SMSC LAN8710A-EZK

LAN8710/LAN8710i
MII/RMII 10/100 Ethernet
Transceiver with HP Auto-MDIX
and flexPWR® Technology in a
Small Footprint
PRODUCT FEATURES
Datasheet
Highlights
„
„
Single-Chip Ethernet Physical Layer Transceiver
(PHY)
Comprehensive flexPWR® Technology
—
—
—
—
„
„
Key Benefits
„
—
—
—
—
—
—
—
—
Flexible Power Management Architecture
Power savings of up to 40% compared to competition
LVCMOS Variable I/O voltage range: +1.6V to +3.6V
Integrated 1.2V regulator with disable feature
HP Auto-MDIX support
Small footprint 32 pin QFN lead-free RoHS compliant
package (5 x 5 x 0.9mm height)
„
„
„
„
„
„
„
„
„
„
„
„
„
„
„
Set-Top Boxes
Networked Printers and Servers
Test Instrumentation
LAN on Motherboard
Embedded Telecom Applications
Video Record/Playback Systems
Cable Modems/Routers
DSL Modems/Routers
Digital Video Recorders
IP and Video Phones
Wireless Access Points
Digital Televisions
Digital Media Adaptors/Servers
Gaming Consoles
POE Applications
Compliant with IEEE802.3/802.3u (Fast Ethernet)
Compliant with ISO 802-3/IEEE 802.3 (10BASE-T)
Loop-back modes
Auto-negotiation
Automatic polarity detection and correction
Link status change wake-up detection
Vendor specific register functions
Supports both MII and the reduced pin count RMII
interfaces
Power and I/Os
—
—
—
—
Various low power modes
Integrated power-on reset circuit
Two status LED outputs
Latch-Up Performance Exceeds 150mA per EIA/JESD
78, Class II
— May be used with a single 3.3V supply
Target Applications
„
High-Performance 10/100 Ethernet Transceiver
„
Packaging
— 32-pin QFN (5x5 mm) Lead-Free RoHS Compliant
package with MII and RMII
„
Environmental
— Extended Commercial Temperature Range (0°C to
+85°C)
— Industrial Temperature Range (-40°C to +85°C) version
available (LAN8710i)
SMSC LAN8710/LAN8710i
Revision 1.0 (04-15-09)
DATASHEET
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
ORDER NUMBER(S):
LAN8710A-EZK FOR 32-PIN, QFN LEAD-FREE ROHS COMPLIANT PACKAGE (0 TO +85°C TEMP)
LAN8710Ai-EZK FOR 32-PIN, QFN LEAD-FREE ROHS COMPLIANT PACKAGE (-40 TO +85°C TEMP)
LAN8710A-EZK-TR FOR 32-PIN, QFN LEAD-FREE ROHS COMPLIANT PACKAGE (0 TO +85°C TEMP)
LAN8710Ai-EZK-TR FOR 32-PIN, QFN LEAD-FREE ROHS COMPLIANT PACKAGE (-40 TO +85°C TEMP)
Reel Size is 4000
80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123
Copyright © 2009 SMSC or its subsidiaries. All rights reserved.
Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for
construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC
reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications
before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent
rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated
version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors
known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not
designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property
damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of
this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered
trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders.
SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE
OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL
DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT;
TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD
TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Revision 1.0 (04-15-09)
2
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table of Contents
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1
1.2
1.3
General Terms and Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Architectural Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3.1
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chapter 2 Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1
Package Pin-out Diagram and Signal Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 3 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1
3.2
3.3
3.4
3.5
3.6
3.7
MAC Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Management Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10/100 Line Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analog Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
16
17
17
17
18
18
Chapter 4 Architecture Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.1
4.2
4.3
4.4
4.5
4.6
4.7
Top Level Functional Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100Base-TX Transmit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.1
100M Transmit Data Across the MII/RMII Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.2
4B/5B Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.3
Scrambling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.4
NRZI and MLT3 Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.5
100M Transmit Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2.6
100M Phase Lock Loop (PLL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100Base-TX Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1
100M Receive Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2
Equalizer, Baseline Wander Correction and Clock and Data Recovery . . . . . . . . . . . . .
4.3.3
NRZI and MLT-3 Decoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.4
Descrambling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5
Alignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.6
5B/4B Decoding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.7
Receive Data Valid Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.8
Receiver Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.9
100M Receive Data Across the MII/RMII Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10Base-T Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1
10M Transmit Data Across the MII/RMII Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.2
Manchester Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.3
10M Transmit Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10Base-T Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1
10M Receive Input and Squelch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.2
Manchester Decoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3
10M Receive Data Across the MII/RMII Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.4
Jabber Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAC Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.1
MII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.2
RMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.3
MII vs. RMII Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auto-negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMSC LAN8710/LAN8710i
3
DATASHEET
19
19
19
20
21
21
21
22
22
22
22
23
23
23
23
23
24
24
24
24
25
25
25
25
25
26
26
26
26
26
27
28
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.7.1
Parallel Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.2
Re-starting Auto-negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.3
Disabling Auto-negotiation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.4
Half vs. Full Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HP Auto-MDIX Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal +1.2V Regulator Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.1
Disable the Internal +1.2V Regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.2
Enable the Internal +1.2V Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
nINTSEL Strapping and LED Polarity Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REGOFF and LED Polarity Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PHY Address Strapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Variable Voltage I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transceiver Management Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.14.1 Serial Management Interface (SMI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
30
30
30
30
31
31
31
32
32
33
33
33
33
Chapter 5 SMI Register Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.1
5.2
5.3
SMI Register Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.1
Primary Interrupt System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.2
Alternate Interrupt System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.1
Carrier Sense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.2
Collision Detect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.3
Isolate Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.4
Link Integrity Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.5
Power-Down modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.6
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.7
LED Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.8
Loopback Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.9
Configuration Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
47
47
48
48
48
49
49
49
49
50
50
50
52
Chapter 6 AC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
6.1
6.2
6.3
6.4
6.5
6.6
Serial Management Interface (SMI) Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MII 10/100Base-TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.1
MII 100Base-T TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.2
MII 10Base-T TX/RX Timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RMII 10/100Base-TX/RX Timings (50MHz REF_CLK IN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.1
RMII 100Base-T TX/RX Timings (50MHz REF_CLK IN). . . . . . . . . . . . . . . . . . . . . . . . .
