OMRON DCA1-5C10-B

Peripheral Devices
General-purpose Peripheral Devices
Peripheral Devices for DeviceNet Communications
Ordering Information
● General-purpose Models
Product
Appearance
Model
Specifications
DCN1-1NC
Cable wiring direction: Toward top
Cable lock direction: From top
Connector screw direction: From top
DCN1-1C
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From side
T-branch Tap for
1 branch line
154
Peripheral Devices
Provided with 3 parallel
connectors with screws
(XW4B-05C1-H1-D), standard
terminating resistor
DCN1-2C
Cable wiring direction: Toward top
Cable screw direction: From side
Connector screw direction: From top
DCN1-2R
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From top
Provided with 3 orthogonal
connectors with screws
(XW4B-05C1-VIR-D), standard
terminating resistor
DCN1-3NC
Cable wiring direction: Toward top
Cable lock direction: From top
Connector screw direction: From top
Provided with 5 parallel clamp
connectors with screws
(XW4G-05C1-H1-D), standard
terminating resistor
DCN1-3C
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From side
T-branch Tap for
3 branch lines
Power Supply Tap
Provided with 3 parallel
connectors with clamps
(XW4G-05C1-H1-D), standard
terminating resistor
Provided with 5 parallel
connectors with screws
(XW4B-05C1-H1-D), standard
terminating resistor
DCN1-4C
Cable wiring direction: Toward top
Cable screw direction: From side
Connector screw direction: From top
DCN1-4R
Cable wiring direction: Toward side
Cable screw direction: From top
Connector screw direction: From top
DCN1-1P
Tap provided with 2 connectors, standard terminating resistor, and fuse
Provided with 5 orthogonal clamp
connectors with screws
(XW4B-05C1-VIR-D), standard
terminating resistor
Product
Appearance
Model
Specifications
XW4G-05C1-H1-D
Parallel clamp connector with screws
Connector insertion and wiring both performed horizontally.
XW4G-05C4-TF-D
Parallel multi-branching clamp connector with screws
Connector insertion and wiring performed in same direction.
XW4B-05C1-H1-D
Parallel connector with screws
Connector insertion and wiring performed in same direction.
XW4B-05C4-T-D
Parallel, screw-less, multi-branching connector
Connector insertion and wiring performed in same direction.
XW4B-05C4-TF-D
Parallel, multi-branching connector with screws
Connector insertion and wiring performed in same direction.
XW4B-05C1-VIR-D
Orthogonal connector with screws
Connector insertion and wiring performed at a right angle.
Thin
Cables
DCA1-5C10(-B)
Outer diameter:
Length:
DCA1-5C10-B:
DCA1-5C10:
7.00 mm
100 m
Cable color: Blue
Cable color: Gray
Thick
Cables
DCA2-5C10(-B)
Outer diameter:
Length:
DCA2-5C10-B:
DCA2-5C10:
11.6 mm
100 m
Cable color: Blue
Cable color: Gray
DRS1-T
Resistance of 121 Ω
Connectors
DeviceNet
Standard
Cables
Terminal-block
Terminator
Peripheral Devices
155
● Peripheral Devices for Flat Cables
Product
Appearance
Model
Specifications
Connector for Flat
Cable
DCN4-SF4D
Connector with lock screws for crimping flat cable
Conversion Connector
for Standard Thin
Cable and Flat Cable
DCN4-BR4D
Used as a set with a DCN4-TR4 when Thin Cable is branched on a branch
line.
Power Supply
Terminal Block with
Terminating
Resistance for Flat
Cable
DCN4-TP4D
Can be used to supply communications power from terminals when Flat
Cable is used.
DCN4-TR4
Flat Connector Socket
Used as a set with a DCN4-BR4 Flat Connector Plug in the following
applications.
• Extending the trunk line
• T-branching the trunk line into branch lines
Used alone in the following applications.
• Connecting a DCN4-TM4 Terminating Resistor to the trunk line
Flat Connector Plug
DCN4-BR4
Used as a set with a DCN4-TR4 Flat Connector Socket in the following
applications.
• Extending the trunk line
• T-branching the trunk line into branch lines
Terminating Resistor
DCN4-TM4
Connector terminating resistor for flat cable. Attached to the DCN4-TR4 Flat
Connector Socket at the end of the trunk line.
Flat Cable
DCA4-4F10
Four-core flat cable (UL 2555)
Length: 100 m
Conductor diameters: 0.75 mm2 x 2, 0.5 mm2 x 2
Simple Manual Crimp
Tool
DWT-A01
Crimping tool for DCN4-TR4 Flat Connector Socket or DCN4-BR4 Flat
Connector Plug.
Specifications
● General-purpose Models (T-branch Taps)
Between main lines: 8 A (power supply line) and 2 A
(signal line)
Rated current
Between main and branch lines: 3 A (power supply line)
and 1 A (signal line)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min, leakage current: 1 mA max.
