SI-8001FDE Datasheet

SI-8001FDE
DC-to-DC Step-Down Converter
Features and Benefits
Description
▪ 3.5 A output current supplied in a small, surface mount
power package
▪ High efficiency: 83% at VIN = 15 V, IO = 2.0 A,VO = 5 V
▪ Requires only six external components (optional soft
start requires an additional capacitor)
▪ Oscillation circuit built-in (frequency 300 kHz typical)
▪ Constant-current mode overcurrent protection circuit and
overtemperature protection circuit built-in
▪ Soft start function built-in (can be implemented as an
on/off function; output-off state at low level)
▪ Low current consumption during output-off state
The SI-8001FDE DC voltage regulator is a DC-to-DC buck
convertor that attains an oscillation frequency of 300 kHz,
and has an integrated miniaturized choke coil, allowing it to
serve as a small, high efficiency power supply in a compact
TO263 package.
Package: TO263-5
Applications include:
▪ DVD recorder
▪ FPD TV
▪ Telecommunications equipment
▪ Office automation equipment, such as printers
▪ On-board local power supply
▪ Output voltage regulator for second stage of SMPS
(switched mode power supply)
The internal switching regulator function provides high
efficiency switching regulation without any need for adjustment.
The device requires only six external support components. The
optional soft start function requires an additional capacitor.
Optional on/off control can be performed using a transistor.
The SI-8001FDE includes overcurrent and overtemperature
protection circuits.
Not to scale
Functional Block Diagram
VIN
1 IN
SW
C1
PReg
C3
On/Off
Soft Start
Latch and
Driver
C2
R1
Osc
Comparator
Overtemperature
Protection
Error
Amplifier
ADJ
4
R2
Reference
Voltage
GND
3
27469.056
VOUT
L1
Di
SPB-G56S
(Sanken)
Overcurrent
Protection
Reset
5 SS
2
SANKEN ELECTRIC CO., LTD.
http://www.sanken-ele.co.jp/en/
SI-8001FDE
DC-to-DC Step-Down Converter
Selection Guide
Part Number
Output Voltage
Adjustable Range
(V)
Efficiency,
Typ.
(%)
Input Voltage,
Max.
(V)
Output Current,
Max.
(A)
Packing
SI-8001FDE-TL
0.8 to 24
83
40
3.5
800 pieces per reel
Absolute Maximum Ratings
Characteristic
Symbol
Remarks
DC Input Voltage
VIN
Power Dissipation
PD
Mounted on 40 mm × 40 mm exposed copper area on 40 mm
× 40 mm glass-epoxy PCB; limited by internal overtemperature
protection.
Junction Temperature
TJ
Internal overtemperature protection circuit may enable when TJ ≥
130°C. During product operation, recommended TJ ≤ 125°C.
Storage Temperature
Tstg
Thermal Resistance (junction-to-case)
RJC
Mounted on 40 mm × 40 mm exposed copper area on 40 mm ×
40 mm glass-epoxy PCB.
Thermal Resistance (junction-to-ambient air)
RJA
Mounted on 40 mm × 40 mm exposed copper area on 40 mm ×
40 mm glass-epoxy PCB.
Rating
Units
43
V
3
W
–40 to 150
°C
–40 to 150
°C
3
°C/W
33.3
°C/W
Recommended Operating Conditions*
Characteristic
Symbol
DC Input Voltage Range
VIN
DC Output Voltage Range
VO
DC Output Current Range
IO
Operating Junction Temperature Range
TJOP
Operating Temperature Range
TOP
Remarks
VIN (min) is the greater of 4.5 V or VO+3 V.
VIN ≥ VO + 3 V; to be used within the allowable package
power dissipation characteristics (refer to Power Dissipation
chart).
To be used within the allowable package power dissipation
characteristics (refer to Power Dissipation chart).
Min.
Max.
Units
See
remarks
40
V
0.8
24
V
0
3.5
A
–30
100
°C
–30
85
°C
*Required for normal device functioning according to Electrical Characteristics table.
All performance characteristics given are typical values for circuit or
system baseline design only and are at the nominal operating voltage and
an ambient temperature, TA, of 25°C, unless otherwise stated.
