RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ■ ELECTRONIC COMPONENTS ■ ■ ■ Änderungen vorbehalten / subject to change without notice RS-100 100W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL DC VOLTAGE OUTPUT INPUT RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48 3.3V 5V 12V 15V 24V 48V RATED CURRENT 20A 16A 8.5A 7A 4.5A 2.3A CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.3A RATED POWER 66W 80W 102W 105W 108W 110.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 2.0% 11.4 ~ 13.2V 1.0% 14.25 ~ 16.5V 1.0% 22.8 ~ 26.4V 1.0% 45.6 ~ 52.8V 1.0% 3.2V ~ 3.5V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION Note.4 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 2.0% 1.0% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 500ms, 20ms/230VAC HOLD TIME (Typ.) 100ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC 1.5A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT 1200ms, 30ms/115VAC at full load 18ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 77% 81% 82% 84% 84% 27.6 ~ 32.4V 55.2 ~ 64.8V <2mA / 240VAC 110 ~ 150% rated output power OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE EMC (Note 6) I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 260.8Khrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.6Kg; 24pcs/15.4Kg/0.7CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. File Name:RS-100-SPEC 2005-09-13 RS-100 100W Single Output Switching Power Supply Mechanical Specification Case No. 901C series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2-M 6 97 65 9.5 2 3 7 3.5 4.5 78 24 159 150 22 38 28.5 M3 18 3.5 3- 3.5 18.5 9 9 6.5 117 Terminal Pin. No Assignment Pin No. 1 2 3 Pin No. 4,5 6,7 Assignment AC/L AC/N FG Assignment DC OUTPUT -V DC OUTPUT +V Output Derating Static Characteristics Ta=25 100 100 Others 90 80 80 70 3.3V,5V LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 60 60 50 40 70 (VERTICAL) 88 95 100 ) 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RS-100-SPEC 2005-09-13 RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ELECTRONIC COMPONENTS ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■