Ambient operating
temperature
0°C to 55°C
156
Peripheral Devices
Dimensions
(Unit: mm)
● General-purpose Models
T-branch Tap for 1 branch line
DCN1-1NC
(With Three Branching
Connectors)
Internal Circuit
74.5
67.5
20
45
TRUNK
LINE
20
14
TRUNK
LINE
1
5
4
5
4
5
4
3
2
1
3
2
1
3
2
1
Terminal No.
46
30.9
20.5
Mounting Dimensions
Two,
3.5±0.1 dia.
or M3
Terminator
connection
Name
1
V-
2
CAN L
3
DRAIN
4
CAN H
V+
5
14.15±0.1
74.5±0.1
T-branch Tap for 1 branch line
DCN1-1C
(With Three Branching
Connectors)
Internal Circuit
97
Main line
90
Note
5
4
CN1
3 2
Main line
1
5
4
CN2
3 2
1
15.5
45
4
2
15.5
1
7
Socket for terminator connection
2
3 4
CN3
CN4
5
Branch line
Terminal No.
31.27
20.5
Mounting Dimensions
Two,
3.5 dia.
or M3
14±0.3
Name
1
V-
2
CAN L
3
DRAIN
4
CAN H
V+
5
97±0.3
Note: When connecting a branch line to the main line, connect the main line to the connector
marked with an asterisk because the resistance between the asterisks is minimal.
T-branch Tap for 3 branch lines
DCN1-3NC
(With Five Branching
Connectors)
Internal Circuit
97
90
17
17
17
TRUNK
LINE
17
2.3
45
14
1
30.9
20.5
Mounting Dimensions
Two,
3.5±0.1 dia.
or M3
3
TRUNK
LINE
5
5
5
5
5
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
Terminal No.
46
2
Name
1
V-
2
CAN L
3
DRAIN
4
CAN H
V+
5
Terminator
connection
14±0.1
97±0.1
Peripheral Devices
157
T-branch Tap for 3 branch lines
DCN1-3C
(With Five Branching
Connectors)
Internal Circuit
142
Main line
Socket for
terminator
135
5
4
CN1
3 2
Main line
1
5
4
CN2
3 2
1
CN6
Note
4
2
15.5
45
15.5
1
2
3 4
CN3
5
1
2
3 4
CN4
5
1
2
3 4
CN5
5
7
Branch line
Terminal No.
31.27
20.5
Two,
3.5 dia.
or M3
Mounting Dimensions
14±0.3
Branch line
Name
1
V-
2
CAN L
3
DRAIN
4
CAN H
V+
5
Branch line
142±0.3
Note: When connecting a branch line to the main line, connect the main line to the connector
marked with an asterisk because the resistance between the asterisked portion is minimal.
Power Supply Tap
DCN1-1P
(With Two Branching
Connectors)
Internal Circuit
126.5
119.5
CN1
112.5
V−
L
S
H V+
F1
45
V+ V−
S
15.5
Two, 3.5 dia.
CN4
CN3
15.5
F2
V+' H'
Fuse
Socket for terminator
connection
Connectors on Cable side
S'
L' V−'
CN2
Terminal block on
power supply side
Terminal No.
45.3
30.9
29.9
V-
L
CAN L
S
DRAIN
H
V+
CAN H
V+
20.5
Mounting Dimensions
Two,
3.5 dia.
or M3
14±0.3
119.5±0.3
DRS1-T
(Terminal-block Terminator)
Mounting Dimensions
Two, 4.2 dia. or M4
30±0.2
30±0.2
Two, 4.4 dia.
20 max.
+0.1
6−0
20±0.15
41 max.
158
Peripheral Devices
21 max.
Name
V-
● Flat Cable
Connector for Flat Cable
DCN4-SF4D
Conversion Connector for Standard Thin Cable and
Flat Cable
DCN4-BR4D
30.20
(23)
21.3
36
8.3
18.14
1.45
12.64
11.1
9.2
9.5
9.2
9.5
20
38.55
27
Power Supply Terminal Block with Terminating Resistance
for Flat Cable
DCN4-TP4D
4.55
6
17
20.90
16.20
13.50
29
3
33.60
Flat Connector Socket
DCN4-TR4
Flat Connector Plug
DCN4-BR4
22
17
(23)
21.3
17.8
8.3
9.5
30.7
13.8
20
Peripheral Devices
159
I/O Peripheral Devices
■ I/O Connectors for Connector Terminals
●MIL Connectors
Applicable Connectors
Type
Model
Pressure-welded
Connectors with
Loose Wires
*
Remarks
XG4M-4030-T
Flat Cable Pressure-welded Connectors
Socket
XG5M-4032-N
Corresponding to 24 AWG
XG5M-4035-N
Corresponding to 28 to 26 AWG
Semicover
XG5S-2001
Hood Cover *
XG5S-4022
DeviceNet connectors for multi-drop wiring cannot be used with the Hood Cover.
