SI-8001FDL DC-to-DC Step-Down Converter Features and Benefits Description ▪ 3.5 A output current supplied in a small, surface mount power package ▪ High efficiency: 83% at VIN = 15 V, IO = 2.0 A,VO = 5 V ▪ Requires only six external components ▪ Oscillation circuit built-in (frequency 300 kHz typical) ▪ Constant-current mode overcurrent protection circuit and overtemperature protection circuit built-in ▪ Output-on state at low level ▪ Low current consumption during output-off state The SI-8001FDL DC voltage regulator is a DC-to-DC buck convertor that attains an oscillation frequency of 300 kHz, and has an integrated miniaturized choke coil, allowing it to serve as a small, high efficiency power supply in a compact TO263 package. The internal switching regulator function provides high efficiency switching regulation without any need for adjustment. The device requires only six external support components. Optional on/off control can be performed using a transistor. The SI-8001FDL includes overcurrent and overtemperature protection circuits. Applications include: ▪ DVD recorder ▪ FPD TV ▪ Telecommunications equipment ▪ Office automation equipment, such as printers ▪ On-board local power supply ▪ Output voltage regulator for second stage of SMPS (switched mode power supply) Package: TO263-5 Not to scale Functional Block Diagram VIN 1 IN SW C1 PReg On/Off Latch and Driver C2 R1 Osc Comparator Overtemperature Protection Error Amplifier GND 3 ADJ 4 R2 Reference Voltage 27469.064-I VOUT L1 Di SPB-G56S (Sanken) Overcurrent Protection Reset 5 VC 2 SI-8001FDL DC-to-DC Step-Down Converter Selection Guide Part Number Output Voltage Adjustable Range (V) Efficiency, Typ. (%) Input Voltage, Max. (V) Output Current, Max. (A) Packing SI-8001FDL-TL 0.8 to 24 83 40 3.5 800 pieces per reel Absolute Maximum Ratings Characteristic Symbol DC Input Voltage VIN VC Pin Control Voltage VC Remarks Rating Units 43 V VIN V 3 W –40 to 150 °C –40 to 150 °C Power Dissipation PD Mounted on 40 mm × 40 mm exposed copper area on 40 mm × 40 mm glass-epoxy PCB; limited by internal overtemperature protection. Junction Temperature TJ Internal overtemperature protection circuit may enable when TJ ≥ 130°C. During product operation, recommended TJ ≤ 125°C. Storage Temperature Tstg Thermal Resistance (junction-to-case) RθJC Mounted on 40 mm × 40 mm exposed copper area on 40 mm × 40 mm glass-epoxy PCB. 3 °C/W Thermal Resistance (junction-to-ambient air) RθJA Mounted on 40 mm × 40 mm exposed copper area on 40 mm × 40 mm glass-epoxy PCB. 33.3 °C/W Recommended Operating Conditions* Characteristic Symbol DC Input Voltage Range VIN DC Output Voltage Range VO DC Output Current Range IO Operating Junction Temperature Range TJOP Operating Temperature Range TOP Remarks VIN (min) is the greater of 4.5 V or VO+3 V. VIN ≥ VO + 3 V; to be used within the allowable package power dissipation characteristics (refer to Power Dissipation chart). To be used within the allowable package power dissipation characteristics (refer to Power Dissipation chart). Min. Max. Units See remarks 40 V 0.8 24 V 0 3.5 A –30 100 °C –30 85 °C *Required for normal device functioning according to Electrical Characteristics table. All performance characteristics given are typical values for circuit or system baseline design only and are at the nominal operating voltage and an ambient temperature, TA, of 25°C, unless otherwise stated. Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 2 SI-8001FDL DC-to-DC Step-Down Converter ELECTRICAL CHARACTERISTICS1, valid at TA = 25°C, VO = 5 V (adjusted), R1 = 4.2 kΩ, R1 = 0.8 kΩ Characteristic Test Conditions1 Symbol Reference Voltage VADJ Reference Voltage Temperature Coefficient ∆VADJ /∆T VIN = 15 V, IO = 0.2 A Min. Typ. Max. 0.784 0.800 0.816 V – ±0.1 – mV/°C VIN = 15 V, IO = 0.2 A, TC = 0 to 100 °C Units Efficiency2 η VIN = 15 V, IO = 2 A – 83 – % Operating Frequency fO VIN = 15 V, IO = 2 A 270 300 330 kHz Line Regulation VLine VIN = 10 to 30 V, IO = 2 A – – 80 mV Load Regulation VLoad VIN = 15 V, IO = 0.2 to 3.5 A – – 50 mV Overcurrent Protection Threshold Current IS VC Terminal Control Voltage (On) VC(IH) VC Terminal Control Voltage (Off) VC(IL) VC Terminal Control Current (On) IC(IH) VIN = 15 V 3.6 – – A – – 0.8 V 2 – – V VC = 2 V – 6 100 μA Quiescent Current 1 Iq VIN = 15 V, IO = 0 A – 6 – mA Quiescent Current 2 Iq(off) VIN = 15 V, VC = 0 V – 30 200 μA 1Using circuit shown in Typical Application Circuit diagram. 2Efficiency is calculated as: η(%) = ([V × I ] × [V × I ]) × 100. O O IN IN 1 2 3 4 5 Terminal List Table Name Number IN 1 Function Supply voltage SW 2 Regulated supply output GND 3 Ground terminal ADJ 4 Terminal for resistor bridge feedback VC 5 If the VC terminal is left open, output will be in the on state. Because the input level is equivalent to LS-TTL, direct drive by LS-TTL is possible. VC Pin Control Input Current versus Input Voltage IO = 0 A, TA = 25°C, R1 = 4.2 kΩ, R2 = 0.8 kΩ 40 30 IC (μA) Pin-out Diagram 20 10 0 0 10 20 VC (V) Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 30 40 3 SI-8001FDL DC-to-DC Step-Down Converter Performance Characteristics At TA = 25°C, VO = 5 V Adjusted, R1 = 4.2 kΩ, R2 = 0.8 kΩ 6.00 90 15 V Efficiency versus Output Current VO= 3.3 V η (%) 80 0.5 A VIN 4.00 Low Voltage Behavior: Output Voltage versus Supply Voltage 20 V 75 30 V 70 40 V VO (V) 8V 0 0.5 1.0 1.5 2.0 IO (A) 2.5 3.0 0 3.5 1 2 3 4 5 VIN (V) 5.08 15 V 85 VIN 6 7 8 VIN 5.06 5.04 20 V 75 Load Regulation: 5.02 Output Voltage 5.00 versus Output Current 4.98 40 V 4.96 10 V VO (V) 80 η (%) 0 5.10 8V 30 V 70 40 V 30 V 15 V 4.94 65 60 3.5 A 1.00 90 Efficiency versus Output Current VO= 5.0 V 1A 2A 3.00 2.00 65 60 0A IO 5.00 85 8V 4.92 4.90 0 0.5 1.0 1.5 2.0 IO (A) 2.5 3.0 0 3.5 100 1 2 IO (A) 10 20 VIN (V) 3 10 95 20 V 15V VIN 8 Quiescent Current versus Supply Voltage IO = 0 A VC = 0 V 85 30 V 80 Iq (mA) Efficiency versus Output Current VO= 12.0 V η (%) 90 40 V 0 70 0 0.5 1.0 1.5 2.0 IO (A) 2.5 3.0 3.5 50 0 30 40 6 5 40 8V Overcurrent Protection: Output Voltage versus Output Current 30 20 4 VO (V) IQ (μA) 4 2 75 Behavior at Turn-Off: Quiescent Current versus Input Voltage IO = 0 A VC = 2 V 6 VIN 15 V 3 30 V 2 10 40 V 1 0 0 0 10 20 VIN (V) 30 40 0 1 Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 2 IO (A) 3 4 5 4 SI-8001FDL DC-to-DC Step-Down Converter Thermal Performance Characteristics The application must be designed to ensure that the TJ(max) of the device is not exceeded during operation. To do so, it is necessary to determine values for maximum power dissipation, PD(max), and ambient temperature, TA(max). Power Dissipation versus Ambient Temperature TJ(max) = 125°C; Mounted on glass-epoxy PCB (40 mm × 40 mm), with varying exposed copper areas 3.5 Cu Area: 1600 mm2 RθJA = 33.3°C/W The relationships of TJ, PD, TA, and case temperature, TC, are as shown in the following formulas: PD = TJ – TC RθJC and PD = TJ – TA RθJA 3.0 Cu Area: 800 mm2 RθJA = 37°C/W . 2.5 PD can be calculated from input values: ⎞ ⎟⎟ ⎠ Cu Area: 400 mm2 RθJA = 44°C/W 2.0 PD (W) ⎛ 100 ⎞ ⎛ V − 1⎟⎟ − VF ⋅ I O ⎜⎜1 − O PD = VO ⋅ I O ⎜⎜ ⎝ Hx ⎠ ⎝ VIN Cu Area: 100 mm2 RθJA = 53°C/W 1.5 where: VO is output voltage in V, ηx is IC efficiency in percent (varies with VIN and IO; refer to efficiency performance curves for value), and VF is forward voltage for the input diode, Di. In these tests, the Sanken SPB-G56S was used, at 0.4 V. For application design, obtain thermal data from the datasheet for the diode. PD is substantially affected by the heat conductance properties of the application, in particular any exposed copper area on the PCB where the device is mounted. The relationships of PD, TA, and copper