SECOS RS206

RS201L THRU RS207L
VOLTAGE 50V ~ 1000V
2.0AMP Single Phase Bridge Rectifiers
Elektronische Bauelemente
RoHS Compliant Product
A suffix of ā€œ-Cā€ specifies halogen-free.
RS-2
.510(13.0)
.472(12.0)
FEATURES
.50
MIN.
(12.7)
.035(0.9)
.028(0.7)
DIA.
* Ideal for printed circuit board
* Low forward voltage
.160(4.1)
SPACING
.140(3.6)
* Low leakage current
.260(6.5)
.240(6.1)
.730(18.5)
.690(17.5)
* Polarity: marked on body
.125
(3.2)
* Mounting position: Any
Dimensions in inches and (millimeters)
* Weight: 2.74 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
RS201 RS202 RS203 RS204 RS205 RS206
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
RS207 UNITS
1000
700
1000
V
V
V
.375"(9.5mm) Lead Length at Ta=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
2.0
A
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 2.0A D.C.
Maximum DC Reverse Current
Ta=25 C
50
1.1
10
A
V
µA
500
-65 ~ +125
-65 ~ +150
µA
at Rated DC Blocking Voltage
Operating Temperature Range, TJ
Storage Temperature Range, TSTG
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Ta=100 C
C
C
Any changing of specification will not be informed individual
Page 1 of 2
RS201L
THRU
RS207L
VOLTAGE 50V ~ 1000V
2.0AMP Single Phase Bridge Rectifiers
Elektronische Bauelemente
RATING AND CHARACTERISTIC CURVES (RS201 THRU RS207)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
1.2
2.0
1.6
Single Phase
1.2
Half Wave 60Hz
Resistive Or Inductive Load
0.8
0.4
0
0
25
50
75
100 125
150
175
CASE TEMPERATURE,( C)
PEAK FORWARD SURGE CURRENT,(A)
AVERAGE FORWARD CURRENT,(A)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
50
40
30
8.3ms Single Half
Tj=25 C
Sine Wave
20
JEDEC method
10
0
1
5
50
10
100
FIG.3-TYPICAL FORWARD
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
CHARACTERISTICS
50
50
10
10
REVERSE LEAKAGE CURRENT, (mA)
INSTANTANEOUS FORWARD CURRENT,(A)
NUMBER OF CYCLES AT 60Hz
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
0.1
3.0
1.0
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
FORWARD VOLTAGE,(V)
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
1.2
1.4
.01
0
20
40
60
80
100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
Any changing of specification will not be informed individual
Page 2 of 2