SECOS RS801

RS801 THRU RS807
VOLTAGE 50V ~ 1000V
8.0AMP Single Phase Bridge Rectifiers
Elektronische Bauelemente
RoHS Compliant Product
A suffix of ā€œ-Cā€ specifies halogen-free.
RS-8
.15FX.23L
(3.8FX5.7L)
HOLE THRU
.935(23.7)
.895(22.7)
.700(17.8)
.660(16.8)
.780(19.8)
.740(18.8)
AC
FEATURES
+
1.00
MIN.
(25.4)
.052(1.3)
.048(1.2)
DIA.
* Ideal for printed circuit board
.220(5.6)
SPACING
.180(4.6)
.078
(2.0)
* Low forward voltage
* Low leakage current
.280(7.1)
.268(6.8)
* Polarity: marked on body
Dimensions in inches and (millimeters)
* Mounting position: Any
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
RS801 RS802 RS803 RS804 RS805 RS806 RS807 UNITS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
V
V
V
.375"(9.5mm) Lead Length at Tc=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
8.0
A
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 8.0A D.C.
Maximum DC Reverse Current
Ta=25 C
300
1.0
10
A
V
µA
250
-55 ~ +150
-55 ~ +150
mA
at Rated DC Blocking Voltage
Operating Temperature Range, TJ
Storage Temperature Range, TSTG
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Ta=100 C
C
C
Any changing of specification will not be informed individual
Page 1 of 2
RS801 THRU RS807
VOLTAGE 50V ~ 1000V
8.0AMP Single Phase Bridge Rectifiers
Elektronische Bauelemente
RATING AND CHARACTERISTIC CURVES (RS801 THRU RS807)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
12
10
8
6
Single Phase
4
Half Wave 60Hz
Resistive Or Inductive Load
2
0
0
25
50
75
100 125
150
175
CASE TEMPERATURE,( C)
PEAK FORWARD SURGE CURRENT,(A)
AVERAGE FORWARD CURRENT,(A)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
250
200
150
8.3ms Single Half
Tj=25 C
Sine Wave
100
JEDEC method
50
0
1
5
50
10
100
FIG.3-TYPICAL FORWARD
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
CHARACTERISTICS
50
50
10
10
REVERSE LEAKAGE CURRENT, (mA)
INSTANTANEOUS FORWARD CURRENT,(A)
NUMBER OF CYCLES AT 60Hz
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
0.1
3.0
Tj=100 C
1.0
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
FORWARD VOLTAGE,(V)
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
1.2
1.4
.01
0
20
40
60
80
100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
Any changing of specification will not be informed individual
Page 2 of 2