6.3.2
RMII 10Base-T TX/RX Timings (50MHz REF_CLK IN). . . . . . . . . . . . . . . . . . . . . . . . . .
RMII CLKIN Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clock Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
55
56
56
58
60
60
62
64
64
65
Chapter 7 DC Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
7.1
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1.1
Maximum Guaranteed Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1.2
Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1.3
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1.4
DC Characteristics - Input and Output Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
66
66
67
68
69
Chapter 8 Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8.1
Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8.1.1
MII Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8.1.2
Power Supply Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Revision 1.0 (04-15-09)
4
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
8.2
8.1.3
Twisted-Pair Interface Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Magnetics Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Chapter 9 Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
SMSC LAN8710/LAN8710i
5
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
List of Figures
Figure 1.1
Figure 1.2
Figure 2.1
Figure 4.1
Figure 4.2
Figure 4.3
Figure 4.4
Figure 4.5
Figure 4.6
Figure 4.7
Figure 4.8
Figure 5.1
Figure 5.2
Figure 5.3
Figure 6.1
Figure 6.2
Figure 6.3
Figure 6.4
Figure 6.5
Figure 6.6
Figure 6.7
Figure 6.8
Figure 6.9
Figure 6.10
Figure 8.1
Figure 8.2
Figure 8.3
Figure 8.4
Figure 8.5
Figure 9.1
Figure 9.1
Figure 9.2
Figure 9.3
LAN8710/LAN8710i System Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAN8710/LAN8710i Architectural Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAN8710/LAN8710i 32-QFN Pin Assignments (TOP VIEW). . . . . . . . . . . . . . . . . . . . . . . . .
100Base-TX Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receive Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relationship Between Received Data and Specific MII Signals . . . . . . . . . . . . . . . . . . . . . .
Direct Cable Connection vs. Cross-over Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . .
nINTSEL Strapping on LED2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REGOFF Configuration on LED1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MDIO Timing and Frame Structure - READ Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MDIO Timing and Frame Structure - WRITE Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Near-end Loopback Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Far Loopback Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connector Loopback Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMI Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100M MII Receive Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100M MII Transmit Timing Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10M MII Receive Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10M MII Transmit Timing Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100M RMII Receive Timing Diagram (50MHz REF_CLK IN). . . . . . . . . . . . . . . . . . . . . . . . .
100M RMII Transmit Timing Diagram (50MHz REF_CLK IN) . . . . . . . . . . . . . . . . . . . . . . . .
10M RMII Receive Timing Diagram (50MHz REF_CLK IN). . . . . . . . . . . . . . . . . . . . . . . . . .
10M RMII Transmit Timing Diagram (50MHz REF_CLK IN) . . . . . . . . . . . . . . . . . . . . . . . . .
Reset Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simplified Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High-Level System Diagram for Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High-Level System Diagram for Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copper Interface Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copper Interface Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAN8710/LAN8710i-EZK 32 Pin QFN Package Outline, 5 x 5 x 0.9 mm Body (Lead-Free) .
QFN, 5x5 Taping Dimensions and Part Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reel Dimensions for 12mm Carrier Tape. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tape Length and Part Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision 1.0 (04-15-09)
6
DATASHEET
10
11
12
19
22
24
31
32
33
34
34
51
51
52
55
56
57
58
59
60
61
62
63
64
73
74
74
74
74
76
77
78
79
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
List of Tables
Table 2.1 LAN8710/LAN8710i 32-PIN QFN Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.1 Buffer Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.2 MII/RMII Signals 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.3 LED Signals 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.4 Management Signals 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.5 General Signals 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.6 10/100 Line Interface Signals 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.7 Analog References 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3.8 Power Signals 32-QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4.1 4B/5B Code Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4.2 MII/RMII Signal Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4.3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.1 Control Register: Register 0 (Basic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.2 Status Register: Register 1 (Basic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.3 PHY ID 1 Register: Register 2 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.4 PHY ID 2 Register: Register 3 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.5 Auto-Negotiation Advertisement: Register 4 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.6 Auto-Negotiation Link Partner Base Page Ability Register: Register 5 (Extended) . . . . . . . . .
Table 5.7 Auto-Negotiation Expansion Register: Register 6 (Extended). . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.8 Register 15 (Extended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.9 Silicon Revision Register 16: Vendor-Specific. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.10 Mode Control/ Status Register 17: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.11 Special Modes Register 18: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.12 Register 24: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.13 Register 25: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.14 Symbol Error Counter Register 26: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.15 Special Control/Status Indications Register 27: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . .
Table 5.16 Special Internal Testability Control Register 28: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . .
Table 5.17 Interrupt Source Flags Register 29: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.18 Interrupt Mask Register 30: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.19 PHY Special Control/Status Register 31: Vendor-Specific . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.20 SMI Register Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.21 Register 0 - Basic Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.22 Register 1 - Basic Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.23 Register 2 - PHY Identifier 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.24 Register 3 - PHY Identifier 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.25 Register 4 - Auto Negotiation Advertisement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.26 Register 5 - Auto Negotiation Link Partner Ability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.27 Register 6 - Auto Negotiation Expansion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.28 Register 16 - Silicon Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.29 Register 17 - Mode Control/Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.30 Register 18 - Special Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.31 Register 26 - Symbol Error Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.33 Register 28 - Special Internal Testability Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.34 Register 29 - Interrupt Source Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.32 Register 27 - Special Control/Status Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.35 Register 30 - Interrupt Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.36 Register 31 - PHY Special Control/Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.37 Interrupt Management Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.38 Alternative Interrupt System Management Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.39 Pin Names for Address Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.40 MODE[2:0] Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 5.41 Pin Names for Mode Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMSC LAN8710/LAN8710i
7
DATASHEET
13
14
14
16
17
17
17
18
18
20
28
32
35
35
35
35
36
36
36
36
36
37
37
37
37
37
38
38
38
38
38
39
40
40
41
41
41
42
43
43
43
44
44
45
45
45
46
46
47
48
52
53
53
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 6.1 SMI Timing Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.2 100M MII Receive Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.3 100M MII Transmit Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.4 10M MII Receive Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.5 10M MII Transmit Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.6 100M RMII Receive Timing Values (50MHz REF_CLK IN). . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.7 100M RMII Transmit Timing Values (50MHz REF_CLK IN) . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.8 10M RMII Receive Timing Values (50MHz REF_CLK IN). . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.9 10M RMII Transmit Timing Values (50MHz REF_CLK IN) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.10 RMII CLKIN (REF_CLK) Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.11 Reset Timing Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6.12 LAN8710/LAN8710i Crystal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.1 Maximum Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.2 ESD and LATCH-UP Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.3 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.4 Power Consumption Device Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.5 MII Bus Interface Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.6 LAN Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.7 LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.8 Configuration Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.9 General Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.10 Internal Pull-Up / Pull-Down Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.11 100Base-TX Transceiver Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7.12 10BASE-T Transceiver Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 9.1 32 Terminal QFN Package Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision 1.0 (04-15-09)
8
DATASHEET
55
56
57
58
59
60
61
62
63
64
64
65
66
66
67
68
69
70
70
70
70
71
71
72
76
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 1 Introduction
1.1
General Terms and Conventions
The following is list of the general terms used in this document:
BYTE
8-bits
FIFO
First In First Out buffer; often used for elasticity buffer
MAC
Media Access Controller
MII
Media Independent Interface
RMIITM
Reduced Media Independent InterfaceTM
N/A
Not Applicable
X
Indicates that a logic state is “don’t care” or undefined.
