg.-Nr. 44 104 068108
Made in Germany
Revision
07/01
© UST Umweltsensortechnik GmbH 2007
Subject to alterations for this information and technological changes
UST Umweltsensortechnik GmbH
Dieselstr. 2, 98716 Geschwenda, Germany
Phone +49 36205 713-0
Fax +49 36205 713-10
[email protected]