OxyProof M Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL FEATURES · BAM safety approval for oxygen applications8 · 0...4 to 0...600 bar gage or sealed gage · All welded sensor cell · 0.5...4.5 V or 4...20 mA output MEDIA COMPATIBILITY Material in contact with media: Stainless steel and Haynes 214 alloy (all equivalent or better than 300 series SS) Housing material: Black plastic Valox; HR426 - PTB polyester SPECIFICATIONS ELECTRICAL CONNECTION Maximum ratings 0.5...4.5 V output Supply voltage (reverse polarity protection) for 0.5...4.5 V ratiometric output 4.75...5.25 V, max. 6 V for 0.5...4.5 V regulated output 7...30 V for 4...20 mA output 9.5...30 V Maximum load current (0.5...4.5 V output) Source Sink Temperature limits Compensated and operating Storage Vibration Mechanical shock 1 Sensor 3 Vout V 2 GND 1.0 mA 1.0 mA 4...20 mA output -40 to 60 °C -40 to 125 °C 20.7 gRMS Sensor 4 N/C 1 +Vs 3 N/C V 2 50 g (5 ms) 100 g (11 ms) -Vs 4 May 2007 / 639 +Vs RL GND N/C 1/5 www.sensortechnics.com OxyProof M Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL PRESSURE SENSOR CHARACTERISTICS Pressure range Proof pressure1 Burst pressure2 0...4 bar (gage) 12 bar 40 bar 0...6 bar (gage) 18 bar 60 bar 0...10 bar (gage) 30 bar 100 bar 0...16 bar (gage) 48 bar 160 bar 0...25 bar (sealed gage) 75 bar 250 bar 0...40 bar (sealed gage) 80 bar 400 bar 0...60 bar (sealed gage) 120 bar 600 bar 0...100 bar (sealed gage) 200 bar 1000 bar 0...160 bar (sealed gage) 320 bar 1600 bar 0...250 bar (sealed gage) 500 bar 2068 bar 0...350 bar (sealed gage) 700 bar 2068 bar 0...500 bar (sealed gage) 1000 bar 2068 bar 0...600 bar (sealed gage) 1100 bar 2068 bar ELECTROMAGNETIC CAPABILITY6,7 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) EN61000-4-3: Criterion 0.01 to 800 MHz, 200 V/m 800 to 1000 MHz, 150 V/m 80 % AMC (1 kHz) A Electrical fast transient / burst immunity (EFT) EN61000-4-4: Grade 3, ±2 kV A Electrostatic discharge immunity test (ESD) EN61000-4-2: Grade 2, ±4 kV A Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-6: Grade 3, 0.15 to 80 MHz 10 V, 80 % AMC (1 kHz) A Notes: 1 Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element. 2 Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks from the housing. 6 Tests are in accordance with EN 61000-6-2, April 1999. 7 CE-labelling is in accordance with 89/336/EEC. 8 BAM certification-No: BAM/ZBA/001/07. The BAM certificate refers only to the burn-out safety of the materials in oxygen service. May 2007 / 639 2/5 www.sensortechnics.com OxyProof M Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL PERFORMANCE CHARACTERISTICS 0.5...4.5 V ratiometric output version (VS = 4.75...5.25 V, TA = 25°C) Characteristics Min. Typ. Zero pressure offset 0.5 Full scale span3 4.0 Non-linearity, hysteresis and repeatability4 5 Total accuracy 4 bar and 6 bar devices ±0.5 all others ±0.25 Max. V all devices < 25 bar ±3.0 all others ±2.0 Response time Supply current 4 Power supply rejection 90 Output impedance Unit %FSO 2.0 ms 8 mA dB 25 Ω Max. Unit 0.5...4.5 V regulated output version (VS = 7...30 V, TA = 25°C) Characteristics Zero pressure offset Total accuracy 4 bar and 6 bar devices ±0.5 all others ±0.25 all devices < 25 bar ±3.0 all others ±2.0 Response time Supply current 5 Power supply rejection 90 Output impedance V 4.0 Full scale span 5 Typ. 0.5 3 Non-linearity, hysteresis and repeatability4 Min. %FSO 2.0 ms 17 mA dB 25 Ω Notes: 3 Full scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. 4 Non-linearity refers to the Best Straight Line fit measured for offset pressure, full-scale pressure and ½ full-scale pressure. 5 Total accuracy includes non-linearity, hysteresis, repeatability, zero offset and span error, thermal effect on zero offset and span. May 2007 / 639 3/5 www.sensortechnics.com OxyProof M Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL PERFORMANCE CHARACTERISTICS (cont.) 4...20 mA output version (VS = 9.5...30 V, TA = 25°C) Characteristics Min. Typ. Zero pressure offset 4 Full scale span3 16 Non-linearity, hysteresis and repeatability4 5 Total accuracy Max. mA 4 bar and 6 bar devices ±0.5 all others ±0.25 all devices < 25 bar ±3.0 all others ±2.0 Response time 2.0 Power supply rejection 90 Load limitation for current output version: R max = Unit %FSO ms dB Vs − 9.5 V 0.02 A OUTLINE DRAWING Electrical termination: M12 x 1 (Brad Harrison micro) (IP67) Pressure connection: G 1/4"-19 (DIN 3852-2) NOM 39 (1.54) 3 4 mass: approx. 60 g 27 (1-1/16) HEX 1 M12 2 22.88 (0.90) 12.3 (0.48) NOM 11.7 (0.46) G 1/4" 26.7 (1.05) dimensions in mm (inches) Front sealing O-ring (FKM 80) included in delivery. May 2007 / 639 4/5 www.sensortechnics.com OxyProof M Series Pressure transmitters for oxygen applications ENGINEERING PROPOSAL OUTLINE DRAWING (cont.) Electrical termination: M12 x 1 (Brad Harrison micro) (IP67) Pressure connection: G 1/8" (BSP) (O-ring groove) 13.75 (0.54) 3 4 27 (1-1/16) HEX 1 M12 2 22.88 (0.90) 12.3 (0.48) Ø18.0 (0.71) 26.7 (1.05) Ø12.2 (0.48) NOM 39 (1.54) G1/8"(BSP) 6.35 (0.25) O-ring groove mass: approx. 60 g dimensions in mm (inches) Front sealing O-ring (FKM 80) included in delivery. Note: Other pressure ranges, output signals, electrical terminations and pressure connections are available on request. Minimum order quantity may apply. Please contact your nearest Sensortechnics sales office for further information. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. May 2007 / 639 5/5 www.sensortechnics.com