SIPAT SP364

For DECT First IF Filters (F-11 Package)
SP364
Electrical Characteristic:
Characteristic
Nominal Center Frequency
3dB Bandwidth(from f0)
Stop Band Attenuation (from peak level)
1) at F0 -20MHz
2) at F0 -10MHz
3) at F0 ±4.00MHz
4) at F0 ±10MHz
5) at F0 +30MHz
Insertion Loss(at minimum loss point)
Group Delay Deviation(with F0 ±500kHz)
Input/Output Impedance (Nominal)
Input/Output Impedance(fig1):
Sym
F0
∆F3dB
Unit
MHz
KHz
dB
IL
∆T
dB
us
Spec
364.65
±500
50min
35min
10min
20min
50min
3.5max
0.7max
See fig1
F-11 Package(fig2):
L1=12nH
This may be changed according to PCB
Frequency Characteristic(fig3):
Type performance
-10
Magnitude(dB)
-20
-30
-40
-50
-60
-70
-80
320
330
340
350
360
370
Frequency(MHz)
380
390
400
410