RESERVED
Refers to a reserved bit field or address. Unless otherwise noted, reserved
bits must always be zero for write operations. Unless otherwise noted, values
are not guaranteed when reading reserved bits. Unless otherwise noted, do
not read or write to reserved addresses.
SMI
Serial Management Interface
1.2
General Description
The LAN8710/LAN8710i is a low-power 10BASE-T/100BASE-TX physical layer (PHY) transceiver that
transmits and receives on unshielded twisted-pair cable. A typical system application is shown in
Figure 1.2. It is available in both extended commercial and industrial temperature operating versions.
The LAN8710/LAN8710i interfaces to the MAC layer using a variable voltage digital interface via the
standard MII (IEEE 802.3u). Support for RMII makes a reduced pin-count interface available. The
digital interface pins are tolerant to 3.6V.
The LAN8710/LAN8710i implements Auto-Negotiation to automatically determine the best possible
speed and duplex mode of operation. HP Auto-MDIX support allows using a direct connect LAN cable,
or a cross-over path cable.
The LAN8710 referenced throughout this document applies to both the extended commercial
temperature and industrial temperature components. The LAN8710i refers to only the industrial
temperature component.
SMSC LAN8710/LAN8710i
9
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
10/100
Ethernet
MAC
MDI
Transformer
RJ45
LAN8710
MII or
RMII
Ethernet
Transceiver
MODE
LED Status
Crystal or
Clock Osc
Figure 1.1 LAN8710/LAN8710i System Block Diagram
1.3
Architectural Overview
The LAN8710/LAN8710i is compliant with IEEE 802.3-2005 standards (MII Pins tolerant to 3.6V) and
supports both IEEE 802.3-2005 compliant and vendor-specific register functions. It contains a fullduplex 10-BASE-T/100BASE-TX transceiver and supports 10-Mbps (10BASE-T) operation, and 100Mbps (100BASE-TX) operation. The LAN8710/LAN8710i can be configured to operate on a single 3.3V
supply utilizing an integrated 3.3V to 1.2V linear regulator. An option is available to disable the linear
regulator to optimize system designs that have a 1.2V power supply available. This allows for the use
of a high efficiency external regulator for lower system power dissipation.
1.3.1
Configuration
The LAN8710 will begin normal operation following reset, and no register access is required. The initial
configuration may be selected with configuration pins as described in Section 5.3.9. In addition,
register-selectable configuration options may be used to further define the functionality of the
transceiver. For example, the device can be set to 10BASE-T only. The LAN8710 supports both IEEE
802.3-2005 compliant and vendor-specific register functions.
Revision 1.0 (04-15-09)
10
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
MODE0
MODE1
MODE2
nRST
MODE Control
AutoNegotiation
10M Tx
Logic
Reset
Control
SMI
RMIISEL
10M
Transmitter
HP Auto-MDIX
TXP / TXN
Transmit Section
100M Tx
Logic
Management
Control
RXP / RXN
100M
Transmitter
MDIX
Control
TXD[0:3]
TXEN
TXER
TXCLK
CRS
COL/CRS_DV
RMII / MII Logic
RXD[0:3]
RXDV
RXER
RXCLK
100M Rx
Logic
MDC
MDIO
DSP System:
Clock
Data Recovery
Equalizer
Analog-toDigital
XTAL1/CLKIN
PLL
XTAL2
Interrupt
Generator
nINT
100M PLL
Receive Section
LED Circuitry
10M Rx
Logic
Squelch &
Filters
10M PLL
LED1
LED2
Central
Bias
RBIAS
PHY
Address
Latches
PHYAD[0:2]
Figure 1.2 LAN8710/LAN8710i Architectural Overview
SMSC LAN8710/LAN8710i
11
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 2 Pin Configuration
RBIAS
RXP
RXN
TXP
TXN
VDD1A
RXDV
TXD3
32
31
30
29
28
27
26
25
Package Pin-out Diagram and Signal Table
VDD2A
1
24
TXD2
LED2/nINTSEL
2
23
TXD1
LED1/REGOFF
3
22
TXD0
21
TXEN
20
TXCLK
19
nRST
18
nINT/TXER/TXD4
17
MDC
14
15
16
CRS
MDIO
RXD2/RMIISEL
COL/CRS_DV/MODE2
VSS
13
8
RXER/RXD4/PHYAD0
RXD3/PHYAD2
12
7
11
6
VDDIO
VDDCR
RXCLK/PHYAD1
RXD0/MDE0
5
10
4
RXD1/MODE1
XTAL2
XTAL1/CLKIN
SMSC
LAN8710/LAN8710i
32 PIN QFN
(Top View)
9
2.1
Figure 2.1 LAN8710/LAN8710i 32-QFN Pin Assignments (TOP VIEW)
Revision 1.0 (04-15-09)
12
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 2.1 LAN8710/LAN8710i 32-PIN QFN Pinout
PIN NO.
PIN NAME
PIN NO.
