DATA SHEET AV113-12, AV113-12LF: HIP3™ Variable Attenuator 2.1–2.3 GHz Features Connection Diagram Low Loss 1.4 dB typical ● Attenuation 18 dB typical ● Good VSWR <1.5:1 typical ● Small SOIC-8 package ● For IMT-2000 applications ● Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C per JEDEC J-STD-020 ● RF Out RF In Description Control Current Control Current The AV113-12 is a current controlled, variable attenuator from Skyworks series of HIP3™ components. It is designed to meet the wide dynamic range required in IMT-2000 applications. A monolithic quadrature hybrid is teamed with a silicon PIN diode pair in a plastic surface mount package, reducing size and assuring consistency from part to part. AV113-12LF is packaged in a lead (Pb)-free, fully RoHS-compliant SOIC-8 package and is electrically identical to AV113-12. NEW BUY NOW Skyworks offers lead (Pb)-free, RoHS (Restriction of Hazardous Substances)-compliant packaging. Innovation to GoTM Now available for purchase online. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200263 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 30, 2007 1 DATA SHEET • AV113-12, AV113-12LF Electrical Specifications at 25 °C Parameter Min. Frequency Typ. 2.1 Insertion loss (0 mA control current) 1.4 Attenuation @ 1.0 mA control current 16.5 VSWR all ports Max. Unit 2.3 GHz 1.6 18 dB dB 1.5 Input 3rd order intercept point 40 Group delay 0.4 0.8 dBm ns Typ. Max. Unit 5 8 2 µs µs mV Operating Characteristics at 25 °C (0, 5 V) Parameter(1) Switching characteristics(2) Rise, fall On, off Video feedthru (peak) Condition Frequency Min. 10/90% or 90/10% RF 50% CTL to 90/10% RF Maximum input power for <1 dB attenuation variation 15 1. All measurements made in a 50 Ω system, unless otherwise specified. 2. 0–4 mA square wave total control current. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 April 30, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200263 Rev. B dBm DATA SHEET • AV113-12, AV113-12LF Typical Performance Data 0 0 -5 -5 -10 -10 Loss (dB) Loss (dB) 2.5 GHz -15 -20 -25 2.1 GHz -30 0.5 mA -15 1.0 mA -20 -25 1.5 mA -30 -35 -35 1.7 GHz -40 -40 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 Current (mA) Frequency (GHz) Attenuation vs. Control Current Attenuation vs. Frequency 0 0 -5 -5 -10 -10 -15 Return Loss (dB) Return Loss (dB) 0 mA 2.5 GHz -20 2.1 GHz -25 2.5 GHz -15 -20 2.1 GHz -25 1.7 GHz -30 -30 1.7 GHz -35 2.5 -35 -40 -40 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Current (mA) Current (mA) Input Return Loss vs. Current Control Output Return Loss vs. Current Control Pin Out Recommended Board Layout VCONTROL 0.1630 680 Ω 220 pF 220 pF 22 nH 8 Control Current 7 GND 6 GND 5 4 RF In 3 GND 2 GND 1 Control Current 22 nH RF Out 0.0200 Dia. Via 4 Places 0.0555 Typ. 0.0190 Typ. Material is 10 mil FR4. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200263 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 30, 2007 3 DATA SHEET • AV113-12, AV113-12LF Absolute Maximum Ratings Characteristic RF input power SOIC-8 Value Pin 8 0.050 (1.27 mm) BSC 0.5 W CW, 4 W @ 12.5% duty cycle Control current 50 mA per diode Operating temperature -40 °C to +85 °C Storage temperature -65 °C to +150 °C Maximum reverse diode voltage -10 V Electrostatic discharge 125 V Performance is guaranteed only under the conditions listed in the specifications table and is not guaranteed under the full range(s) described by the Absolute Maximum specifications. Exceeding any of the absolute maximum/minimum specifications may result in permanent damage to the device and will void the warranty. CAUTION: Although this device is designed to be as robust as possible, ESD (Electrostatic Discharge) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions must be employed at all times. 0.244 (6.20 mm) 0.228 (5.80 mm) Pin 1 Indicator Pin 1 0.068 (1.73 mm) Max. 0.197 (5.00 mm) 0.189 (4.80 mm) 0.010 (0.25 mm) 0.004 (0.10 mm) 0.020 (0.51 mm) Max. 0.049 (1.24 mm) 0.016 (0.41 mm) 0.016 Max. (0.41 mm) x 45˚ Chamfer 0.158 (4.00 mm) 0.150 (3.80 mm) 0.010 (0.25 mm) 0.007 (0.17 mm) Recommended Solder Reflow Profiles Refer to the “Recommended Solder Reflow Profile” Application Note. Tape and Reel Information Refer to the “Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation” Application Note. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 April 30, 2007 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200263 Rev. B 8˚ Max. DATA SHEET • AV113-12, AV113-12LF Copyright © 2002, 2003, 2004, 2005, 2006, 2007, Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, “Breakthrough Simplicity” and HIP3 are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200263 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 30, 2007 5