Laser Gas Analyzer Flyer - Remote sensing of gas concentrations directly in the process

© Siemens AG 2010
High-precision in-situ
Gas Analyzer SITRANS SL
Remote sensing of gas concentrations
directly in the process
SITRANS SL is the new in-situ technology pace maker for process control,
even in a harsh environment. The
gas analyzer combines proven-in-use
technology with a compact and robust
in-situ design. Powerful features of
SITRANS SL are the integrated laser
diode and the reference gas cell.
This technology allows laser locking
completely independent of process
gas concentrations. This leads to extremely stable operation, negligible
drift values and extended maintenance intervals.
Allied to state-of-the-art communication capabilities, these features make
SITRANS SL the best performing in-situ
laser gas analyzer available today.
SITRANS SL is the perfect solution for
single-point measurement applications in rough or hazardous environments.
SITRANS SL
Answers for industry.
s
© Siemens AG 2010
Mode of Operation
Benefits
Incorporating tunable diode laser-based
technology, this in-situ device enables
high-performance measurements. The
sensors (transmitter and receiver) are
mounted directly on the process, with no
need of sampling systems. Laser light is
sent from the transmitter, passing
through the process gas, arriving at the
detector on the receiver side. The measurements are carried out on-line with a
very short response time, permitting fast
and effective process control.
The operating principle allows measurements to be almost independent of interference from other gases, dust or aerosols. Other process influences, such as
pressure and temperature, are easily
eliminated due to the excellent inherent
compensation capabilities of this technique. An in-line reference cell filled with
a non-interfering reference gas provides
unique user benefit in terms of long term
stability with minimum need for maintenance and recalibration. This allows
higher availability and lower maintenance cost.
• In-situ measurements –
no gas sampling required
• In-line reference cell – stable instrument operation with outstanding
performance
• Dynamic dust load compensation
• Fast response time
• Almost no cross interference
• ATEX version for Ex zones I and II
(ATEX II 2 G Ex de IIC T6 /
II 2 D Ex tD A21 IP65 T85°C)
• FM version for Ex zones Div. 1
(FM XP/Class I/Div. 1/ABCD/T6
Ta=55°C;
FM Cl. I/Zone 1/AEx d IIC T6 Ta=55°C;
FM DIP/Cl. II, III/Div. 1/EFG/T6
Ta=55°C;
FM Cl. II/Zone 21/AEx tD 21 T85°C/
Type 4X/IP65)
• Enhanced communication integrated in the "Totally Integrated
Automation" (TIA) platform concept
• Unparalleled cost / performance ratio
for single-point measurements
• Low maintenance, easy to align and
service
Technical Specifications
Gases
O2, CO1)
Measuring range
O2: 0 … 1 Vol% up to 0 … 100 Vol%2)
CO: 0 … 100 ppmv up to 0 …1 000 ppmv2)
Detection limit4)
O2: 200 ppmv
CO: 0.6 ppmv
Repeatability4)
< 2 % of measuring range
Effective optical path length
0.3 ... 8 m
Process gas pressure/temperature
O2 version (B): 900 … 1 100 hPa/0 … 600 °C
Applications
O2 version (C): 700 … 5 000 hPa/0 … 200 °C
CO: 900 ... 1 100 hPa/0 … 700 °C or
900 … 2 000 hPa/max. 200 °C with same version
Depending on the actual plant situation
and in accordance with local regulations, typical applications for SITRANS
SL are:
Response time (min. T90)
1 ... 3 s, application dependent
Power supply
24 V DC
Electrical connections
• Process monitoring and control
(chemical industry)
• Process optimization (steel industry)
• Off-limit monitoring, i.e. minimum
or maximum concentration for explosion protection
• Combustion control (boilers, waste
to energy plants)
2 analog inputs/outputs3)
1 digital input
2 digital outputs
PROFIBUS DP V0 (optional)
Modbus (optional)
Protection
IP65
Flange type
Alternatively: DN50/PN25 or ANSI 4'' Class 150
Siemens AG
Industry Sector
Sensors and Communication
Process Analytics
76181 KARLSRUHE
GERMANY
www.siemens.com/processanalytics
1)
For information about additional gases please
contact your nearest Siemens representative
2)
Dependent on process conditions and effective
optical path length
3)
4…20 mA, isolated, specified for external temperature / pressure sensors (optional use)
Subject to change without prior notice
© Siemens AG 2010
4)
Value at standard conditions:
- process gas temperature 20 °C (68 °F)
- process gas pressure 1013 hPa
- effective optical path length 1 m (39’’)
- without influence of other process gases
- no influence by dust
For application-specific data please contact your
nearest Siemens representative
The information provided in this brochure contains descriptions
or characteristics of performance which in case of actual use do
not always apply as described or which may change as a result
of further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed
in the terms of contract. Availability and technical specifications
are subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third
parties for their own purposes could violate the rights of
the owners.