area is represented in the Power Dissipation chart. RθJA for a given copper area can be determined form the Device Thermal Resistance chart. This can be substituted into the formula above to determine the TJ (max) allowable in the application. Generally, more than 10% to 20% derating is required. Because the heat dissipation capacity of the copper area depends substantively on how it is used in the actual application, thermal characteristics of the application must be confirmed by testing. TC is determined by connecting a thermocouple to the device as shown here: Thermocouple mount at tab center 0.5 0 –25 0 25 50 75 100 125 TA (°C) Device Thermal Resistance versus Exposed Copper Area on PCB Glass-epoxy PCB, 40 mm × 40 mm 55 50 45 40 35 30 0 200 400 600 800 1000 1200 1400 1600 1800 Copper Area (mm2) 6 OTP On 5 Overtemperature Protection: Output Voltage versus Junction Temperature 4 VO (V) IO is output current in A, 1.0 RθJA(°C/W) VIN is input supply voltage in V, VIN = 15 V, IO = 10 mA 3 2 1 And analyzing the results using the following formula: TJ = PD × RθJC + TC , OTP Off 0 0 for this device, RθJC is 3 °C/W. Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 20 40 60 80 100 TJ (°C) 120 140 160 180 5 SI-8001FDL DC-to-DC Step-Down Converter Component Selection Diode Di A Schottky-barrier diode must be used for Di. If other diode types are used, such as fast recovery diodes, the IC may be destroyed because of the reverse voltage applied by the recovery voltage or ON voltage. Choke Coil L1 If the winding resistance of the choke coil is too high, the efficiency may be reduced below rating. Because the overcurrent protection start current is approximately 4.2 A, attention must be paid to the heating of the choke coil by magnetic saturation due to overload or short-circuited load. Capacitors C1 and C2 Because for SMPS, large ripple currents flow across C1 and C2, capacitors with high frequency and low impedance must be used. If the impedance of C2 is too high, the switching waveform may not be normal at low temperatures. Do not use either OS or tantalum types of capacitors for C2, because the extremely low ESR causes an abnormal oscillation. The device is stabilized, and for proper operation, C1 must be located close to the device (see layout diagram, below). Resistor Bridge R1 and R2 comprise the resistor bridge for the output voltage, VO, and are calculated as follows: (V − V ) (V − 0.8) (Ω) , and R2 = VADJ = 0.8 = 0.8 (k Ω ) R1 = O ADJ = O −3 −3 1 × 10 IADJ 1 × 10 IADJ IADJ should always be set to 1 mA. Note that R2 should always be present to ensure stable operation, even if VO, is set to 0.8 V (that is, even if there is no R1). VO should be at least VIN + 8%. Typical Application Diagram VIN 1 IN SW L1 2 SI-8001FDL VC GND 3 5 C1 ADJ VO Component R1 4 IADJ Di R2 Rating C1 C2 Di L1 470 μF 680 μF SPB-G56S (Sanken) 47 μH C2 GND GND Recommended PCB Layout Recommended Solder Pad Layout 11±0.2 9±0.2 6.8±0.1 Vc 9±0.1 Di 3.7±0.05 R2 R1 4±0.1 1±0.05 All external components should be mounted as close as possible to the SI-8001FDL. The ground of all components should be connected at one point near GND pin (pin 3). 1.7±0.1 (mm) Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 6 SI-8001FDL DC-to-DC Step-Down Converter 9.90 ±0.20 0.80 ±0.10 2.00 ±0.10 3º (R0.30) (0.50) 6º 0º 4×P1.70 ±0.25 2.40 ±0.20 2.54 ±0.30 0.88 ±0.10 0.10 ±0.15 3º (0.75) 4.90 ±0.20 XXXXXXXX + (R0.45) 3XR0.30 15.30 ±0.30 XXXXXXXX XXXXXXXX Branding (4.40) + 3º 9.20 ±0.20 XXXXXXXX (4.60) Ø1.5 ±0.20 (0.40) 1.30 –0.05 (0.75) +0.10 3XR0.30 15º (8.00) (6.80) 4.50 ±0.20 2.20 ±0.20 PACKAGE OUTLINE DRAWING 2XR0.30 3º 1 2 3 4 10.00 ±0.02 5 Dimensions do not include mold protrusion Heastsink side flash: 0.8 mm maximum Dimensions in millimeters Branding codes (exact appearance at manufacturer discretion): 1st line: SK 2nd