PIN NAME
1
VDD2A
17
MDC
2
LED2/nINTSEL
18
nINT/TXER/TXD4
3
LED1/REGOFF
19
nRST
4
XTAL2
20
TXCLK
5
XTAL1/CLKIN
21
TXEN
6
VDDCR
22
TXD0
7
RXCLK//PHYAD1
23
TXD1
8
RXD3/PHYAD2
24
TXD2
9
RXD2/RMIISEL
25
TXD3
10
RXD1/MODE1
26
RXDV
11
RXD0/MODE0
27
VDD1A
12
VDDIO
28
TXN
13
RXER/RXD4/PHYAD0
29
TXP
14
CRS
30
RXN
15
COL/CRS_DV/MODE2
31
RXP
16
MDIO
32
RBIAS
SMSC LAN8710/LAN8710i
13
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 3 Pin Description
This chapter describes the signals on each pin. When a lower case “n” is used at the beginning of the
signal name, it indicates that the signal is active low. For example, nRST indicates that the reset signal
is active low. The buffer type for each signal is indicated in the TYPE column, and a description of the
buffer types is provided in Table 3.1.
Table 3.1 Buffer Types
BUFFER TYPE
DESCRIPTION
I8
Input.
O8
Output with 8mA sink and 8mA source.
IOD8
Input/Open-drain output with 8mA sink.
IPU
Note 3.1
Input with 67k (typical) internal pull-up.
IPD
Note 3.1
Input with 67k (typical) internal pull-down.
IOPU
Note 3.1
Input/Output with 67k (typical) internal pull-up. Output has 8mA sink and 8mA source.
IOPD
Note 3.1
Input/Output with 67k (typical) internal pull-down. Output has 8mA sink and 8mA source.
AI
Analog input
AIO
Analog bi-directional
ICLK
Crystal oscillator input pin
OCLK
Crystal oscillator output pin
P
Power pin
Note 3.1
Unless otherwise noted in the pin description, internal pull-up and pull-down resistors are
always enabled. The internal pull-up and pull-down resistors prevent unconnected inputs
from floating, and must not be relied upon to drive signals external to LAN8710/LAN8710i.
When connected to a load that must be pulled high or low, an external resistor must be
added.
Note: The digital signals are not 5V tolerant.They are variable voltage from +1.6V to +3.6V, as shown
in Table 7.1.
3.1
MAC Interface Signals
Table 3.2 MII/RMII Signals 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
TXD0
22
I8
Transmit Data 0: The MAC transmits data to the transceiver using this
signal in all modes.
TXD1
23
I8
Transmit Data 1: The MAC transmits data to the transceiver using this
signal in all modes
Revision 1.0 (04-15-09)
DESCRIPTION
14
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 3.2 MII/RMII Signals (continued) 32-QFN (continued)
SIGNAL
NAME
32-QFN
PIN #
TYPE
TXD2
24
I8
Transmit Data 2: The MAC transmits data to the transceiver using this
signal in MII Mode.
„ This signal should be grounded in RMII Mode.
TXD3
25
I8
Transmit Data 3: The MAC transmits data to the transceiver using this
signal in MII Mode.
„ This signal should be grounded in RMII Mode.
nINT/
TXER/
TXD4
18
IOPU
DESCRIPTION
nINT – Active low interrupt output. Place an external resistor pull-up to
VDDIO.
„ See Section 4.10 for information on how nINTSEL is used to determine
the function for this pin.
TXER – MII Transmit Error: When driven high, the 4B/5B encode process
substitutes the Transmit Error code-group (/H/) for the encoded data word.
This input is ignored in 10Base-T operation.
TXD4 – MII Transmit Data 4: In Symbol Interface (5B Decoding) mode, this
signal becomes the MII Transmit Data 4 line, the MSB of the 5-bit symbol
code-group.
„ TXD4 is not used in RMII Mode.
„ This signal is mux’d with nINT
TXEN
21
IPD
Transmit Enable: Indicates that valid data is presented on the TXD[3:0]
signals, for transmission. In RMII Mode, only TXD[1:0] have valid data.
TXCLK
20
O8
Transmit Clock: Used to latch data from the MAC into the transceiver.
„ MII (100BT): 25MHz
„ MII (10BT): 2.5MHz
„ This signal is not used in RMII Mode.
RXD0/
MODE0
11
IOPU
RXD0 – Receive Data 0: Bit 0 of the 4 data bits that are sent by the
transceiver in the receive path.
MODE0 – PHY Operating Mode Bit 0: set the default MODE of the PHY.
„ See Section 5.3.9.2 for information on the MODE options.
RXD1/
MODE1
10
IOPU
RXD1 – Receive Data 1: Bit 1 of the 4 data bits that are sent by the PHY
in the receive path.
MODE1 – PHY Operating Mode Bit 1: set the default MODE of the PHY.
See Section 5.3.9.2 for information on the MODE options.
„
RXD2/
RMIISEL
9
IOPD
RXD2 – Receive Data 2: Bit 2 of the 4 data bits that are sent by the
transceiver in the receive path.
„ The RXD2 signal is not used in RMII Mode.
RMIISEL – MII/RMII Mode Selection: Latched on the rising edge of the
internal reset (nRESET) based on the following strapping:
„ By default, MII mode is selected.
„ Pull this pin high to VDDIO with an external resistor to select RMII mode,
RXD3/
PHYAD2
8
IOPD
RXD3 – Receive Data 3: Bit 3 of the 4 data bits that are sent by the
transceiver in the receive path.
„ This signal is not used in RMII Mode.
„ This signal is mux’d with PHYAD2
PHYAD2 – PHY Address Bit 2: set the SMI address of the transceiver.
„ See Section 5.3.9.1 for information on the ADDRESS options.
SMSC LAN8710/LAN8710i
15
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 3.2 MII/RMII Signals (continued) 32-QFN (continued)
SIGNAL
NAME
32-QFN
PIN #
TYPE
DESCRIPTION
RXER/
RXD4/
PHYAD0
13
IOPD
RXER – Receive Error: Asserted to indicate that an error was detected
somewhere in the frame presently being transferred from the transceiver.
„ The RXER signal is optional in RMII Mode.
