SHOULDER ZM206

SHOULDER ELECTRONICS CO., LTD.
CRYSTAL RESONATOR Data Sheet
PRODUCT 产 品:
CRYSTAL RESONATOR
MODEL NO 型 号: ZM206
PREPARED 编 制:
Fengyu
CHECKED 审 核:
York
APPROVED 批 准:
DATE
Http://www.shoulder.cn
日 期:
2007-01-25
SHOULDER ELECTRONICS CO., LTD.
1. SCOPE
This specification shall cover the characteristics of crystal unit with
P/N: ZM206
2. ELECTRICAL SPECIFICATION
ITEM
HOLDER TYPE
NOMINAL FREQUENCY
LOAD CAPACITANCE
FREQUENCY TOLERANCE (25℃±2℃)
EQUIVALENT SERIES RESISTANCE
DRIVE LEVEL
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE
AGING
INSULATION RESISTANCE
3. DIMENSION (Unit: mm)
4. MECHANICAL SPECIFICATION
SPECIFICATION
8X3.8x2.5mm
30.000-200.000KHz
12.5PF
±20PPM ±30 ±50
40KΩ max
1.0μW
-10℃~+60℃
-40℃~+85℃
±5PPM/YEAR
>500MΩ
1) Terminal Strength
* Lead pulling test
Conditions: Load
907.2 gram
Direction
To the downward
Duration of applied force
5 seconds
Results:
There should be no distortion in appearance.
* Lead bending test
Conditions: Load
Bending angle
Rate of bending
Number of bending
Results:
There should be no distortion in
453.6 gram
90°to normal position
3 seconds in each cycle
3
appearance.
2) Lead solderability test
Conditions: Dipping in solder(+230℃±5℃)for 5 seconds
Results:
More than 95% of surface being tested should be
coated uniformly with solder.
3) Vibration test
Conditions: Frequency
10 –55Hz
Amplitude
0.762mm
Sweep
1.0 minute
Duration
2 hours
Results:
Frequency and wave form of tested products must
Remain within specifications.
4) Drop test
Conditions: Method of drop
Natural drop
Dropping floor
Hard wood board
Height
30cm
Number of drops
3 times
Results:
Frequency and wave form of tested products must
remain within specifications.
5. ENVIRONMENTAL SPECIFICATION
1) Temperature test
* Temperature cycling test
Conditions: Steps of cycle
Results:
1) At -55℃,30 minutes
2) At +25℃,10 - 15 minutes
3) At +85℃,30 minutes
4) At +25℃,10 - 15 minutes
Number of cycles
3 times
Frequency and wave form of tested products must
remain within specifications.
* Low Temperature test
Conditions: Temperature
-20℃±2℃
Length of test
96 hours
Results:
There should be no stain on surface of products.
Frequency and wave form of tested products must
remain within specifications.
2) Aging test
Conditions:
Results:
Temperature
+85℃±20℃
Length of test
96 hours
Deviation of frequency must be less than ±3ppm
3) Salt spray test
Conditions: Temperature
+35℃±2℃
Length of test
48 hours
NaCI %
5%
Results: There should be no stain on surface of products.
4) Humidity test
Conditions: Temperature
+40℃±2℃
Relative humidity
90 - 95%
Length of test
96 hours
Results:
a. Insulation resistance must be 500 MΩ/100 Vac. minimum