Cable Models
Type
Model
Connected device
Applicable models
G79-I@@-@@-D1
DRT2-ID32ML
G79-M@@-@@-D1
DRT2-MD32ML
G79-O@@-@@-D1
Cable with Connectors (1:2)
G7TC/G70D/G70A
DRT2-OD32ML/DRT1-OD32ML-1
G79-I@@-@@-D2
DRT2-ID32ML-1
G79-M@@-@@-D2
DRT2-MD32ML-1
Cable with Connector (1:1)
XW2Z-C@@K
Cable with Loose Wires with Crimp Terminals
G79-Y@00C-D1
Cable with Loose Wires
G79-A@00C-D1
All models
--
Applicable Cables with Connectors
● Cables with Connectors (1-to-2 Connection)/G79-@@-@-D@
Cable length (mm)
Appearance
A
Model
A
B
500
250
G79-I50-25-D1
750
500
G79-I75-50-D1
500
250
G79-O50-25-D1
750
500
G79-O75-50-D1
500
250
G79-M50-25-D1
750
500
G79-M75-50-D1
500
250
G79-I50-25-D2
750
500
G79-I75-50-D2
500
250
G79-M50-25-D2
750
500
G79-M75-50-D2
(120)
B
Length without any bending
● Cables with Connectors (1-to-1 Connection)/XW2Z-C@@K
Appearance
Cable length (mm)
L
Model
250
XW2Z-C25K
500
XW2Z-C50K
● Cables with Crimp Terminals (at the End of Loose Wires)/G79-Y@C-D1
Appearance
Cable length (mm)
Terminal A
Terminal B
Connected
to device
300
160
Peripheral Devices
Model
1,000
G79-Y100C-D1
2,000
G79-Y200C-D1
5,000
G79-Y500C-D1
L
● Cables with Loose Wires/G79-A@C
Appearance
Cable length (mm)
Terminal A
Terminal B
Model
2,000
G79-A200C-D1
5,000
G79-A500C-D1
Connected
to device
300
L
Peripheral Devices
161
■ I/O Connectors for MULTIPLE I/O TERMINALs
Applicable Connectors
Type
Model
Housing
Chain terminal
Crimped
terminals
Molex connector
Loose terminal
Press-fit tool
Fujitsu connector
(16 points)
Fujitsu connector
(32 points)
OMRON
D-sub connector
Remark
Connectable model
50-57-9403
16-02-0069
Corresponding to 24 to 30 AWG
16-02-0086
Corresponding to 22 to 24 AWG
16-02-0096
Corresponding to 24 to 30 AWG
16-02-0102
Corresponding to 22 to 24 AWG
57036-5000
Corresponding to 22 to 26 AWG
57037-5000
Corresponding to 24to 30 AWG
Soldered terminals
FCN361J024-AU
Pressure-welded terminals
FCN367J024-AU/F
Crimped terminals
FCN363J024-AU
Soldered terminals
FCN361J040-AU
Pressure-welded terminals
FCN367J040-AU/F
Crimped terminals
FCN363J040-AU
Pulg
XM2A-2501
Hood
XM2S-2513
Digital I/O Units
GT1-ID16MX(-1)/GT1-OD16MX(-1)
Analog I/O Units
GT1-AD08MX/GT1-DA04MX
Digital I/O Units
GT1-ID32ML(-1)/GT1-OD32ML(-1)
Digital I/O Units
GT1-ID16DS(-1)/GT1-OD16DS(-1)
#4-40UNC inch screws
Applicable Cables with Connectors (Fujitsu Connectors)
I/O classification
Digital input, 16 points
Digital output, 16 points
Digital input, 32 points
Digital output, 32 points
Model
Connectable model
XW2Z-@@@A
Digital I/O Units
GT1-ID16ML(-1)
G79-@C
XW2Z-@@@A
Digital I/O Units
GT1-OD16ML(-1)
G79-@C
XW2Z-@@@B
Digital I/O Units
GT1-ID32ML(-1)
G79-I@C@
XW2Z-@@@B
Digital I/O Units
GT1-OD32ML(-1)
G79-O@C@
● Cables with Connectors (1-to1 Connection)/G79-@C
For Digital Input/Output (16 Points)
Appearance
Cable length (mm)
Model
L
1,000
G79-100C
1,500
G79-150C
2,000
G79-200C
3,000
G79-300C
5,000
G79-500C
● Cables with Connectors (1-to-2 Connection)/G79-O@C-@, G79-I@C-@
For Digital Input/Output (32 Points)
Appearance
Cable length (mm)
A
B
Length without any bending
Model
A
B
1,000
750
1,500
2,000
Input
Output
G79-I100C-75
G79-O100C-75
1,250
G79-I150C-125
G79-O150C-125
1,750
G79-I200C-175
G79-O200C-175
3,000
2,750
G79-I300C-275
G79-O300C-275
5,000
4,750
G79-I500C-475
G79-O500C-475
For Digital Input/Output (16 Points)
Appearance
Cable length (mm)
L
Model
500
XW2Z-050A
1,000
XW2Z-100A
1,500
XW2Z-150A
2,000
XW2Z-200A
3,000
XW2Z-300A
5,000
XW2Z-500A
500
XW2Z-050B
1,000
XW2Z-100B
1,500
XW2Z-150B
2,000
XW2Z-200B
3,000
XW2Z-300B