RXD4 – MII Receive Data 4: In Symbol Interface (5B Decoding) mode, this
signal is the MII Receive Data 4 signal, the MSB of the received 5-bit
symbol code-group. Unless configured in this mode, the pin functions as
RXER.
„ This signal is mux’d with PHYAD0
PHYAD0 – PHY Address Bit 0: set the SMI address of the PHY.
„ See Section 5.3.9.1 for information on the ADDRESS options.
RXCLK/
PHYAD1
7
IOPD
RXCLK – Receive Clock: In MII mode, this pin is the receive clock output.
25MHz in 100Base-TX mode. 2.5MHz in 10Base-T mode.
„ This signal is mux’d with PHYAD1
PHYAD1 – PHY Address Bit 1: set the SMI address of the transceiver.
„ See Section 5.3.9.1 for information on the ADDRESS options.
RXDV
26
O8
Receive Data Valid: Indicates that recovered and decoded data is being
presented on RXD pins.
COL/
CRS_DV/
MODE2
15
IOPU
COL – MII Mode Collision Detect: Asserted to indicate detection of
collision condition.
CRS_DV – RMII Mode CRS_DV (Carrier Sense/Receive Data Valid)
Asserted to indicate when the receive medium is non-idle. When a 10BT
packet is received, CRS_DV is asserted, but RXD[1:0] is held low until the
SFD byte (10101011) is received. In 10BT, half-duplex mode, transmitted
data is not looped back onto the receive data pins, per the RMII standard.
MODE2 – PHY Operating Mode Bit 2: set the default MODE of the PHY.
See Section 5.3.9.2 for information on the MODE options.
„
CRS
3.2
14
IOPD
Carrier Sense: Indicates detection of carrier.
LED Signals
Table 3.3 LED Signals 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
LED1/
REGOFF
3
IOPD
DESCRIPTION
LED1 – Link activity LED Indication.
See Section 5.3.7 for a description of LED modes.
REGOFF – Regulator Off: This pin may be used to configure the internal
1.2V regulator off. As described in Section 4.9, this pin is sampled during the
power-on sequence to determine if the internal regulator should turn on.
When the regulator is disabled, external 1.2V must be supplied to VDDCR.
„ When LED1/REGOFF is pulled high to VDD2A with an external resistor, the
internal regulator is disabled.
„ When LED1/REGOFF is floating or pulled low, the internal regulator is
enabled (default).
Revision 1.0 (04-15-09)
16
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 3.3 LED Signals 32-QFN (continued)
SIGNAL
NAME
32-QFN
PIN #
TYPE
LED2/
nINTSEL
2
IOPU
DESCRIPTION
LED2 – Link Speed LED Indication.
See Section 5.3.7 for a description of LED modes.
nINTSEL: On power-up or external reset, the mode of the nINT/TXER/TXD4
pin is selected.
„ When LED2/nINTSEL is floated or pulled to VDDIO, nINT is selected for
operation on pin nINT/TXER/TXD4 (default).
„ When LED2/nINTSEL is pulled low to VSS through a resistor, TXER/TXD4
is selected for operation on pin nINT/TXER/TXD4.
„ See Section 4.10 for additional information.
3.3
Management Signals
Table 3.4 Management Signals 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
MDIO
16
IOD8
MDC
17
I8
3.4
DESCRIPTION
Management Data Input/OUTPUT: Serial management data input/output.
Management Clock: Serial management clock.
General Signals
Table 3.5 General Signals 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
XTAL1/
CLKIN
5
ICLK
Clock Input: Crystal connection or external clock input.
XTAL2
4
OCLK
Clock Output: Crystal connection.
Float this pin when an external clock is driven to XTAL1/CLKIN.
nRST
19
IOPU
External Reset: Input of the system reset. This signal is active LOW.
3.5
DESCRIPTION
10/100 Line Interface Signals
Table 3.6 10/100 Line Interface Signals 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
TXP
29
AIO
SMSC LAN8710/LAN8710i
DESCRIPTION
Transmit/Receive Positive Channel 1.
17
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 3.6 10/100 Line Interface Signals (continued) 32-QFN (continued)
SIGNAL
NAME
32-QFN
PIN #
TYPE
TXN
28
AIO
Transmit/Receive Negative Channel 1.
RXP
31
AIO
Transmit/Receive Positive Channel 2.
RXN
30
AIO
Transmit/Receive Negative Channel 2.
3.6
DESCRIPTION
Analog Reference
Table 3.7 Analog References 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
DESCRIPTION
RBIAS
32
AI
External 1% Bias Resistor. Requires a 12.1k ohm (1%) resistor to ground
connected as described in the Analog Layout Guidelines. The nominal
voltage is 1.2V and the resistor will dissipate approximately 1mW of power.
3.7
Power Signals
Table 3.8 Power Signals 32-QFN
SIGNAL
NAME
32-QFN
PIN #
TYPE
VDDIO
12
P
+1.6V to +3.6V Variable I/O Pad Power
VDDCR
6
P
+1.2V (Core voltage) - 1.2V for digital circuitry on chip. Supplied by the onchip regulator unless configured for regulator off mode using the
LED1/REGOFF pin. A 1uF decoupling capacitor to ground should be used on
this pin when using the internal 1.2V regulator.
VDD1A
27
P
+3.3V Analog Port Power to Channel 1.
VDD2A
1
P
+3.3V Analog Port Power to Channel 2 and to internal regulator.
VSS
FLAG
GND
Revision 1.0 (04-15-09)
DESCRIPTION
The flag must be connected to the ground plane with a via array under the
exposed flag. This is the ground connection for the IC.
18
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 4 Architecture Details
4.1
Top Level Functional Architecture
Functionally, the transceiver can be divided into the following sections:
„
100Base-TX transmit and receive
„
10Base-T transmit and receive
„
MII or RMII interface to the controller
„
Auto-negotiation to automatically determine the best speed and duplex possible
„
Management Control to read status registers and write control registers
TX _C LK
(for M II only)
MAC
P LL
E xt R ef_C LK (for R M II only)
M II 25 M hz by 4 bits
or
R M II 50M hz by 2 bits
125 M bps S erial
M II/R M II
25M H z
by 4 bits
4B /5B
E ncoder
N R ZI
C onverter
N R ZI
M LT -3
C onverter
M LT -3
M LT-3
M agnetics
M LT -3
25M H z by
5 bits
R J45
S cram bler
and P IS O
Tx
D river
M LT-3
C A T-5
Figure 4.1 100Base-TX Data Path
4.2
100Base-TX Transmit
The data path of the 100Base-TX is shown in Figure 4.1. Each major block is explained below.