27469.056
SANKEN ELECTRIC CO., LTD.
2
SI-8001FDE
DC-to-DC Step-Down Converter
ELECTRICAL CHARACTERISTICS1, valid at TA = 25°C, VO = 5 V (adjusted), R1 = 4.2 kΩ, R1 = 0.8 kΩ
Characteristic
Test Conditions1
Symbol
Reference Voltage
VADJ
Reference Voltage Temperature Coefficient
VIN = 15 V, IO = 0.2 A
∆VADJ /∆T
Max.
Units
0.816
V
VIN = 15 V, IO = 0.2 A, TC = 0 to 100 °C
–
±0.1
–
mV/°C
VIN = 15 V, IO = 2 A
–
83
–
%
fO
VIN = 15 V, IO = 2 A
270
300
330
kHz
–
–
80
mV
Line Regulation
VLine
VIN = 10 to 30 V, IO = 2 A
Load Regulation
VLoad
VIN = 15 V, IO = 0.2 to 3.5 A
Overcurrent Protection Threshold Current
Typ.
0.800
η
Efficiency2
Operating Frequency
Min.
0.784
IS
VIN = 15 V
SS Terminal On/Off Operation Threshold Voltage
VSSL
SS Terminal On/Off Operation Outflow Current
ISSL
Quiescent Current 1
Iq
Quiescent Current 2
Iq(off)
–
–
50
mV
3.6
–
–
A
–
–
0.5
V
VSSL = 0 V
–
6
30
μA
VIN = 15 V, IO = 0 A
–
6
–
mA
VIN = 15 V, VSS = 0 V
–
200
600
μA
1Using
circuit shown in Typical Application Circuit diagram.
2Efficiency is calculated as: η(%) = ([V × I ] × [V × I ]) × 100.
O
O
IN
IN
Pin-out Diagram
Terminal List Table
Name
Number
IN
1
Supply voltage
Function
SW
2
Regulated supply output
GND
3
Ground terminal
ADJ
4
Terminal for resistor bridge feedback
The SS terminal is used to enable soft start and to control on/off operation of the IC output,
VO (see figure 2). If neither soft start nor on/off control is used, leave pin open.
SS
1
2
3
4
5
To enable soft start, connect a capacitor between SS and ground. To control on/off
operation, connect an NPN bipolar transistor, in a TTL open collector output configuration,
between the SS terminal and GND. Turn off is done by decreasing VSSL below its rated
level.
When both soft start and VO on/off are used, a protection measure such as current limiting
is required because, if the capacitance of C3 large, the discharge current of C3 flows
across the transistor for on/off operation. Because a pull-up type resistor is provided inside
the IC, no external voltage can be applied.
5
SI-8000FDE
SS
5
System
TTL
SI-8000FDE
SI-8000FDE
SS
5
SS
5
C3
System
TTL
(a)
VO on/off
control only
(b)
Soft start
only
C3
(c)
VO on/off and
soft start control
Figure 2. Alternative configurations for SS pin. If neither soft start nor VO on/off is required, the SS pin is left open.
27469.056
SANKEN ELECTRIC CO., LTD.
