100W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105 long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
OUTPUT
INPUT
RS-100-3.3
RS-100-5
RS-100-12
RS-100-15
RS-100-24
RS-100-48
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
20A
16A
8.5A
7A
4.5A
2.3A
CURRENT RANGE
0 ~ 20A
0 ~ 16A
0 ~ 8.5A
0 ~ 7A
0 ~ 4.5A
0 ~ 2.3A
RATED POWER
66W
80W
102W
105W
108W
110.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
120mVp-p
120mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
2.0%
11.4 ~ 13.2V
1.0%
14.25 ~ 16.5V
1.0%
22.8 ~ 26.4V
1.0%
45.6 ~ 52.8V
1.0%
3.2V ~ 3.5V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
Note.4
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
Note.5
2.0%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
500ms, 20ms/230VAC
HOLD TIME (Typ.)
100ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
74%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.5A/115VAC
1.5A/230VAC
COLD START 40A/230VAC
LEAKAGE CURRENT
1200ms, 30ms/115VAC at full load
18ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
77%
81%
82%
84%
84%
27.6 ~ 32.4V
55.2 ~ 64.8V
<2mA / 240VAC
110 ~ 150% rated output power
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 6)
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
260.8Khrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
0.6Kg; 24pcs/15.4Kg/0.7CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RS-100-SPEC 2005-09-13
RS-100
100W Single Output Switching Power Supply
Mechanical Specification
Case No. 901C
series
Unit:mm
3.5
7
152.5
1
3
84.5
8.2
4
5
2-M
6
97
65
9.5
2
3
7
3.5
4.5
78
24
159
150
22
38
28.5
M3
18
3.5
3-
3.5
18.5
9
9
6.5
117
Terminal Pin. No Assignment
Pin No.
1
2
3
Pin No.
4,5
6,7
Assignment
AC/L
AC/N
FG
Assignment
DC OUTPUT -V
DC OUTPUT +V
Output Derating
Static Characteristics
Ta=25
100
100
Others
90
80
80
70
3.3V,5V
LOAD (%)
LOAD (%)
60
40
20
-25
-25
0
0
10
20
30
40
AMBIENT TEMPERATURE (
50
60
60
50
40
70 (VERTICAL)
88
95
100
)
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RS-100-SPEC 2005-09-13
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
ELECTRONIC COMPONENTS
■
Änderungen vorbehalten / subject to change without notice
■
■
■