4.2.1
100M Transmit Data Across the MII/RMII Interface
For MII, the MAC controller drives the transmit data onto the TXD bus and asserts TXEN to indicate
valid data. The data is latched by the transceiver’s MII block on the rising edge of TXCLK. The data
is in the form of 4-bit wide 25MHz data.
For RMII, the MAC controller drives the transmit data onto the TXD bus and asserts TXEN to indicate
valid data. The data is latched by the transceiver’s RMII block on the rising edge of REF_CLK. The
data is in the form of 2-bit wide 50MHz data.
SMSC LAN8710/LAN8710i
19
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
4.2.2
4B/5B Encoding
The transmit data passes from the MII block to the 4B/5B encoder. This block encodes the data from
4-bit nibbles to 5-bit symbols (known as “code-groups”) according to Table 4.1. Each 4-bit data-nibble
is mapped to 16 of the 32 possible code-groups. The remaining 16 code-groups are either used for
control information or are not valid.
The first 16 code-groups are referred to by the hexadecimal values of their corresponding data nibbles,
0 through F. The remaining code-groups are given letter designations with slashes on either side. For
example, an IDLE code-group is /I/, a transmit error code-group is /H/, etc.
The encoding process may be bypassed by clearing bit 6 of register 31. When the encoding is
bypassed the 5th transmit data bit is equivalent to TXER.
Note that encoding can be bypassed only when the MAC interface is configured to operate in MII
mode.
Table 4.1 4B/5B Code Table
CODE
GROUP
SYM
RECEIVER
INTERPRETATION
11110
0
0
0000
01001
1
1
10100
2
10101
TRANSMITTER
INTERPRETATION
0
0000
0001
1
0001
2
0010
2
0010
3
3
0011
3
0011
01010
4
4
0100
4
0100
01011
5
5
0101
5
0101
01110
6
6
0110
6
0110
01111
7
7
0111
7
0111
10010
8
8
1000
8
1000
10011
9
9
1001
9
1001
10110
A
A
1010
A
1010
10111
B
B
1011
B
1011
11010
C
C
1100
C
1100
11011
D
D
1101
D
1101
11100
E
E
1110
E
1110
11101
F
F
1111
F
1111
11111
I
IDLE
Sent after /T/R until TXEN
11000
J
First nibble of SSD, translated to “0101”
following IDLE, else RXER
Sent for rising TXEN
10001
K
Second nibble of SSD, translated to
“0101” following J, else RXER
Sent for rising TXEN
01101
T
First nibble of ESD, causes de-assertion
of CRS if followed by /R/, else assertion
of RXER
Sent for falling TXEN
Revision 1.0 (04-15-09)
DATA
20
DATASHEET
DATA
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 4.1 4B/5B Code Table (continued)
CODE
GROUP
SYM
00111
R
Second nibble of ESD, causes
deassertion of CRS if following /T/, else
assertion of RXER
Sent for falling TXEN
00100
H
Transmit Error Symbol
Sent for rising TXER
00110
V
INVALID, RXER if during RXDV
INVALID
11001
V
INVALID, RXER if during RXDV
INVALID
00000
V
INVALID, RXER if during RXDV
INVALID
00001
V
INVALID, RXER if during RXDV
INVALID
00010
V
INVALID, RXER if during RXDV
INVALID
00011
V
INVALID, RXER if during RXDV
INVALID
00101
V
INVALID, RXER if during RXDV
INVALID
01000
V
INVALID, RXER if during RXDV
INVALID
01100
V
INVALID, RXER if during RXDV
INVALID
10000
V
INVALID, RXER if during RXDV
INVALID
4.2.3
RECEIVER
INTERPRETATION
TRANSMITTER
INTERPRETATION
Scrambling
Repeated data patterns (especially the IDLE code-group) can have power spectral densities with large
narrow-band peaks. Scrambling the data helps eliminate these peaks and spread the signal power
more uniformly over the entire channel bandwidth. This uniform spectral density is required by FCC
regulations to prevent excessive EMI from being radiated by the physical wiring.
The seed for the scrambler is generated from the transceiver address, PHYAD[4:0], ensuring that in
multiple-transceiver applications, such as repeaters or switches, each transceiver will have its own
scrambler sequence.
The scrambler also performs the Parallel In Serial Out conversion (PISO) of the data.
4.2.4
NRZI and MLT3 Encoding
The scrambler block passes the 5-bit wide parallel data to the NRZI converter where it becomes a
serial 125MHz NRZI data stream. The NRZI is encoded to MLT-3. MLT3 is a tri-level code where a
change in the logic level represents a code bit “1” and the logic output remaining at the same level
represents a code bit “0”.
4.2.5
100M Transmit Driver
The MLT3 data is then passed to the analog transmitter, which drives the differential MLT-3 signal, on
outputs TXP and TXN, to the twisted pair media across a 1:1 ratio isolation transformer. The 10BaseT and 100Base-TX signals pass through the same transformer so that common “magnetics” can be
used for both. The transmitter drives into the 100Ω impedance of the CAT-5 cable. Cable termination
and impedance matching require external components.
SMSC LAN8710/LAN8710i
21
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
4.2.6
100M Phase Lock Loop (PLL)
„
The 100M PLL locks onto reference clock and generates the 125MHz clock used to drive the 125
MHz logic and the 100Base-Tx Transmitter.
TX _C LK
(for M II only)
MAC
P LL
E xt R ef_C LK (for R M II only)
M II 25 M hz by 4 bits
or
R M II 50M hz by 2 bits
125 M bps S erial
M II/R M II
25M H z
by 4 bits
4B /5B
E ncoder
N R ZI
C onverter
N R ZI
M LT -3
C onverter
M LT -3
M LT-3
M agnetics
M LT -3
R J45
25M H z by
5 bits
S cram bler
and P IS O
Tx
D river
M LT-3
C A T-5
Figure 4.2 Receive Data Path
4.3
100Base-TX Receive
The receive data path is shown in Figure 4.2. Detailed descriptions are given below.
