SCHURTER TA35

6135
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole
C14
70° C
Description
Characteristics
-Panel Mount:
Snap-in version from front side
-2 Functions:
Appliance Inlet, Protection class I, Circuit breaker type TA35, 2-pole
-Quick connect terminal 6.3 x 0.8 mm
-Alternative: version for 16 A (20 A) 6136 -Substitute for type 7764 -Unwired
-Switch non-illuminated or illuminated
Thermal overload protection
-Qualified for use in equipment according IEC/EN 60950
Other versions on request
-Pre-wired version
-Quick-connect terminals 4.8 x 0.8 mm
-Protection class II, 70°C
Approvals
References
-VDE License Number: 40023066
-UL License Number: E96454
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, Distributor-StockCheck, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 60 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Snap-in1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
Circuit Breakers
Connectors
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated.
Conditional short circuit Inc:
2000 A
6135
Power entry modules without line filter
www.schurter.com/pg05
Dimensions
65.4 mm
10.6
31.8
+0.20
0
+0.20
0
59
65.4
27.4
3.2
58.8 x 27.2
30
6
max. R 0.2
S ± 0.05
R3
28.4
Diagrams
L
L' P1
2)
PE
PE'
TA35
1)
N
N' P2
1) Line
2) Load
Connectors
6135
Power entry modules without line filter
www.schurter.com/pg05
ORDER CODE
Table 1 Selection for type TA35
Switch
Switch
1
2
LINE
LINE
LOAD
LOAD
CBT
without
illumination
illuminated
Order example
2-pole
Number of switched poles
Number of protected poles
CBD
W
F
120
C0
CBD
C12
C14
240 V
120 V
TA35-
No other
features
C32
C34
Other versions on request
Colours
Switch front
W
B
3
4
6
Rocker
black
black
black
black
black
non-illuminated
illuminated
white
black
–
–
–
–
–
red transparent
green transparent
orange transparent
Other colours on request
Rocker legend
0
K
printed
L
printed
l
M printed
OFF OFF
printed
white
0
l
H
Colour of print
white
0
embossed
l
F
ON
Illustration
ON
Surface
black
black
Other legends on request
Position of the rocker
legend e.g. F
Rated current In (A)
In
Code
In
Code
1,0
2,0
4,0
5,0
6,0
J10
J20
040
050
060
8,0
10,0
12,0
15,0
080
100
120*
150*
Other rated currents on request
*) UL / CSA only
Connectors
6135
Power entry modules without line filter
www.schurter.com/pg05
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10'000
Tripping characteristics
In > 3 ... 15 A
Type p
Rated current
Ambient temp.
60
[ min ] [ sec ]
10'000
TA35
<3A (TC-1, TC-2)
+23 °C
60
2`000
30
20
20
1`000
10
500
TA35
> 3–15A (TC-1, TC-2)
+23 °C
2`000
30
1`000
10
Type
Rated current
Ambient temp.
500
5
5
200
200
100
100
1
1
50
20
20
10
10
5
5
2
2
1
1
0,5
0,5
Tr ipping time
Tr ipping time
50
0,3
0,2
0,1
1,05 1,35
2
3
4
5
8
Multiple of rated current
10
[ x In ]
0,3
0,2
0,1
1,05 1,35
2
3
4
5
Multiple of rated current
8
10
[ x In ]
The above tripping characteristics apply to symmetrical overloads on the two poles.
At asymmetric overloads on two pole types the tripping current will be increased by factor 1.05 (TC-2).
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for lower or higher ambient temperature,
use a correction factor from the table below.
* Ambient
temperature [°C]
Correction factor
–25
0.79
–20
0.81
0
0.90
+23
1.00
+40
1.03
+50
1.04
+60
1.06
* Temperature must be measured at the rear of the breaker
next to the terminals after equipment operating temperature has been reached.
Example:
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at +60 °C
ambient temperature:
Order code (Order example)
Type
Order code TA35
6135
C B D W F 1 2 0 C 0
see table 1
Please note that Schurter will establish an
internal part number for logistics use in
addition to the order code. The format of
this internal part number is, for example:
6135.xxxx.xxxx
Packaging unit Wiring
1 wired
0 unwired
. 0 2 1 0
Terminals
1 Quick connect 6.3 x 0.8 mm
Mounting
2 Snap-in s = 1.5 mm
3 Snap-in s = 2.0 mm
4 Snap-in s = 2.5 mm
5 Snap-in s = 3.0 mm
0 Protection class 1
40 Pcs Connectors
10 A
+60 °C
1.06
10 A x 1.06 = 10.6 A
6135
Power entry modules without line filter
www.schurter.com/pg05
Accessories
Description
Assorted Covers
Rear Cover
0859.0074
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
Appliance Outlet further types to 6135
Connector Overview complete
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
IEC Connector C13, Rewireable, Angled
4013
Connector further types to 6135
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to 6135
...
The specifications, descriptions and illustrations indicated in this document
are based on
Connectors
current information. All content is subject to modifications and amendments.