SENSORTECHNICS OXYPROOF-M

OxyProof M Series
Pressure transmitters for oxygen applications
ENGINEERING PROPOSAL
FEATURES
· BAM safety approval for oxygen
applications8
· 0...4 to 0...600 bar
gage or sealed gage
· All welded sensor cell
· 0.5...4.5 V or 4...20 mA output
MEDIA COMPATIBILITY
Material in contact with media:
Stainless steel and Haynes 214 alloy
(all equivalent or better than 300 series SS)
Housing material:
Black plastic Valox; HR426 - PTB polyester
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
0.5...4.5 V output
Supply voltage (reverse polarity protection)
for 0.5...4.5 V ratiometric output
4.75...5.25 V,
max. 6 V
for 0.5...4.5 V regulated output
7...30 V
for 4...20 mA output
9.5...30 V
Maximum load current (0.5...4.5 V output)
Source
Sink
Temperature limits
Compensated and operating
Storage
Vibration
Mechanical shock
1
Sensor
3
Vout
V
2
GND
1.0 mA
1.0 mA
4...20 mA output
-40 to 60 °C
-40 to 125 °C
20.7 gRMS
Sensor
4
N/C
1
+Vs
3
N/C
V
2
50 g (5 ms)
100 g (11 ms)
-Vs
4
May 2007 / 639
+Vs
RL
GND
N/C
1/5
www.sensortechnics.com
OxyProof M Series
Pressure transmitters for oxygen applications
ENGINEERING PROPOSAL
PRESSURE SENSOR CHARACTERISTICS
Pressure range
Proof pressure1
Burst pressure2
0...4 bar (gage)
12 bar
40 bar
0...6 bar (gage)
18 bar
60 bar
0...10 bar (gage)
30 bar
100 bar
0...16 bar (gage)
48 bar
160 bar
0...25 bar (sealed gage)
75 bar
250 bar
0...40 bar (sealed gage)
80 bar
400 bar
0...60 bar (sealed gage)
120 bar
600 bar
0...100 bar (sealed gage)
200 bar
1000 bar
0...160 bar (sealed gage)
320 bar
1600 bar
0...250 bar (sealed gage)
500 bar
2068 bar
0...350 bar (sealed gage)
700 bar
2068 bar
0...500 bar (sealed gage)
1000 bar
2068 bar
0...600 bar (sealed gage)
1100 bar
2068 bar
ELECTROMAGNETIC CAPABILITY6,7
Test conditions
Radiated, radio frequency electromagnetic
field immunity (RFI)
EN61000-4-3:
Criterion
0.01 to 800 MHz, 200 V/m
800 to 1000 MHz, 150 V/m
80 % AMC (1 kHz)
A
Electrical fast transient / burst immunity (EFT)
EN61000-4-4:
Grade 3, ±2 kV
A
Electrostatic discharge immunity test (ESD)
EN61000-4-2:
Grade 2, ±4 kV
A
Immunity to conducted disturbances
induced by radio-frequency fields
EN61000-4-6:
Grade 3, 0.15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
Notes:
1
Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element.
2
Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks from the housing.
6
Tests are in accordance with EN 61000-6-2, April 1999.
7
CE-labelling is in accordance with 89/336/EEC.
8
BAM certification-No: BAM/ZBA/001/07. The BAM certificate refers only to the burn-out safety of the materials in oxygen service.
May 2007 / 639
2/5
www.sensortechnics.com
OxyProof M Series
Pressure transmitters for oxygen applications
ENGINEERING PROPOSAL
PERFORMANCE CHARACTERISTICS
0.5...4.5 V ratiometric output version (VS = 4.75...5.25 V, TA = 25°C)
Characteristics
Min.
Typ.
Zero pressure offset
0.5
Full scale span3
4.0
Non-linearity, hysteresis
and repeatability4
5
Total accuracy
4 bar and 6 bar devices
±0.5
all others
±0.25
Max.
V
all devices < 25 bar
±3.0
all others
±2.0
Response time
Supply current
4
Power supply rejection
90
Output impedance
Unit
%FSO
2.0
ms
8
mA
dB
25
Ω
Max.
Unit
0.5...4.5 V regulated output version (VS = 7...30 V, TA = 25°C)
Characteristics
Zero pressure offset
Total accuracy
4 bar and 6 bar devices
±0.5
all others
±0.25
all devices < 25 bar
±3.0
all others
±2.0
Response time
Supply current
5
Power supply rejection
90
Output impedance
V
4.0
Full scale span
5
Typ.
0.5
3
Non-linearity, hysteresis
and repeatability4
Min.
%FSO
2.0
ms
17
mA
dB
25
Ω
Notes:
3
Full scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
4
Non-linearity refers to the Best Straight Line fit measured for offset pressure, full-scale pressure and ½ full-scale pressure.
5
Total accuracy includes non-linearity, hysteresis, repeatability, zero offset and span error, thermal effect on zero offset and span.
May 2007 / 639
3/5
www.sensortechnics.com
OxyProof M Series
Pressure transmitters for oxygen applications
ENGINEERING PROPOSAL
PERFORMANCE CHARACTERISTICS (cont.)
4...20 mA output version (VS = 9.5...30 V, TA = 25°C)
Characteristics
Min.
Typ.
Zero pressure offset
4
Full scale span3
16
Non-linearity, hysteresis
and repeatability4
5
Total accuracy
Max.
mA
4 bar and 6 bar devices
±0.5
all others
±0.25
all devices < 25 bar
±3.0
all others
±2.0
Response time
2.0
Power supply rejection
90
Load limitation for current output version:
R max =
Unit
%FSO
ms
dB
Vs − 9.5 V
0.02 A
OUTLINE DRAWING
Electrical termination: M12 x 1 (Brad Harrison micro) (IP67)
Pressure connection: G 1/4"-19 (DIN 3852-2)
NOM 39 (1.54)
3
4
mass: approx. 60 g
27 (1-1/16) HEX
1
M12
2
22.88 (0.90)
12.3 (0.48)
NOM 11.7
(0.46)
G 1/4"
26.7 (1.05)
dimensions in mm (inches)
Front sealing O-ring (FKM 80) included in delivery.
May 2007 / 639
4/5
www.sensortechnics.com
OxyProof M Series
Pressure transmitters for oxygen applications
ENGINEERING PROPOSAL
OUTLINE DRAWING (cont.)
Electrical termination: M12 x 1 (Brad Harrison micro) (IP67)
Pressure connection: G 1/8" (BSP) (O-ring groove)
13.75 (0.54)
3
4
27 (1-1/16) HEX
1
M12
2
22.88 (0.90)
12.3 (0.48)
Ø18.0 (0.71)
26.7 (1.05)
Ø12.2 (0.48)
NOM 39 (1.54)
G1/8"(BSP)
6.35 (0.25)
O-ring groove
mass: approx. 60 g
dimensions in mm (inches)
Front sealing O-ring (FKM 80) included in delivery.
Note:
Other pressure ranges, output signals, electrical terminations and pressure
connections are available on request. Minimum order quantity may apply.
Please contact your nearest Sensortechnics sales office for further information.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
May 2007 / 639
5/5
www.sensortechnics.com