4.3.1
100M Receive Input
The MLT-3 from the cable is fed into the transceiver (on inputs RXP and RXN) via a 1:1 ratio
transformer. The ADC samples the incoming differential signal at a rate of 125M samples per second.
Using a 64-level quanitizer it generates 6 digital bits to represent each sample. The DSP adjusts the
gain of the ADC according to the observed signal levels such that the full dynamic range of the ADC
can be used.
4.3.2
Equalizer, Baseline Wander Correction and Clock and Data Recovery
The 6 bits from the ADC are fed into the DSP block. The equalizer in the DSP section compensates
for phase and amplitude distortion caused by the physical channel consisting of magnetics, connectors,
and CAT- 5 cable. The equalizer can restore the signal for any good-quality CAT-5 cable between 1m
and 150m.
If the DC content of the signal is such that the low-frequency components fall below the low frequency
pole of the isolation transformer, then the droop characteristics of the transformer will become
significant and Baseline Wander (BLW) on the received signal will result. To prevent corruption of the
received data, the transceiver corrects for BLW and can receive the ANSI X3.263-1995 FDDI TP-PMD
defined “killer packet” with no bit errors.
The 100M PLL generates multiple phases of the 125MHz clock. A multiplexer, controlled by the timing
unit of the DSP, selects the optimum phase for sampling the data. This is used as the received
recovered clock. This clock is used to extract the serial data from the received signal.
Revision 1.0 (04-15-09)
22
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
4.3.3
NRZI and MLT-3 Decoding
The DSP generates the MLT-3 recovered levels that are fed to the MLT-3 converter. The MLT-3 is then
converted to an NRZI data stream.
4.3.4
Descrambling
The descrambler performs an inverse function to the scrambler in the transmitter and also performs
the Serial In Parallel Out (SIPO) conversion of the data.
During reception of IDLE (/I/) symbols. the descrambler synchronizes its descrambler key to the
incoming stream. Once synchronization is achieved, the descrambler locks on this key and is able to
descramble incoming data.
Special logic in the descrambler ensures synchronization with the remote transceiver by searching for
IDLE symbols within a window of 4000 bytes (40us). This window ensures that a maximum packet size
of 1514 bytes, allowed by the IEEE 802.3 standard, can be received with no interference. If no IDLEsymbols are detected within this time-period, receive operation is aborted and the descrambler re-starts
the synchronization process.
The descrambler can be bypassed by setting bit 0 of register 31.
4.3.5
Alignment
The de-scrambled signal is then aligned into 5-bit code-groups by recognizing the /J/K/ Start-of-Stream
Delimiter (SSD) pair at the start of a packet. Once the code-word alignment is determined, it is stored
and utilized until the next start of frame.
4.3.6
5B/4B Decoding
The 5-bit code-groups are translated into 4-bit data nibbles according to the 4B/5B table. The
translated data is presented on the RXD[3:0] signal lines. The SSD, /J/K/, is translated to “0101 0101”
as the first 2 nibbles of the MAC preamble. Reception of the SSD causes the transceiver to assert the
RXDV signal, indicating that valid data is available on the RXD bus. Successive valid code-groups are
translated to data nibbles. Reception of either the End of Stream Delimiter (ESD) consisting of the /T/R/
symbols, or at least two /I/ symbols causes the transceiver to de-assert carrier sense and RXDV.
These symbols are not translated into data.
The decoding process may be bypassed by clearing bit 6 of register 31. When the decoding is
bypassed the 5th receive data bit is driven out on RXER/RXD4/PHYAD0. Decoding may be bypassed
only when the MAC interface is in MII mode.
4.3.7
Receive Data Valid Signal
The Receive Data Valid signal (RXDV) indicates that recovered and decoded nibbles are being
presented on the RXD[3:0] outputs synchronous to RXCLK. RXDV becomes active after the /J/K/
delimiter has been recognized and RXD is aligned to nibble boundaries. It remains active until either
the /T/R/ delimiter is recognized or link test indicates failure or SIGDET becomes false.
RXDV is asserted when the first nibble of translated /J/K/ is ready for transfer over the Media
Independent Interface (MII mode).
SMSC LAN8710/LAN8710i
23
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
CLEAR-TEXT
J
K
5
5
5
D
data
data
data
data
T
R
5
5
5
5
5
D
data
data
data
data
Idle
RX_CLK
RX_DV
RXD
Figure 4.3 Relationship Between Received Data and Specific MII Signals
4.3.8
Receiver Errors
During a frame, unexpected code-groups are considered receive errors. Expected code groups are the
DATA set (0 through F), and the /T/R/ (ESD) symbol pair. When a receive error occurs, the RXER
signal is asserted and arbitrary data is driven onto the RXD[3:0] lines. Should an error be detected
during the time that the /J/K/ delimiter is being decoded (bad SSD error), RXER is asserted true and
the value ‘1110’ is driven onto the RXD[3:0] lines. Note that the Valid Data signal is not yet asserted
when the bad SSD error occurs.
4.3.9
100M Receive Data Across the MII/RMII Interface
In MII mode, the 4-bit data nibbles are sent to the MII block. These data nibbles are clocked to the
controller at a rate of 25MHz. The controller samples the data on the rising edge of RXCLK. To ensure
that the setup and hold requirements are met, the nibbles are clocked out of the transceiver on the
falling edge of RXCLK. RXCLK is the 25MHz output clock for the MII bus. It is recovered from the
received data to clock the RXD bus. If there is no received signal, it is derived from the system
reference clock (XTAL1/CLKIN).
When tracking the received data, RXCLK has a maximum jitter of 0.8ns (provided that the jitter of the
input clock, XTAL1/CLKIN, is below 100ps).
In RMII mode, the 2-bit data nibbles are sent to the RMII block. These data nibbles are clocked to the
controller at a rate of 50MHz. The controller samples the data on the rising edge of XTAL1/CLKIN
(REF_CLK). To ensure that the setup and hold requirements are met, the nibbles are clocked out of
the transceiver on the falling edge of XTAL1/CLKIN (REF_CLK).
