SECOS KBP210G

KBP2005G ~ KBP210G
VOLTAGE 50V ~ 1000V
Elektronische Bauelemente
2 AMP Bridge Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen-free.
0.600 (15.24)
0.118 x 45
(3.0)
o
0.560 (14.22)
0.460 (11.68)
FEATURES
0.500 (12.70)
0.460 (11.68)
0.420 (10.67)
. Surge overload rating – 60 amperes peak
. Ideal for printed circuit board
. Plastic material has underwrites laboratory
0.60
(15.24)
MIN.
Flammability classification 94V-0
. Mounting position: Any
0.50 (12.7) Min.
0.060
(1.52)
MAX.
0.034 (0.86)
0.028 (0.76)
0.160 (4.1)
0.140 (3.6)
0.053 (1.35)
0.045 (1.14)
0.200 (5.08)
0.180 (4.57)
Dimensions in inches and ( millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Resistive or inductive load, 60Hz,
For capacitive load, derate current by 20%.
o
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward
o
Rectified Output Current @ TA=50 C
Peak Forward Surge Current, 8.3 ms single
half Sine-wave superimposed
on rated load
Maximum Forward Voltage Drop
Per Bridge Element at 1.0A Peak
Maximum Reverse Current at Rated
DC Blocking Voltage per Element
Maximum Reverse Current at Rated
o
DC Blocking Voltage per Element @ TC=100 C
Typical Junction Capacitance
Operating and Storage Temperature Range
http://www.SeCoSGmbH.com/
01-Jun-2006 Rev. B
SYMBOL
KBP2005G KBP201G KBP202G KBP204G KBP206G KBP208G KBP210G
Unit
I(AV)
2.0
A
IFSM
60
A
VF
1.1
V
10
uA
1.0
mA
VRRM
VRMS
VDC
IR
50
35
50
100
70
100
200
140
200
400
280
400
Cj
25
TJ, TSTG
- 55 ~ + 150
600
420
600
800
560
800
1000
700
1000
V
V
V
pF
o
C
Any changing of specification will not be informed individual
Page 1 of 2
KBP2005G ~ KBP210G
VOLTAGE 50V ~ 1000V
Elektronische Bauelemente
2 AMP Bridge Rectifiers
ƔRATING AND CHARACTERISTIC CURVES
Fig. 1 — Derating Curve
Output Rectified Current
60
60 HZ
Resistive or
Inductive Load
1.5
P.C.B. Mounted
with 0.47 x 0.47"
(12 x 12mm)
Copper Pads
Capacitive Load
I(pk)
5.0
=
10
I(AV)
(Per Leg) 20
0.5
0
20
Peak Forward Surge Current (A)
Average Forward Output Current (A)
2.0
1.0
Fig. 2 — Maximum Non-Repetitive
Peak Forward Surge Current Per Leg
TJ = 150°C
Single Sine-Wave
(JEDEC Method)
50
40
30
20
10
1.0 Cycle
0
40
60
80
100
120
140
Ambient Temperature (°C)
Number of Cycles at 60 HZ
Fig. 3 — Typical Forward
Characteristics Per Leg
Fig. 4 — Typical Reverse Leakage
Characteristics Per Leg
20
100
Instantaneous Reverse Current (µA)
Instantaneous Forward Current (A)
100
10
1
160 170
10
1
TJ = 25°C
Pulse Width = 300µs
1% Duty Cycle
0.1
0.01
TJ = 125°C
10
1
0.1
TJ = 25°C
0.01
0
0.6
0.4
0.2
1.0
0.8
1.2
1.4
Instantaneous Forward Voltage (V)
TJ = 100°C
0
20
40
60
80
100
Percent of Rated Peak Reverse Voltage (%)
Fig. 5 — Typical Junction
Capacitance Per Leg
Junction Capacitance (pF)
100
TJ = 25°C
f = 1.0MHZ
Vsig = 50mVp-p
10
1
0.1
1
10
100
Reverse Voltage (V)
http://www.SeCoSGmbH.com/
01-Jun-2006 Rev. B
Any changing of specification will not be informed individual
Page 2 of 2