5,000
XW2Z-500B
For Digital Input/Output (32 Points)
Appearance
Cable length (mm)
L
162
Peripheral Devices
Model
■ I/O Connector for Programmable Slaves
Applicable Connector Terminal Conversion Units
Applicable cable
Connected product
Remarks
XW2D-20G6
Slim type
(with M3 screw terminals)
XW2B-20G4
Flat cable connectors
(with M3 terminal screws for flat-blade screwdriver)
XW2Z-@@@A
Applicable Cables with Connectors
● Cables with Connectors/XW2Z
For Digital Input/Output (16 Points)
Appearance
Cable length (mm)
L
Model
500
XW2Z-050A
1,000
XW2Z-100A
1,500
XW2Z-150A
2,000
XW2Z-200A
3,000
XW2Z-300A
5,000
XW2Z-500A
Peripheral Devices
163
Peripheral Devices for Environment-resistive Slaves
Peripheral Devices for DeviceNet Communications
Ordering Information
● Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors)
Product
Appearance
Model
Specifications
Sealed Assembling-type
Connector (male)
XS2G-D5S7
For communications (plug)
Sealed Assembling-type
Connector (female)
XS2C-D5S7
For communications (socket)
Sealed T-branch Connector
DCN2-1
For 1 branch line
DRS2-1
Plug
DRS2-2
Socket
DCA1-5CNC5W1
Length (L): 0.5 m
DCA1-5CN01W1
Length (L):
1m
DCA1-5CN02W1
Length (L):
2m
DCA1-5CN03W1
Length (L):
3m
DCA1-5CN05W1
Length (L):
5m
DCA1-5CN10W1
Length (L): 10 m
DCA1-5CNC5F1
Length (L): 0.5 m
DCA1-5CN01F1
Length (L):
1m
DCA1-5CN02F1
Length (L):
2m
DCA1-5CN03F1
Length (L):
3m
DCA1-5CN05F1
Length (L):
5m
DCA1-5CN10F1
Length (L): 10 m
DCA1-5CNC5H1
Length (L): 0.5 m
DCA1-5CN01H1
Length (L):
1m
DCA1-5CN02H1
Length (L):
2m
DCA1-5CN03H1
Length (L):
3m
DCA1-5CN05H1
Length (L):
5m
DCA1-5CN10H1
Length (L): 10 m
DCA1-5CNC5P1
Panel-mounting connector (socket) with 0.5-m cable
XS2P-D522-2
Panel-mounting connector socket
DCA1-5CNC5M1
Panel-mounting connector (plug) with 0.5-m cable
XS2M-D524-4
Panel-mounting connector (plug) with solder-cup terminals
Sealed Connector with
Terminating Resistor
L
Cables with Sealed
Connectors
L
L
50 mm
50 mm
Cable with connectors on both ends
Cable with connector on one end (socket)
Cable with connector on one end (plug)
Shielded Panel-mounting
Connectors (female)
Shielded Panel-mounting
Connectors (male)
Waterproof cover (for
socket)
XS2Z-22
Used to cover an unused connector section
Dust cover (for socket)
164
Peripheral Devices
XS2Z-15
● Environment-resistive Models (for Thin Wires and M12 Micro Connectors)
Product
Appearance
Model
Sealed T-branch Connector
Sealed Assembling type
Connector (female)
L
Connectors with Shielded
Cables
L
L
50 mm
50 mm
Specifications
DCN2-1S
For 1 branch line
DRS2-1S
Plug
DRS2-2S
Socket
DCA1-5CSC5W1
Length (L): 0.5 m
DCA1-5CS01W1
Length (L):
1m
DCA1-5CS02W1
Length (L):
2m
DCA1-5CS03W1
Length (L):
3m
DCA1-5CS05W1
Length (L):
5m
DCA1-5CS10W1
Length (L): 10 m
DCA1-5CSC5F1
Length (L): 0.5 m
DCA1-5CS01F1
Length (L):
1m
DCA1-5CS02F1
Length (L):
2m
DCA1-5CS03F1
Length (L):
3m
DCA1-5CS05F1
Length (L):
5m
DCA1-5CS10F1
Length (L): 10 m
DCA1-5CSC5H1
Length (L): 0.5 m
DCA1-5CS01H1
Length (L):
1m
DCA1-5CS02H1
Length (L):
2m
DCA1-5CS03H1
Length (L):
3m
DCA1-5CS05H1
Length (L):
5m
DCA1-5CS10H1
Length (L): 10 m
DCN2-S4C5H1
4 ports, 0.5-m cable
DCN2-S8C5H1
8 ports, 0.5-m cable
Cable with connectors on both ends
Cable with connector on one end (socket)
Cable with connector on one end (plug)
Shielded Branch Relay Box
Peripheral Devices
165
● Environment-resistive Models for Thick Wires with 7/8-16UN Mini Connectors
Product
Appearance
Model
Specifications
DCN3-11
T-branch Connector
DCN3-12
T-branch Connector (Branch connector is M12.)
