SEMTECH_ELEC FR205

FR201 THRU FR207
FAST RECOVERY RECTIFIERS
Reverse Voltage – 50 to 1000 Volts
Forward Current – 2.0 Amperes
Features
• High Current Capability
• Fast switching for high efficiency
• Low Leakage.
• 2 ampere operation at TA = 55℃ with no thermal runaway
Mechanical Data
• Case: Molded plastic, DO-15
• Lead: Axial leads, solderable per MIL-STD-202, method 208 guaranteed.
• Polarity: Color band denotes cathode end
• Mounting Position: Any
Absolute Maximum Ratings and Characteristics
Ratings at 25℃ ambient temperature unless otherwise specified, single phase, half wave, 60Hz,
resistive or inductive load, for capacitive load, derate current by 20%.
Symbols
FR
FR
FR
FR
FR
FR
FR
201
202
203
204
205
206
207
Units
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
1000
Volts
Average forward rectified current .375” (9.5mm)
lead length at TA = 55℃
I(AV)
2
Amp
IFSM
70
Amps
VF
1.3
Volts
IR
500
Peak forward surge current
8.3ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum forward voltage
o
at 2A DC and 25 C
Maximum reverse current
TA = 25℃
at rated DC blocking voltage
TA = 100℃
Maximum reverse recovery time (Note 1)
Typical junction capacitance (Note 2)
5
Trr
150
µA
250
500
nS
CJ
35
pF
Typical thermal resistance (Note3)
RΘJA
22
℃/W
Operating and storage temperature range
TJ ,TS
-55 to +150
℃
1) Reverse recovery test conditions: IF = 0.5A, IR = 1A, Irr = 0.25A.
2) Measured at 1MHZ and applied reverse voltage of 4 VDC .
3) Thermal resistance junction to ambient and form junction to lead at 0.375” (9.5mm) lead length P.C.B. mounted.
SEMTECH ELECTRONICS LTD.
®
(Subsidiary of Semtech International Holdings Limited, acompany
listed on the Hong Kong Stock Exchange, Stock Code: 724)
Dated : 23/08/2004