SENSORTECHNICS ASDX005D44D

ASDX Series
Signal conditioned pressure transducers
FEATURES
GENERAL DESCRIPTION
· 0...1 to 0...100 psi,
0...±1 to 0...±100 psi
· Absolute, gage or
differential pressure
· 0.5...4.5 V ratiometric output
· Precision ASIC conditioning
· Temperature compensated
The amplified ASDX offers a high level
(4.0 V span) output on a very costeffective basis. This family is fully
calibrated
and
temperature
compensated using an on-board
ASIC. These sensors are intended for
use with non-corrosive, non-ionic
working fluids such as air and dry
gases.
Devices are available to measure
absolute, differential, and gage
pressures from 1 to 100 psi. The
absolute devices have an internal
vacuum reference and an output
voltage proportional to absolute
pressure. Differential devices allow
application of pressure to either side
of the sensing diaphragm and can be
used for gage or differential
measurements.
APPLICATIONS
· Medical instrumentation
· Barometry
· HVAC controls
· Pneumatic controls
All ASDX devices are accurate to
within ±2.0 %FSS. The devices are
characterized for operation from a
single 5 V supply. The sensor is
designed
and
manufactured
according to standards laid down in
ISO 9001.
ELECTRICAL CONNECTION
N/C
5 6 7
1
ASDX
2
+Vs
Note:
220 nF
Vout
15 nF
3
8 4
GND
Capacitor 220 nF required
between +Vs and GND and
15 nF between Vout and GND.
It is important to place the
capacitors as close to the pins
as possible!
Pins 4, 5, 6, 7 and 8 are internal
device connections and should
not be connected for any reason!
N/C
February 2009 / 530
1/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
PRESSURE SENSOR CHARACTERISTICS
Environmental specifications
Maximum ratings
Supply voltage VS
Output current
Sink
Source
Lead temperature (2 - 4 sec.)
Caution!
Temperature ranges
Compensated
Operating
Storage
4.75 V to 5.25 VDC
max. 6.50 VDC
2 mA
2 mA
0 to +85 °C
-20 to +105 °C
-40 to +125 °C
Vibration:
250 °C
10 g at 20 - 2000 Hz
Shock:
100 g for 11 ms
The sensor is not reverse polarity protected.
Incorrect applications of excitation voltage or ground to the wrong pin can cause electrical failure.
Application of supply voltage above the maximum can cause electrical failure.
PRESSURE RANGES SPECIFICATIONS
(VS = 5.0 VDC, TA = 25°C)
Part number
Pressure range
Burst pressure1
30
Sensitivity (typ.)
A S D X 015A 24R
0 to 15
A S D X 030A 24R
0 to 30
A S D X 100A 24R
0 to 100
150
0.040
ASDX001G24R / D44R
0 to 1
5
4.00
ASDX005G24R / D44R
0 to 5
20
0.80
ASDX015G24R / D44R
0 to 15
30
0.267
ASDX030G24R / D44R
0 to 30
60
0.133
ASDX100G24R / D44R
0 to 100
psi(a)
60
0.267
psi(a)
150
psi(g,d)
0.133
0.040
psi(g,d)
A S D X 001D 44D
0 to ±1
5
2.00
A S D X 005D 44D
0 to ±5
20
0.40
A S D X 015D 44D
0 to ±15
30
0.133
A S D X 030D 44D
0 to ±30
60
0.067
A S D X 100D 44D
0 to ±100
150
0.020
February 2009 / 530
V/psi
2/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
PERFORMANCE CHARACTERISTICS
0.5 to 4.5 V ratiometric output (VS = 5.0 VDC, TA = 25°C)
All ASDX...A24R, ...G24R, ...D44R
Characteristics
Zero pressure offset
Min.
Typ.
Max.
0.42
0.50
0.58
Full scale span (FSS)2
V
4.00
Full scale output
4.42
4.50
Total accuracy (0 to 85°C)3
4.58
±2.0
Sample rate
100
Response delay4
2.73
Units
%FSS
Hz
14.11
ms
Quantization step5
3
mV
Current consumption
6
mA
All ASDX...D44D
Characteristics
Zero pressure offset
Min.