3
SI-8001FDE
DC-to-DC Step-Down Converter
Performance Characteristics
At TA = 25°C, VO = 5 V Adjusted, R1 = 4.2 kΩ, R2 = 0.8 kΩ
6.00
90
15 V
Efficiency versus
Output Current
VO= 3.3 V
η (%)
80
0.5 A
VIN
4.00
Low Voltage
Behavior:
Output Voltage
versus
Supply Voltage
20 V
75
30 V
70
40 V
VO (V)
8V
0
0.5
1.0
1.5
2.0
IO (A)
2.5
3.0
0
3.5
1
2
3
4
5
VIN (V)
5.08
15 V
85
VIN
6
7
8
VIN
5.06
5.04
80
20 V
75
40 V
Load Regulation:
5.02
Output Voltage
5.00
versus
Output Current
4.98
VO (V)
η (%)
0
5.10
8V
30 V
70
30 V
15 V
10 V
4.96
40 V
4.94
65
60
3.5 A
1.00
90
Efficiency versus
Output Current
VO= 5.0 V
1A
2A
3.00
2.00
65
60
0A
IO
5.00
85
8V
4.92
4.90
0
0.5
1.0
1.5
2.0
IO (A)
2.5
3.0
0
3.5
100
1
2
IO (A)
10
20
VIN (V)
3
10
95
20 V
15V
VIN
8
Quiescent Current
versus
Supply Voltage
IO = 0 A
SS pin open
85
30 V
80
Iq (mA)
Efficiency versus
Output Current
VO= 12.0 V
η (%)
90
40 V
6
4
2
75
0
70
0
0.5
1.0
1.5
2.0
IO (A)
2.5
3.0
3.5
400
0
30
40
6
5
8V
300
Overcurrent
Protection:
Output Voltage
versus
Output Current
200
4
VO (V)
IQ (μA)
Behavior at
Turn-Off:
Quiescent Current
versus
Input Voltage
IO = 0 A
VSS = 0 V
VIN
15 V
3
30 V
2
40 V
100
1
0
0
0
27469.056
0.5
1.0
1.5
2.0
VIN (V)
2.5
3.0
3.5
0
SANKEN ELECTRIC CO., LTD.
1
2
IO (A)
3
4
5
4
SI-8001FDE
DC-to-DC Step-Down Converter
Thermal Performance Characteristics
The application must be designed to ensure that the TJ(max)
of the device is not exceeded during operation. To do so, it is
necessary to determine values for maximum power dissipation,
PD(max), and ambient temperature, TA(max).
Power Dissipation versus Ambient Temperature
TJ(max) = 125°C; Mounted on glass-epoxy PCB (40 mm × 40 mm),
with varying exposed copper areas
3.5
Cu Area: 1600 mm2
RθJA = 33.3°C/W
The relationships of TJ, PD, TA, and case temperature, TC, are as
shown in the following formulas:
PD =
TJ – TC
RθJC
and
PD =
TJ – TA
RθJA
3.0
Cu Area: 800 mm2
RθJA = 37°C/W
.
2.5
PD can be calculated from input values:
⎞
⎟⎟
⎠
Cu Area: 400 mm2
RθJA = 44°C/W
2.0
PD (W)
⎛ 100 ⎞
⎛ V
− 1⎟⎟ − VF ⋅ I O ⎜⎜1 − O
PD = VO ⋅ I O ⎜⎜
⎝ Hx
⎠
⎝ VIN
Cu Area: 100 mm2
RθJA = 53°C/W
1.5
where:
VO is output voltage in V,
1.0
ηx is IC efficiency in percent (varies with VIN and IO; refer to
efficiency performance curves for value), and
VF is forward voltage for the input diode, Di. In these tests, the
Sanken SPB-G56S was used, at 0.4 V. For application design,
obtain thermal data from the datasheet for the diode.
PD is substantially affected by the heat conductance properties of
the application, in particular any exposed copper area on the PCB
where the device is mounted. The relationships of PD, TA, and
copper area is represented in the Power Dissipation chart.
RθJA for a given copper area can be determined form the Device
Thermal Resistance chart. This can be substituted into the formula
above to determine the TJ (max) allowable in the application.
Generally, more than 10% to 20% derating is required.
Because the heat dissipation capacity of the copper area depends
substantively on how it is used in the actual application, thermal
characteristics of the application must be confirmed by testing.
TC is determined by connecting a thermocouple to the device as
shown here:
Thermocouple mount
at tab center
0.5
0
–25
0
25
75
100
125
Device Thermal Resistance versus Exposed Copper Area on PCB
Glass-epoxy PCB, 40 mm × 40 mm
55
50
45
40
35
30
0
200
400
600
800
1000
1200
1400
1600
1800
Copper Area (mm2)
6
OTP On
5
Overtemperature
Protection:
Output Voltage versus
Junction Temperature
VIN = 15 V, IO = 10 mA
And analyzing the results using the following formula:
TJ = PD × RθJC + TC ,
for this device, RθJC is 3 °C/W.