DRS3-1
Plug
DCA2-5CN01W1
Length (L): 1 m
DCA2-5CN02W1
Length (L): 2 m
DCA2-5CN05W1
Length (L): 5 m
DCA2-5CN10W1
Length (L): 10 m
DCA2-5CN01F1
Length (L): 1 m
DCA2-5CN02F1
Length (L): 2 m
DCA2-5CN05F1
Length (L): 5 m
DCA2-5CN10F1
Length (L): 10 m
DCA2-5CN01H1
Length (L): 1 m
DCA2-5CN02H1
Length (L): 2 m
DCA2-5CN05H1
Length (L): 5 m
DCA2-5CN10H1
Length (L): 10 m
DCA1-5CN01W5
Length (L): 1 m
DCA1-5CN02W5
Length (L): 2 m
DCA1-5CN05W5
Length (L): 5 m
DCA1-5CN10W5
Length (L): 10 m
Panel-mounting Connector
(female)
DCA2-5CNC5P1
Panel-mounting connector (socket) with 0.5-m cable
Panel-mounting Connector
(male)
DCA2-5CNC5M1
Panel-mounting connector (plug) with 0.5-m cable
Panel-mounting Connector
(male)
XS4M-D521-1
Panel-mounting connector (plug)
DIP terminals
Sealed T-branch Connector
Sealed Connector with
Terminating Resistor
L
50
mm
L
Cables with Sealed
Connectors
50
mm
L
L
Waterproof Cap (for Plug)
-
XS4Z-11
Waterproof Cap (for
Socket)
-
XS4Z-12
166
Peripheral Devices
Cable with connectors on both ends
Cable with connector on one end (socket)
Cable with connector on one end (plug)
Cable with connectors on both ends
Thin cable
M12 socket
Used to cover an unused connector section.
Specifications
● Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors)
Type
Connectors with Cables
DCA1-5CN@@@1
Item
T-branch Connector
DCN2-1
Connectors with Terminating
Resistor
DRS2-@
Assembling-type Connector
XS2@-D5S7
Rated current
3A
Rated voltage
125 VDC
Contact resistance
(connector)
40 mΩ max. (at 20 mVDC max. and 100 mA max.)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
(connector)
1,500 VAC for 60 seconds (leakage current: 1 mA max.)
Ambient operating
temperature
-20°C to 65°C
Storage temperature
range
-25°C to 70°C
Degree of protection
IEC IP67
Insertion durability
200 times
Cable strength
98 N for 15 s
Vibration resistance
No current interruptions of more than 1 µs while performing simple vibrations at either 10 to 500 Hz with 1.52-mm full amplitude or at acceleration
100 m/s2, whichever is smaller
--
● Environment-resistive Models (for Thin Wires and M12 Micro Connectors)
Type
Connectors with Cables
DCA1-5CS@@@1
Item
Connectors with Terminating
Resistor
DRS2-@S
T-branch Connector
DCN2-1S
Branch Relay Box
DCN2-S@C5H
Rated current
3A
Rated voltage
125 VDC
Contact resistance
(connector)
40 mΩ max. (at 20 mVDC max. and 100 mA max.)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
(connector)
1,500 VAC for 60 seconds (leakage current: 1 mA max.)
Ambient operating
temperature
-20°C to 65°C
Storage temperature
range
-25°C to 70°C
Degree of protection
IEC IP67
Insertion durability
200 times
Cable strength
98 N for 15 s
Vibration resistance
No current interruptions of more than 1 µs while performing simple vibrations at either 10 to 500 Hz with 1.52-mm full amplitude or at acceleration
100 m/s2, whichever is smaller
Lock strength
Pulling: 100 N/15 s, Rotating: 1 N·m/15 s
Lock force
0.1 to 0.25 N·m
1,000 VAC for 60 seconds
--
● Environment-resistive Models for Thick Wires with 7/8-16UN Mini Connectors
Item
Type
Connectors with
Thick Cables
DCA2-5CN@@@1
Connectors with
Thin Cables
DCA1-5CN@@W5
Rated current
8A
3A
Rated voltage
125 VDC
Contact resistance
(connector)
30 mΩ max. (at 20 mVDC max. and 100 mA max.)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
(connector)
1,500 VAC for 60 seconds (leakage current: 1 mA max.)