Typ.
Max.
2.42
2.50
2.58
Full scale span (FSS)2
Units
4.00
V
Output
at max. specified pressure
4.42
4.50
4.58
at min. specified pressure
0.42
0.50
0.58
Total accuracy (0 to 85°C)3
±2.0
Sample rate
100
Response delay4
2.73
%FSS
Hz
14.11
ms
Quantization step5
3
mV
Current consumption
6
mA
February 2009 / 530
3/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
Total accuracy (%FSS)
TOTAL ACCURACY (-20 to +105°C)
3.0
2.0
1.0
0
-1.0
-2.0
-3.0
-20
0
20
40
60
85
105
Temperature (°C)
Specification notes:
1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing
die may fracture.
2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified
pressure. Span is ratiometric to the supply voltage.
3. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature
effects. Linearity is the measured deviation based on a straight line.
Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values.
4. Delay time between sampling and signal change at the output.
5. The smallest change in the output voltage, given any change in pressure.
February 2009 / 530
4/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
PHYSICAL DIMENSIONS
D4 package
1.27 typ
(0.050 typ)
16.89
(0.665)
7.87 typ
(0.310 typ)
13.97
(0.550)
3.63
(0.143)
High pressure port
2.29
(0.090)
3.38
(0.133)
8.13
8.89
(0.350) (0.320)
8.26 typ
(.325 typ)
Low pressure port
0.51 typ
(0.02 typ)
1.78
(0.070)
2.54 typ
(0.100 typ)
16.64 ±0.64
(0.655 ±0.025)
4.5
(0.177)
6.99
(0.275)
G2 package
3.15
(0.124)
1.27 typ
(0.050 typ)
13.97
(0.550)
16.89
(0.665)
4.9
(0.193)
2 ° typ
1.19 typ
(0.047 typ)
2.29 typ
(0.090 typ)
2.79 typ
(0.11 typ)
8.89
5.08 (0.350)
(0.200)
0.51 typ
(0.02 typ)
16.64 ±0.64
(0.655 ± 0.025)
4.5
(0.177)
2.54 typ
(0.100 typ)
A2 package
16.89
(0.665)
8.46
(0.333)
1.27 typ
(0.050 typ)
13.97
(0.550)
2.29 typ
(0.090 typ)
8.0 typ
(0.315 typ)
8.89
(0.350)
16.64 ±0.64
(0.655 ±0.025)
third angle projection
February 2009 / 530
4.5
(0.177)
0.51 typ
(0.02 typ)
2.54 typ
(0.100 typ)
dimensions in mm (inches)
5/6
www.sensortechnics.com
ASDX Series
Signal conditioned pressure transducers
ELECTRICAL CONNECTIONS
ASDX...D4...
ASDX...G24R
Vs (pin 1)
identifier
Vs (pin 1)
identifier
+Vs
Vout
GND
N/C
N/C
N/C
N/C
N/C
+Vs
Vout
GND
N/C
ASDX...A24R
N/C
N/C
N/C
N/C
Vs (pin 1)
identifier
N/C
N/C
N/C
N/C
Note:
Pins 4, 5, 6, 7 and 8 are internal
device connections and should
not be connected for any reason!
+Vs
Vout
GND
N/C
ORDERING INFORMATION
Pressure range
Absolute
Gage
Differential/Gage
0 to 1 psi
ASDX001G24R
A S D X 001D 44R
0 to 5 psi
ASDX005G24R
A S D X 005D 44R
0 to 15 psi
A S D X 015A 24R
ASDX015G24R
A S D X 015D 44R
0 to 30 psi
A S D X 030A 24R
ASDX030G24R
A S D X 030D 44R
0 to 100 psi
A S D X 100A 24R
ASDX100G24R
A S D X 100D 44R
0 to ±1 psi
A S D X 001D 44D
0 to ±5 psi
A S D X 005D 44D
0 to ±15 psi
A S D X 015D 44D
0 to ±30 psi
A S D X 030D 44D
0 to ±100 psi
A S D X 100D 44D
Other pressure ranges or calibrations are available on request
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising
out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
February 2009 / 530
6/6
www.sensortechnics.com