27469.056
50
TA (°C)
SANKEN ELECTRIC CO., LTD.
4
VO (V)
IO is output current in A,
RθJA(°C/W)
VIN is input supply voltage in V,
3
2
1
OTP Off
0
0
20
40
60
80 100
TJ (°C)
120
140
160
180
5
SI-8001FDE
DC-to-DC Step-Down Converter
Component Selection
Diode Di A Schottky-barrier diode must be used for Di. If other
diode types are used, such as fast recovery diodes, the IC may be
destroyed because of the reverse voltage applied by the recovery
voltage or ON voltage.
Choke Coil L1 If the winding resistance of the choke coil is too
high, the efficiency may be reduced below rating. Because the
overcurrent protection start current is approximately 4.2 A, attention must be paid to the heating of the choke coil by magnetic
saturation due to overload or short-circuited load.
Capacitors C1, C2, and C3 Because for SMPS, large ripple
currents flow across C1 and C2, capacitors with high frequency
and low impedance must be used. If the impedance of C2 is too
high, the switching waveform may not be normal at low temperatures. Do not use either OS or tantalum types of capacitors for
C2 or C3, because the extremely low ESR causes an abnormal
oscillation.
The device is stabilized, and for proper operation, C1 must be
located close to the device (see layout diagram, below). C3 is
required only if the soft start function is used. If not using softstart, leave the SS terminal open. A pull-up resistor is provided
inside the IC.
Resistor Bridge R1 and R2 comprise the resistor bridge for the
output voltage, VO, and are calculated as follows:
(V − V ) (V − 0.8) (Ω) , and R2 = VADJ = 0.8 = 0.8 (k Ω )
R1 = O ADJ = O
−3
−3
1 × 10
IADJ
1 × 10
IADJ
IADJ should always be set to 1 mA. Note that R2 should always be
present to ensure stable operation, even if VO, is set to 0.8 V (that
is, even if there is no R1). VO should be at least VIN + 8%.
Typical Application Diagram
VIN
1
IN
SW
L1
2
SI-8001FDE
SS GND
3
5
C1
GND
ADJ
VO
R1
4
IADJ
Di
C3
Soft Start Only
R2
C2
Component
C1
C2
C3
Di
L1
Rating
470 μF
680 μF
0.1 μF (For soft start function)
SPB-G56S (Sanken)
47 μH
GND
Recommended PCB Layout
Recommended Solder Pad Layout
11±0.2
9±0.2
6.8±0.1
9±0.1
3.7±0.05
4±0.1
1±0.05
All external components should be mounted as close as possible
to the SI-8001FDE. The ground of all components should be
connected at one point near GND pin (pin 3).
27469.056
SANKEN ELECTRIC CO., LTD.
1.7±0.1
(mm)
6
SI-8001FDE
DC-to-DC Step-Down Converter
9.90 ±0.20
0.80 ±0.10
2.00 ±0.10
3º
(R0.30)
(0.50)
6º
0º
4×P1.70 ±0.25
2.40 ±0.20
2.54 ±0.30
0.88 ±0.10
0.10 ±0.15
3º
(0.75)
4.90 ±0.20
XXXXXXXX
+
(R0.45)
3XR0.30
15.30 ±0.30
XXXXXXXX
XXXXXXXX
Branding
(4.40)
+
3º
9.20 ±0.20
XXXXXXXX
(4.60)
Ø1.5 ±0.20
(0.40)
1.30 –0.05
(0.75)
+0.10
3XR0.30
15º
(8.00)
(6.80)
4.50 ±0.20
2.20 ±0.20
PACKAGE OUTLINE DRAWING
2XR0.30
3º
1
2
3
4
10.00 ±0.02
5
Branding codes (exact appearance at manufacturer discretion):
Dimensions do not include mold protrusion
Heastsink side flash: 0.8 mm maximum
Dimensions in millimeters
1st line:
SK
2nd line, lot:
YMW X
Where: Y is the last digit of the year of manufacture
M is the month (1 to 9, O, N, D)
W is the week of the month (1 to 5)
X is the device subtype suffix number
3rd line, type: 8001FDE
RoHS directive compliant
Device pins lead (Pb) free
27469.056
SANKEN ELECTRIC CO., LTD.