line, lot: YMW X Where: Y is the last digit of the year of manufacture M is the month (1 to 9, O, N, D) W is the week of the month (1 to 5) X is the device subtype suffix number 3rd line, type: 8001FDL RoHS directive compliant Device pins lead (Pb) free Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 7 SI-8001FDL DC-to-DC Step-Down Converter 2.0 ±0.10 11.5 ±0.05 B A Ø1.5 MIN A 16.0 0.4 ±0.05 15.7 +0.1 –0.0 24.3 ±0.03 4.0 ±0.10 Ø1.5 1.75 ±0.10 TAPE AND REEL SPECIFICATION 3.9 B 4.9 10.6 View A-A View B-B Material: conductive polysterene Material: Conductive polysterene Camber < 1mm mmlength over 100 length of tape Camber < 1 mm over 100 of tape Pocketmeasured inner widths measured 0.3 mm above floor of pocket Pocket inner widths 0.3 mm above floor of cavity Pocket position relative to sprocket hole measured to true position of pocket 10 sprocket hole pitch cumulative ±0.2 mm Pocket center and pocket hole center ±0.3 mm Surface resistivity < 107 Ω / cm2 Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 8 SI-8001FDL DC-to-DC Step-Down Converter PACKING SPECIFICATION Inner Carton 800 pieces per reel 2 reels per carton 341 65 344 Outer Carton 3 inner cartons per outer carton 450 230 Dimensions in mm 350 Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 9 SI-8001FDL DC-to-DC Step-Down Converter WARNING — These devices are designed to be operated at lethal voltages and energy levels. Circuit designs that embody these components must conform with applicable safety requirements. Precautions must be taken to prevent accidental contact with power-line potentials. Do not connect grounded test equipment. The use of an isolation transformer is recommended during circuit development and breadboarding. solder bath must be grounded in other to prevent leak voltages generated by them from being applied to the products. • The products should always be stored and transported in our shipping containers or conductive containers, or be wrapped in aluminum foil. Soldering • When manually soldering the products, please be sure to minimize the working time, within the following limits: Soldering Iron Temperature (°C) Time (s) 380±10 3 (once only) • Reflow soldering can be performed a maximum of twice, using the following recommended profile: 250°C Maximum 250 230 Temperature (°C) Cautions for Use • Operation of the product in parallel to increase current is not permitted. • Although the product has an internal overtemperature protection circuit, that is intended only to protect the product from temporary excess heating due to overloads. Long-term reliability cannot be guaranteed when the product is operated under continuous overload conditions. Because reliability can be affected adversely by improper storage environments and handling methods, please observe the following cautions. Cautions for Storage • Ensure that storage conditions comply with the standard temperature (5°C to 35°C) and the standard relative humidity (around 40 to 75%); avoid storage locations that experience extreme changes in temperature or humidity. • Avoid locations where dust or harmful gases are present and avoid direct sunlight. • Reinspect for rust on leads and solderability of products that have been stored for a long time. Cautions for Testing and Handling When tests are carried out during inspection testing and other standard test periods, protect the products from power surges from the testing device, shorts between adjacent products, and shorts to the heatsink. Electrostatic Discharge • When handling the products, operator must be grounded. Grounded wrist straps worn should have at least 1 MΩ of resistance to ground to prevent shock hazard. • Workbenches where the products are handled should be grounded and be provided with conductive table and floor mats. • When using measuring equipment such as a curve