SCHURTER FRT250T

FRT 250T
Non resettable fuses
www.schurter.com/pg01_2
Subminiature Fuse, 11.5 x 5 mm, Träge T
IEC 60127-4 · 250 VAC · Time-Lag T
Description
Applications
-Not recommended for new designs
-Primary Protection on PCB
-Power Supply Adapter for e.g. laptops
Standards
References
-IEC 60127-4/1
-UL 248-14
-CSA C22.2 no. 248.14
General Product Information
Time-Current Curves see last page
Corresponding Fuseholder 231819 Packaging Details
Approvals
-UL File Number: E41599
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Housing
Material: Terminals
Unit Weight
Storage Conditions
Product Marking
250 VAC
0.2 - 10 A
50 A - 100 A
Time-Lag T
PCB,THT
-40 °C to 85 °C
40/085/21 acc. to IEC 60068-1
Thermoplastic, UL 94V-0
Tin-Plated Copper
0.72 g
0 °C to 60 °C, max. 70% r.h.
, Current Rating, Voltage Rating,
Characteristic, Breaking Capacity, Approvals
Dimensions
Length
11.5
11.5
Soldering Methods
Solderability
Resistance to Soldering Heat
Resistance to Vibration
Wave, Iron
235 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 1
260 °C / 5 sec acc. to IEC 60068-2-20,
Test Tb, method 1A
acc. to IEC 60068-2-6, test Fc
11.5 mm
5
+0.1
0
7.5
19
3.5
8
1
7.5
7.5
ø 0.6
Drilling Diagram
Pre-Arcing Time
Rated Current In
0.2 A - 10 A
1.25 x In min. 2.0 x In max. 10.0 x In min.
60 min
120 s
10 ms
10.0 x
In max.
100 ms
Fuses
FRT 250T
Non resettable fuses
www.schurter.com/pg01_2
Variants
Distributor-Stock-Check | SCHURTER-Stock-Check | e-Store
S = Short Terminals
L = Long Terminals
T = Taped and Reeled
.
Rated Current [A]
Rated Voltage [VAC]
0.2
250
Breaking
Capacity
Voltage Drop
1.0 In typ.
[mV]
Power Dissipation 1.25 In
typ. [mW]
Melting I²t
10.0 Intyp.
[A²s]
S
1)
235
85
0.1
l
l
l
7100.1008.xx
T
Order Number
0.25
250
1)
180
80
0.2
l
l
l
7100.1009.xx
0.315
250
1)
130
70
0.3
l
l
l
7100.1010.xx
0.4
250
1)
130
90
0.49
l
l
l
7100.1011.xx
0.5
250
1)
120
110
0.53
l
l
l
7100.1012.xx
0.63
250
1)
100
115
1.13
l
l
l
7100.1013.xx
0.8
250
2)
230
330
1.5
l
l
l
7100.1014.xx
1
250
2)
155
300
1.6
l
l
l
7100.1015.xx
1.25
250
2)
120
270
3
l
l
l
7100.1016.xx
1.6
250
2)
120
375
4.9
l
l
l
7100.1017.xx
2
250
2)
105
400
7
l
l
l
7100.1018.xx
2.5
250
3)
95
420
7.3
l
l
l
7100.1019.xx
3.15
250
3)
92
520
4.7
l
l
l
7100.1020.xx
4
250
3)
90
600
25
l
l
l
7100.1021.xx
5
250
3)
92
800
32
l
l
l
7100.1022.xx
6.3
250
4)
93
680
53
l
l
l
7100.1023.xx
8
250
4)
65
500
87
l
l
l
7100.1024.xx
l
l
10
250
4)
63
900
160
l
0.2
250
1)
235
85
0.1
l
l
l l
7100.1108.xx
0.25
250
1)
180
80
0.2
l
l
l l
7100.1109.xx
0.315
250
1)
130
70
0.3
l
l
l l
7100.1110.xx
0.4
250
1)
130
90
0.49
l
l
l l
7100.1111.xx
0.5
250
1)
120
110
0.53
l
l
l l
7100.1112.xx
0.63
250
1)
100
115
1.13
l
l
l l
7100.1113.xx
0.8
250
2)
230
330
1.5
l
l
l l
7100.1114.xx
1
250
2)
155
300
1.6
l
l
l l
7100.1115.xx
1.25
250
2)
120
270
3
l
l
l l
7100.1116.xx
1.6
250
2)
120
375
4.9
l
l
l l
7100.1117.xx
7100.1025.xx
2
250
2)
105
400
7
l
l
l l
7100.1118.xx
2.5
250
3)
95
420
7.3
l
l
l l
7100.1119.xx
3.15
250
3)
92
520
4.7
l
l
l l
7100.1120.xx
4
250
3)
90
600
25
l
l
l l
7100.1121.xx
5
250
3)
92
800
32
l
l
l l
7100.1122.xx
6.3
250
4)
93
680
53
l
l
l l
7100.1123.xx
8
250
4)
65
500
87
l
l
l l
7100.1124.xx
10
250
4)
63
900
160
l
l
l l
7100.1125.xx
1) UL : 35 A @ 250 VAC/DC / 10 kA @ 125 VAC, p.f. = 0.7 - 0.8
2) UL: 50 A @ 250 VAC/DC / 10 kA @ 125 VAC, p.f. = 0.7 - 0.8
3) UL: 50 A @ 250 VAC, p.f. ≥ 0.95
4) UL: 63 A @ 250 VAC, p.f. ≥ 0.95
Packaging Unit L
.xx = .13 / S = Short Terminals Plastic Bag (100 pcs.) .xx = .13 / L = Long Terminals Plastic Bag (100 pcs.) .xx = .95 / T = Reeled Taped 36 cm Reel (500 pcs.) .xx = .96 / T = Reeled Taped 36 cm Reel (1000 pcs.) Fuses
FRT 250T
Non resettable fuses
www.schurter.com/pg01_2
Time-Current Curves
100000
10000
1000
Time in Seconds
100
10
1
0.1
0.01
0.001
1
10
Multiple of Rated Current In
The specifications, descriptions and illustrations indicated in this document are based
on
Fuses