CHERRY 0001.2506.TR

SPT 5x20 Pigtail
Non resettable fuses
www.schurter.com/pg01_2
Miniature Fuse with Pigtail, 5.4 x 22.5 mm, Time-Lag T, H, 250 VAC, UL: 115 - 300 VDC
IEC 60127-2 · 250 VAC · 300 VDC · Time-Lag T
Description
Applications
-IEC Standard Fuse
-H = High Breaking Capacity (Ceramic Tube)
-Primary Protection on PCB
-Power Supply Adapter for e.g. laptops
-SMPS (Switching Mode Power Supply) for TV's and DVD's
Standards
-IEC 60127-2/5
-UL 248-14
-CSA C22.2 no. 248.14
References
Approvals
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check
Packaging Details
Weblinks
-UL File Number: E41599
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Admissible Ambient Air Temp.
Climatic Category
Material: Tube
Material: Endcaps
Material: Axial Leads
Unit Weight
Storage Conditions
Product Marking
250 VAC 300 VDC
0.5 - 16 A
500 A - 1500 A
Time-Lag T
-55 °C to 125 °C
55/125/21 acc. to IEC 60068-1
Ceramic
Nickel-Plated Copper Alloy
Tin-Plated Copper
1.68 g
0 °C to 60 °C, max. 70% r.h.
, Current, Voltage, Characteristic,
Breaking Capacity, Approvals
Dimensions
Soldering Methods
Solderability
Resistance to Soldering Heat
Wave, Iron
235 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 1
260 °C / 5 sec acc. to IEC 60068-2-20,
Test Tb, method 1A
22.5 mm
øA
ø 5.4 ±0.2
.xx = .TR: 75 ±0.3
.xx = .PT: 40 ±0.2
max. 22.5
.xx = .PT: 40 ±0.2
In ≤ 6.3 A: ØA = 0.65 mm
8 A ≤ In ≤ 12.5 A: ØA = 0.8 mm
In ≥ 16 A: ØA = 1.0 mm
Fuses
SPT 5x20 Pigtail
Non resettable fuses
www.schurter.com/pg01_2
Pre-Arcing Time
Rated Current In
1.5 x In min.
2.1 x In max.
2.75 x In min. 2.75 x In max.
4.0 x In min.
4.0 x In max.
0.5 A - 0.8 A
60 min
30 min
250 ms
1 A - 3.15 A
60 min
30 min
750 ms
4 A - 6.3 A
60 min
30 min
8 A - 10 A
30 min
12.5 A - 16 A
15 min
10.0 x In min. 10.0 x In max.
80 s
50 ms
5s
5 ms
150 ms
80 s
95 ms
5s
10 ms
150 ms
750 ms
80 s
150 ms
5s
10 ms
150 ms
30 min
750 ms
80 s
150 ms
5s
10 ms
150 ms
30 min
750 ms
80 s
150 ms
5s
20 ms
150 ms
Variants
Rated Current [A]
Rated Voltage [VAC]
Rated Voltage [VDC]
0.5
250
300
0.8
250
300
1
250
1.25
1.6
Breaking
Capacity
Voltage Drop
1.0 In max.
[mV]
Voltage Drop
1.0 In typ.
[mV]
Power Dissipation 1.5 In
max. [mW]
Power Dissipation 1.5 In
typ. [mW]
Melting I²t
10.0 Intyp.
[A²s]
1)
850
360
1600
500
0.5
l
0001.2501.xx
1)
500
260
1600
500
2.3
l
0001.2503.xx
300
1)
350
180
2500
500
1.1
l
0001.2504.xx
250
300
1)
300
150
2500
500
1.86
l
0001.2505.xx
250
300
1)
200
130
2500
500
4.35
l
0001.2506.xx
2
250
300
1)
190
120
2500
600
9.2
l
0001.2507.xx
2.5
250
300
1)
180
100
2500
600
11.7
l
0001.2508.xx
3.15
250
300
1)
140
100
4000
800
33.7
l
0001.2509.xx
4
250
150
2)
100
90
4000
900
62.4
l
0001.2510.xx
5
250
150
2)
100
90
4000
1200
97.5
l
0001.2511.xx
6.3
250
150
2)
100
70
4000
1200
171
l
0001.2512.xx
8
250
150
3)
100
70
4000
1300
268
l
0001.2513.xx
10
250
150
3)
100
70
4000
2100
400
l
0001.2514.xx
12.5
250
125
4)
-
70
-
3100
563
l
0001.2515.xx
16
250
125
4)
-
70
-
4000
1500
l
0001.2516.xx
1) IEC: H = 1500 A @ 250 VAC, p.f. = 0.7 - 0.8
1) UL: 10 kA @ 125 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 250 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 300 VDC
2) IEC: H = 1500 A @ 250 VAC, p.f. = 0.7 - 0.8
2) UL: 10 kA @ 125 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 250 VAC, p.f. = 0.7 - 0.8 / 1500 A @ 150 VDC
3) IEC: 1000 A @ 250 VAC
3) UL: 1000 A @ 250 VAC, 1500 A @ 150 VDC
4) IEC: 500 A @ 250 VAC
4) UL: 500 A @ 125 VAC, p.f. = 0.7 - 0.8 / 1000 A @ 125 VAC / 500 A @ 250 VAC / 1500 A @ 125 VDC
Packaging Unit Order Number
.xx = .PTBulk (1000 pcs.)
.xx = .TRTaped 33 cm Reel (1000 pcs.)
Fuses
SPT 5x20 Pigtail
Non resettable fuses
www.schurter.com/pg01_2
Time-Current-Curves
100000
≤ 0.8 A
1 – 3.15 A
4 – 10 A
_> 12.5 A
10000
1000
Time in Seconds
100
10
1
0.1
0.01
0.001
1
10
Multiple of Rated Current In
The specifications, descriptions and illustrations indicated in this document are based
on
Fuses
current information. All content is subject to modifications and amendments.