tracer, the equipment should be grounded. • When soldering the products, the head of soldering irons or the 180 30 ±10s 150 90 ±30s Time Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 10 SI-8001FDL DC-to-DC Step-Down Converter Application and operation examples described in this document are quoted for the sole purpose of reference only, for the use of the products herein, and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights, or any other rights of Sanken or any third party which may result from its use. When using the products herein, the applicability and suitability of such products for an intended purpose or object shall be reviewed at the user’s responsibility. Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures including safety design of the equipment or systems against any possible injury, death, fires or damages to the society due to device failure or malfunction. Sanken products listed in this document are designed and intended for the use as components in general purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment measuring equipment, etc.). Before placing an order, the user’s written consent to the specifications is requested. When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), please contact your nearest Sanken sales representative to discuss and obtain written confirmation of your specifications. The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited. Anti radioactive ray design is not considered for the products listed herein. If there is any discrepancy between English and Japanese versions of this datasheet, the Japanese version should take precedence over the English one. Please accept in advance that the content of this datasheet is subject to change without notice for the purpose of such as improvement of the product. Copyright © 2007 Sanken Electric Co., Ltd. This datasheet is based on Sanken datasheet SSJ-03151 Sanken Electric Co., Ltd. 3-6-3 Kitano, Niiza-shi, Saitama-ken 352-8666, Japan Phone:+81-48-472-1111 http://www.sanken-ele.co.jp 11 DC-to-DC Step-Down Converter SI-8001FDL June, 2007 <Worldwide Contacts> Asia Pacific China Sanken Electric Hong Kong Co., Ltd. Suite 1026 Ocean Centre, Canton Road, Tsimshatsui, Kowloon, Hong Kong Tel: 852-2735-5262 Fax: 852-2735-5494 Sanken Electric (Shanghai) Co., Ltd. Room3202, Maxdo Centre, Xingyi Road 8, Changning district, Shanghai, China Tel: 86-21-5208-1177 Fax: 86-21-5208-1757 Taiwan Sanken Electric Co., Ltd. Room 1801, 18th Floor, 88 Jung Shiau East Road, Sec. 2, Taipei 100, Taiwan R.O.C. Tel: 886-2-2356-8161 Fax: 886-2-2356-8261 India Saket Devices Pvt. Ltd. Office No.13, First Floor, Bandal - Dhankude Plaza, Near PMT Depot, Paud Road, Kothrud, Pune - 411 038, India Tel: 91-20-5621-2340 91-20-2528-5449 Fax: 91-20-2528-5459 Japan Sanken Electric Co., Ltd. Overseas Sales Headquaters Metropolitan Plaza Bldg. 1-11-1 Nishi-Ikebukuro, Toshima-ku, Tokyo 171-0021, Japan Tel: 81-3-3986-6164 Fax: 81-3-3986-8637 Korea Sanken Electric Korea Co., Ltd. Mirae Asset Life Bldg. 6F, 168 Kongduk-dong, Mapo-ku, Seoul, 121-705, Korea Tel: 82-2-714-3700 Fax: 82-2-3272-2145 Singapore Sanken Electric Singapore Pte. Ltd. 150 Beach Road, #14-03 The Gateway West, Singapore 189720 Tel: 65-6291-4755 Fax: 65-6297-1744 Sanken Electric Co., Ltd. I02-006EA-070628 DC-to-DC Step-Down Converter SI-8001FDL June, 2007 Europe United Kingdom Sanken Power Systems (UK) Limited Pencoed Technology Park, Pencoed, Bridgend CF35 5HY. UK Tel: 44-1656-869-100 Fax: 44-1656-869-162 North America United States Allegro MicroSystems, Inc. 115 Northeast Cutoff, Worcester, Massachusetts 01606, U.S.A. Tel: 1-508-853-5000 Fax: 1-508-853-3353 Allegro MicroSystems, Inc. (Southern California) 14 Hughes Street, Suite B105, Irvine, CA 92618 Tel: 1-949-460-2003 Fax: 1-949-460-7837 Sanken Electric Co., Ltd. I02-006EA-070628