Ambient operating
temperature
-20°C to 65°C
Storage temperature
range
-25°C to 70°C
Degree of protection
IEC IP67
Insertion durability
200 times
Cable strength
98 N for 15 s
Vibration resistance
No current interruptions of more than 1 µs while performing simple vibrations at either 10 to 500 Hz with 1.52-mm full amplitude or at acceleration 100
m/s2, whichever is smaller
*
T-branch
Connector
DCN3-11
8A
T-branch
Connector
DCN3-12
3A *
Connectors with
Terminating Resistor
DRS3-1
Panel Mounting
Connector
DCA2-5CNC5P1
Panel Mounting
Connector
XS4M-D521-1
8A
--
98 N for 15 s
--
The rated current between thick wires is 8 A.
Peripheral Devices
167
Dimensions
● Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors)
Cables with Connectors on Both Ends
DCA1-5CN@@W1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
L (cable length)
2
44.7
1
3
4
5
3
5
1
2
4
M12
M12
Cables with Connector on Single End (Socket)
DCA1-5CN@@F1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
L (cable length)
1
40.7
2
5
3
4
M12
50
Cables with Connector on Single End (Plug)
DCA1-5CN@@H1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
L (cable length)
2
44.7
1
5
3
4
50
M12
T-branch Connector
DCN2-1
Connections Diagram
Wiring
Plug CN0 (IN)
Socket CN2 (OUT)
1
2
3
4
5
1
2
3
4
5
Terminal No.
1
2
3
4
5
1 2 3 4 5
Name
SHIELD
V+
VCAN H
CAN L
Connectors with Terminating Resistance
Wiring
DRS2-1 (Plug)
Terminal No.
DRS2-2 (Socket)
1
2
3
4
5
Socket CN1 (OUT)
24.7
13.6
4.5 dia.
8 dia. (Countersinking: 2)
12
5
CAN H :
CAN L :
44.7
4
4
5
2
1
10
32.1
14.9 dia.
CN0
3
1
2
CN2
13.6
CN1
1
2
5
3
1
2
5
3
4
M12
18
Note: The diagram shows the DRS2-1 (plug).
4
168
3
Peripheral Devices
121 Ω
Note: Terminating resistance (121 Ω) is
connected between terminals 4
and 5.
(56)
17.7
Name
DRAIN : NC
V+
: NC
V: NC
8.5 13.6
dia. dia.
Panel-mounting Connector (Socket) with 0.5 m Cable
DCA1-5CNC5P1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
Rubber bushing
M16 nut
Heat-shrinking tube
2
1
5
3
4
500
XS2P-D522-2
50
Panel-mounting Connector (Socket), Solder-cup Terminals
XS2P-D522-2
M16 nut
7
2
1
Panel Cutout Dimensions
M16 × 1
3
1.5
17
2
3
5
16 dia.+0.3
0
7+0.2
0
5
14 dia.
3
4
1
20 dia.
4
M12 × 1
6.8
8.7
20.5
2.5
3
5
25.5
]
Panel-mounting Connector (Plug) with 0.5 m Cable
DCA1-5CNC5M1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
Rubber bushing
M16 nut
Heat-shrinking tube
1
2
5
3
4
XS2M-D524-4
500
50
Panel-mounting Connector (Socket), Solder-cup Terminals
XS2M-D524-4
M16 nut
3
5 dia.
7
2
1
M12×1
Panel Cutout Dimensions
M16 × 1
Sealing rubber
17
4
5
1
16 dia.+0.1
0
7+0.1
0
5
16 dia.
3
4
3
M12×1
1.5
1.5
6.5 8.7
18.7
27.7
2
20 dia.
3.5
4.5
5.5
Peripheral Devices
169
● Environment-resistive Models (for Thin Wires and M12 Micro Connectors)
Cables with Connectors on Both Ends
DCA1-5CS@@W1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
L (cable length)
2
44.7
1
3
4
5
5
3
1
2
4
M12
M12
Cables with Connector on Single End (Socket)
DCA1-5CS@@F1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
L (cable length)
1
40.7
2
5
3
4
M12
50+20
−10
]
Cables with Connector on Single End (Plug)
DCA1-5CS@@H1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
L (cable length)
2
44.7
1
5
3
4
50+20
−10
M12
T-branch Connector
DCN2-1S
Connections Diagram
Wiring
Plug CN0 (IN)
Socket CN2 (OUT)
1
2
3
4
5
1
2
3
4
5
Terminal No.
1
2
3
4
5
1 2 3 4 5
Name
SHIELD
V+
VCAN H
CAN L
Connectors with Terminating Resistance
Wiring
DRS2-1S (Plug)
Terminal No.
DRS2-2S (Socket)
1
2
3
4
5
Socket CN1 (OUT)
17.7
5
(56)
24.7
12
Name
DRAIN : NC
V+
: NC
V: NC
CAN H :
CAN L :
Note: Terminating resistance (121 Ω) is
connected between terminals 4
and 5.
4.5 dia.
13.6
8 dia. (Countersinking: 2)
4
4
5
2
1
44.7
10
32.1
3
1
2
14.9 dia.
