6135 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole C14 70° C Description Characteristics -Panel Mount: Snap-in version from front side -2 Functions: Appliance Inlet, Protection class I, Circuit breaker type TA35, 2-pole -Quick connect terminal 6.3 x 0.8 mm -Alternative: version for 16 A (20 A) 6136 -Substitute for type 7764 -Unwired -Switch non-illuminated or illuminated Thermal overload protection -Qualified for use in equipment according IEC/EN 60950 Other versions on request -Pre-wired version -Quick-connect terminals 4.8 x 0.8 mm -Protection class II, 70°C Approvals References -VDE License Number: 40023066 -UL License Number: E96454 General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, Distributor-StockCheck, Accessories Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 °C to 60 °C from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class 1 acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Snap-in1.5/2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance Inlet Circuit Breakers Connectors C14 acc. to IEC/EN 60320-1 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Conditional short circuit Inc: 2000 A 6135 Power entry modules without line filter www.schurter.com/pg05 Dimensions 65.4 mm 10.6 31.8 +0.20 0 +0.20 0 59 65.4 27.4 3.2 58.8 x 27.2 30 6 max. R 0.2 S ± 0.05 R3 28.4 Diagrams L L' P1 2) PE PE' TA35 1) N N' P2 1) Line 2) Load Connectors 6135 Power entry modules without line filter www.schurter.com/pg05 ORDER CODE Table 1 Selection for type TA35 Switch Switch 1 2 LINE LINE LOAD LOAD CBT without illumination illuminated Order example 2-pole Number of switched poles Number of protected poles CBD W F 120 C0 CBD C12 C14 240 V 120 V TA35- No other features C32 C34 Other versions on request Colours Switch front W B 3 4 6 Rocker black black black black black non-illuminated illuminated white black – – – – – red transparent green transparent orange transparent Other colours on request Rocker legend 0 K printed L printed l M printed OFF OFF printed white 0 l H Colour of print white 0 embossed l F ON Illustration ON Surface black black Other legends on request Position of the rocker legend e.g. F Rated current In (A) In Code In Code 1,0 2,0 4,0 5,0 6,0 J10 J20 040 050 060 8,0 10,0 12,0 15,0 080 100 120* 150* Other rated currents on request *) UL / CSA only Connectors 6135 Power entry modules without line filter www.schurter.com/pg05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A [ min ] [ sec ] 10'000 Tripping characteristics In > 3 ... 15 A Type p Rated current Ambient temp. 60 [ min ] [ sec ] 10'000 TA35 <3A (TC-1, TC-2) +23 °C 60 2`000 30 20 20 1`000 10 500 TA35 > 3–15A (TC-1, TC-2) +23 °C 2`000 30 1`000 10 Type Rated current Ambient temp. 500 5 5 200 200 100 100 1 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tr ipping time Tr ipping time 50 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 Multiple of rated current 10 [ x In ] 0,3 0,2 0,1 1,05 1,35 2 3 4 5 Multiple of rated current 8 10 [ x In ] The above tripping characteristics apply to symmetrical overloads on the two poles. At asymmetric overloads on two pole types the tripping current will be increased by factor 1.05 (TC-2). Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [°C] Correction factor –25 0.79 –20 0.81 0 0.90 +23 1.00 +40 1.03 +50 1.04 +60 1.06 * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example: Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at +60 °C ambient temperature: Order code (Order example) Type Order code TA35 6135 C B D W F 1 2 0 C 0 see table 1 Please note that Schurter will establish an internal part number for logistics use in addition to the order code. The format of this internal part number is, for example: 6135.xxxx.xxxx Packaging unit Wiring 1 wired 0 unwired . 0 2 1 0 Terminals 1 Quick connect 6.3 x 0.8 mm Mounting 2 Snap-in s = 1.5 mm 3 Snap-in s = 2.0 mm 4 Snap-in s = 2.5 mm 5 Snap-in s = 3.0 mm 0 Protection class 1 40 Pcs Connectors 10 A +60 °C 1.06 10 A x 1.06 = 10.6 A 6135 Power entry modules without line filter www.schurter.com/pg05 Accessories Description Assorted Covers Rear Cover 0859.0074 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 Appliance Outlet further types to 6135 Connector Overview complete IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 IEC Connector C13, Rewireable, Angled 4013 Connector further types to 6135 ... Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to 6135 ... The specifications, descriptions and illustrations indicated in this document are based on Connectors current information. All content is subject to modifications and amendments.