7
SI-8001FDE
DC-to-DC Step-Down Converter
27469.056
solder bath must be grounded in other to prevent leak voltages
generated by them from being applied to the products.
•
The products should always be stored and transported in our
shipping containers or conductive containers, or be wrapped in
aluminum foil.
Soldering
•
When manually soldering the products, please be sure to
minimize the working time, within the following limits:
Soldering Iron Temperature
(°C)
Time
(s)
380±10
3
(once only)
•
Reflow soldering can be performed a maximum of twice, using
the following recommended profile:
250°C Maximum
250
230
Temperature (°C)
Cautions for Use
•
Operation of the product in parallel to increase current is not
permitted.
•
Although the product has an internal overtemperature protection
circuit, that is intended only to protect the product from temporary
excess heating due to overloads. Long-term reliability cannot
be guaranteed when the product is operated under continuous
overload conditions.
Because reliability can be affected adversely by improper storage
environments and handling methods, please observe the following
cautions.
Cautions for Storage
•
Ensure that storage conditions comply with the standard
temperature (5°C to 35°C) and the standard relative humidity
(around 40 to 75%); avoid storage locations that experience
extreme changes in temperature or humidity.
•
Avoid locations where dust or harmful gases are present and
avoid direct sunlight.
•
Reinspect for rust on leads and solderability of products that have
been stored for a long time.
Cautions for Testing and Handling
When tests are carried out during inspection testing and other
standard test periods, protect the products from power surges
from the testing device, shorts between adjacent products, and
shorts to the heatsink.
Electrostatic Discharge
•
When handling the products, operator must be grounded.
Grounded wrist straps worn should have at least 1 MΩ of
resistance to ground to prevent shock hazard.
•
Workbenches where the products are handled should be
grounded and be provided with conductive table and floor mats.
•
When using measuring equipment such as a curve tracer, the
equipment should be grounded.
•
When soldering the products, the head of soldering irons or the
180
30 ±10s
150
SANKEN ELECTRIC CO., LTD.
90 ±30s
Time
8
SI-8001FDE
DC-to-DC Step-Down Converter
• The contents in this document are subject to changes, for improvement and other purposes, without notice. Make sure that this is the
latest revision of the document before use.
• Application and operation examples described in this document are quoted for the sole purpose of reference for the use of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights or
any other rights of Sanken or any third party which may result from its use.
• Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures
including safety design of the equipment or systems against any possible injury, death, fires or damages to the society due to device
failure or malfunction.
• Sanken products listed in this document are designed and intended for the use as components in general purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.).
When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and
its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), and whenever
long life expectancy is required even in general purpose electronic equipment or apparatus, please contact your nearest Sanken sales
representative to discuss, prior to the use of the products herein.
The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required
(aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited.
• In the case that you use Sanken products or design your products by using Sanken products, the reliability largely depends on the
degree of derating to be made to the rated values. Derating may be interpreted as a case that an operation range is set by derating the
load from each rated value or surge voltage or noise is considered for derating in order to assure or improve the reliability. In general,
derating factors include electric stresses such as electric voltage, electric current, electric power etc., environmental stresses such
as ambient temperature, humidity etc. and thermal stress caused due to self-heating of semiconductor products. For these stresses,
instantaneous values, maximum values and minimum values must be taken into consideration.
In addition, it should be noted that since power devices or IC's including power devices have large self-heating value, the degree of
derating of junction temperature affects the reliability significantly.
• When using the products specified herein by either (i) combining other products or materials therewith or (ii) physically, chemically
or otherwise processing or treating the products, please duly consider all possible risks that may result from all such uses in advance
and proceed therewith at your own responsibility.
• Anti radioactive ray design is not considered for the products listed herein.
• Sanken assumes no responsibility for any troubles, such as dropping products caused during transportation out of Sanken's distribution network.
• The contents in this document must not be transcribed or copied without Sanken's written consent.
27469.056
SANKEN ELECTRIC CO., LTD.
9