CN0
CN2
13.6
CN1
3
1
2
5
3
4
M12
1
2
5
18
Note: The diagram shows the DRS2-1 (plug).
4
170
3
Peripheral Devices
121 Ω
8.5 13.6
dia. dia.
Shielded Branch Relay Box with Four Ports
DCN2-S4C5H1
73
5 1
23
4
2
1
33
54
5
27
3
4.5 dia.
4
M12
4.5
9
4.5 dia.
9
30.5
27
82
500+60
−0
9
9
20
13.5
Connections Diagram
PORT 1 PORT 2 PORT 3 PORT 4
1
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
5
Name
DRAIN
V+
VCAN H
CAN L
5
1
Shielded Branch Relay Box with Eight Ports
DCN2-S8C5H1
23
73
5 1
4
2
1
33
54
5
27
3
4
M12
4.5
9
4.5
dia.
dia.
27
4.5 dia.
9
27
127
27
30.5
500+60
−0
9
9
20
13.5
Connections Diagram
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8
1
5
Wiring
Terminal No. Color
1
2
Red
3
Black
4
White
5
Blue
Name
DRAIN
V+
VCAN H
CAN L
5
1
Peripheral Devices
171
● Environment-resistive Models for Thick Wires with 7/8-16UN Mini Connectors
Thick Cable with Connectors on Both Ends (5 Conductors for Communications)
DCA2-5CN@@W1
Wiring
L
1
61.2
62.5
5
Terminal
Color
No.
1
5
12 dia.
2
4
3
26 dia.
4
26 dia.
3
2
Name
1
-
DRAIN
2
Red
V+
3
Black
V-
4
White
CAN H
5
Blue
CAN L
Thick Cable with Connector Socket on One End (5 Conductors for Communications)
DCA2-5CN@@F1
Wiring
5
61.2
1
Terminal
Color
No.
12 dia.
26 dia.
4
2
3
L
50
Name
1
-
DRAIN
2
Red
V+
3
Black
V-
4
White
CAN H
5
Blue
CAN L
Thick Cable with Connector Plug on One End (5 Conductors for Communications)
DCA2-5CN@@H1
Wiring
1
62.5
5
Terminal
Color
No.
12 dia.
26 dia.
2
4
3
L
50
Name
1
-
DRAIN
2
Red
V+
3
Black
V-
4
White
CAN H
5
Blue
CAN L
Thin Cable with Connectors on Both Ends (5 Conductors for Communications)
DCA1-5CN@@W5
Wiring
L
1
5
Terminal
Color
No.
40.7
62.5
1
2
6 dia.
14.9 dia.
2
4
3
4
26 dia.
Thin Cable with Panel-mounting Connector Socket on One End
(5 Conductors for Communications)
DCA2-5CNC5P1
41
27
1.7
5
1
5
3
Name
1
-
DRAIN
2
Red
V+
3
Black
V-
4
White
CAN H
5
Blue
CAN L
Panel Cutout Dimensions
20 dia. 2
L
+0.1
0
50
25
15
33 min.
12 dia.
Wiring
4
3
Terminal
Color
No.
2
M20 × 1.5
Note: A rubber seal and nut for panel mounting are included.
172
Peripheral Devices
Name
-
DRAIN
2
Red
V+
3
Black
V-
4
White
CAN H
5
Blue
CAN L
1
Panel-mounting Connector (Plug) with 0.5 m Cable
DCA2-5CNC5M1
46
500
4
Wiring
50
25
Terminal
Color
No.
1
5
15
1
5
2
12 dia.
4
3 (sequence pin)
M20 × 1.5
O-ring
2
Red
3
Black
V+
V-
4
White
CAN H
5
Blue
CAN L
74.7
25.4
5
1
5
4
4
26 dia.
2
D4N3-11
14.6
3
CN0
Connections Diagram
DRAIN
2
Note: A nut is included.
T-branch Connector (5 Conductors for Communications,
Thick Wire Branch Line)
DCN3-11
1
Name
CN2
3
41.7
CN1
Wiring
Plug CN0 (IN)
Socket CN2 (OUT)
Terminal No.
Name
1
2
3
4
5
1
2
3
4
5
1
DRAIN
2
V+
3
V-
4
CAN H
5
CAN L
4
3
1 2 3 4 5
28.5
5
2
1
Socket CN1 (OUT)
T-branch Connector (5 Conductors for Communications,
Thin Wire Branch Line)
DCN3-12
1
2
74.7
5
1
5
4
4
26 dia.
2
D4N3-12
14.6
3
CN0
CN2
3
37.6
5.5 dia.
CN1
Connections Diagram
Wiring
Plug CN0 (IN)
Socket CN2 (OUT)
Terminal No.
Name
1
2
3
4
5
1
2
3
4
5
1
DRAIN
2
V+
1 2 3 4 5
3
V-
4
CAN H
5
CAN L
25.4
3
4
5
28.5
1
2
Socket CN1 (OUT)
Peripheral Devices
173
Connector (Plug) with Terminating Resistance
DRS3-1
Panel-mounting Connector (5 Pins for Communications)
XS4M-D521-1
Wiring
Terminal No.
Name
1
DRAIN : NC
2
V+
: NC
3
V-
: NC
4
CAN H :
121 Ω
CAN L :
5
Note: Terminating resistance (121 Ω) is
connected between terminals 4
and 5.
30
M25 × 2
1
5
4
1
1.5 dia.
5
2
3
26 dia.
4
11
21
2
3
16
62.5
Panel Cutout Dimensions
25 dia. 2
+0.1
0
4 8.5 4.5
PCB Processing Dimensions
5, 1.8 dia.
9.1 dia.
4.8
37 min.
Note: A rubber seal and nut for panel mounting are included.
174
Peripheral Devices
I/O Peripheral Devices
Applicable Connectors
● Assembly Connector Plugs for M12 Microconnectors
Appearance
Applicable cable
diameter (mm)
Connection method
Number of
poles
Cable direction
Crimping
Soldering
Screws
XS2G-D4C1
XS2G-D421
XS2G-D4S1
L-shaped
--
XS2G-D422
XS2G-D4S2
Straight
XS2G-D4C3
XS2G-D423
XS2G-D4S3
L-shaped
--
XS2G-D424
XS2G-D4S4
Straight
XS2G-D4C5
XS2G-D425
XS2G-D4S5
L-shaped
--
XS2G-D426
XS2G-D4S6
Straight
--
--
Straight
For 6 dia.
(5 to 6 dia.)
For 5 dia.
(4 to 5 dia.)
For 3 dia.
(3 to 4 dia.)
4
For 7 dia.
(6 to 7 dia.)
XS2G-D4S9
For 8 dia.
(7 to 8 dia.)
XS2G-D4S7
Applicable Cables with Connectors
● Cables with Connector (Socket/Plug) on Both Ends (M12 Microconnectors for Power Supply and I/O)
Appearance
Number of
core wires
Cable direction
Cable length (m)
Standard cable
Robot (earthquake-resistant)
cable
1
XS2W-D421-C81-A
XS2W-D421-C81-R
2
XS2W-D421-D81-A
XS2W-D421-D81-R
5
XS2W-D421-G81-A
XS2W-D421-G81-R
2
XS2W-D422-D81-A
5
XS2W-D422-G81-A
2
XS2W-D423-D81-A
5
XS2W-D423-G81-A
2
XS2W-D424-D81-A
5
XS2W-D424-G81-A
Straight/Straight
L-shaped/L-shaped
4
Straight/L-shaped
L-shaped/Straight
--
● Cables with connector plug on One End (M12 Microconnectors for I/O)
Appearance
Number of
core wires
Cable direction
Cable length (m)
Standard cable
XS2H-D421-AC0-A
3
0.3
XS2H-D421-A80-A
4
Straight
XS2H-D421-CC0-A
3
1
XS2H-D421-C80-A
4
● Plugs and Sockets on Y-shaped Joints (M12 Microconnectors for I/O)
Appearance
Cable
DC models
Connector
Cable length (m)
Model
0.5
XS2R-D426-B11-F
1
XS2R-D426-C11-F
2
XS2R-D426-D11-F
3
XS2R-D426-E11-F
2
XS2R-D426-D10-F
5
XS2R-D426-G10-F
--
XS2R-D426-1
Connectors on both ends
With cable
Connector on one end
Without cable
Connectors on both ends
Note: Use is supported only for Environment-resistive Terminals (DRT2-@D16C(L)(-1)).
● Connector Cover for M12 Microconnectors
Appearance
Product
Model
Waterproof cover (socket)
XS2Z-22
Application
For covering unused I/O connectors
Peripheral Devices
175
Power Supply Peripheral Devices
Applicable Cables with Connectors
● Power Supply Connectors (7/8-16UN Miniconnectors)
Appearance
Product
Cable length L (mm)
Model
1
XS4W-D421-101-A
2
XS4W-D421-102-A
5
XS4W-D421-105-A
10
XS4W-D421-110-A
1
XS4F-D421-101-A
2
XS4F-D421-102-A
5
XS4F-D421-105-A
10
XS4F-D421-110-A
1
XS4H-D421-101-A
2
XS4H-D421-102-A
5
XS4H-D421-105-A
10
XS4H-D421-110-A
T-branch Connector
--
XS4R-D424-5
Panel mounting connector socket
Cable: 50 cm
--
XS4P-D421-1C5-A
Panel mounting connector plug
DIP terminals
--
XS4M-D421-1
-
Waterproofing Cap for Plug
--
XS4Z-11
-
Waterproofing Cap for Socket
--
XS4Z-12
L
L
L
176
Peripheral Devices
50
mm
50
mm
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2011.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.