4.4
10Base-T Transmit
Data to be transmitted comes from the MAC layer controller. The 10Base-T transmitter receives 4-bit
nibbles from the MII at a rate of 2.5MHz and converts them to a 10Mbps serial data stream. The data
stream is then Manchester-encoded and sent to the analog transmitter, which drives a signal onto the
twisted pair via the external magnetics.
The 10M transmitter uses the following blocks:
4.4.1
„
MII (digital)
„
TX 10M (digital)
„
10M Transmitter (analog)
„
10M PLL (analog)
10M Transmit Data Across the MII/RMII Interface
The MAC controller drives the transmit data onto the TXD BUS. For MII, when the controller has driven
TXEN high to indicate valid data, the data is latched by the MII block on the rising edge of TXCLK.
The data is in the form of 4-bit wide 2.5MHz data.
Revision 1.0 (04-15-09)
24
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
In order to comply with legacy 10Base-T MAC/Controllers, in Half-duplex mode the transceiver loops
back the transmitted data, on the receive path. This does not confuse the MAC/Controller since the
COL signal is not asserted during this time. The transceiver also supports the SQE (Heartbeat) signal.
See Section 5.3.2, "Collision Detect," on page 49, for more details.
For RMII, TXD[1:0] shall transition synchronously with respect to REF_CLK. When TXEN is asserted,
TXD[1:0] are accepted for transmission by the LAN8710/LAN8710i. TXD[1:0] shall be “00” to indicate
idle when TXEN is deasserted. Values of TXD[1:0] other than “00” when TXEN is deasserted are
reserved for out-of-band signalling (to be defined). Values other than “00” on TXD[1:0] while TXEN is
deasserted shall be ignored by the LAN8710/LAN8710i.TXD[1:0] shall provide valid data for each
REF_CLK period while TXEN is asserted.
4.4.2
Manchester Encoding
The 4-bit wide data is sent to the TX10M block. The nibbles are converted to a 10Mbps serial NRZI
data stream. The 10M PLL locks onto the external clock or internal oscillator and produces a 20MHz
clock. This is used to Manchester encode the NRZ data stream. When no data is being transmitted
(TXEN is low), the TX10M block outputs Normal Link Pulses (NLPs) to maintain communications with
the remote link partner.
4.4.3
10M Transmit Drivers
The Manchester encoded data is sent to the analog transmitter where it is shaped and filtered before
being driven out as a differential signal across the TXP and TXN outputs.
4.5
10Base-T Receive
The 10Base-T receiver gets the Manchester- encoded analog signal from the cable via the magnetics.
It recovers the receive clock from the signal and uses this clock to recover the NRZI data stream. This
10M serial data is converted to 4-bit data nibbles which are passed to the controller across the MII at
a rate of 2.5MHz.
This 10M receiver uses the following blocks:
4.5.1
„
Filter and SQUELCH (analog)
„
10M PLL (analog)
„
RX 10M (digital)
„
MII (digital)
10M Receive Input and Squelch
The Manchester signal from the cable is fed into the transceiver (on inputs RXP and RXN) via 1:1 ratio
magnetics. It is first filtered to reduce any out-of-band noise. It then passes through a SQUELCH
circuit. The SQUELCH is a set of amplitude and timing comparators that normally reject differential
voltage levels below 300mV and detect and recognize differential voltages above 585mV.
4.5.2
Manchester Decoding
The output of the SQUELCH goes to the RX10M block where it is validated as Manchester encoded
data. The polarity of the signal is also checked. If the polarity is reversed (local RXP is connected to
RXN of the remote partner and vice versa), then this is identified and corrected. The reversed condition
is indicated by the flag “XPOL“, bit 4 in register 27. The 10M PLL is locked onto the received
Manchester signal and from this, generates the received 20MHz clock. Using this clock, the
Manchester encoded data is extracted and converted to a 10MHz NRZI data stream. It is then
converted from serial to 4-bit wide parallel data.
The RX10M block also detects valid 10Base-T IDLE signals - Normal Link Pulses (NLPs) - to maintain
the link.
SMSC LAN8710/LAN8710i
25
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
4.5.3
10M Receive Data Across the MII/RMII Interface
For MII, the 4 bit data nibbles are sent to the MII block. In MII mode, these data nibbles are valid on
the rising edge of the 2.5 MHz RXCLK.
For RMII, the 2bit data nibbles are sent to the RMII block. In RMII mode, these data nibbles are valid
on the rising edge of the RMII REF_CLK.
4.5.4
Jabber Detection
Jabber is a condition in which a station transmits for a period of time longer than the maximum
permissible packet length, usually due to a fault condition, that results in holding the TXEN input for a
long period. Special logic is used to detect the jabber state and abort the transmission to the line, within
45ms. Once TXEN is deasserted, the logic resets the jabber condition.
As shown in Table 5.22, bit 1.1 indicates that a jabber condition was detected.
4.6
MAC Interface
The MII/RMII block is responsible for the communication with the controller. Special sets of hand-shake
signals are used to indicate that valid received/transmitted data is present on the 4 bit receive/transmit
bus.
The device must be configured in MII or RMII mode. This is done by specific pin strapping
configurations.
See Section 4.6.3, "MII vs. RMII Configuration," on page 27 for information on pin strapping and how
the pins are mapped differently.
4.6.1
MII
The MII includes 16 interface signals:
„
transmit data - TXD[3:0]
„
transmit strobe - TXEN
„
transmit clock - TXCLK
„
transmit error - TXER/TXD4
„
receive data - RXD[3:0]
„
receive strobe - RXDV
„
receive clock - RXCLK
„
receive error - RXER/RXD4/PHYAD0
„
collision indication - COL
„
carrier sense - CRS
In MII mode, on the transmit path, the transceiver drives the transmit clock, TXCLK, to the controller.
The controller synchronizes the transmit data to the rising edge of TXCLK. The controller drives TXEN
high to indicate valid transmit data. The controller drives TXER high when a transmit error is detected.
On the receive path, the transceiver drives both the receive data, RXD[3:0], and the RXCLK signal.
The controller clocks in the receive data on the rising edge of RXCLK when the transceiver drives
RXDV high. The transceiver drives RXER high when a receive error is detected.
4.6.2
RMII
The SMSC LAN8710 supports the low pin count Reduced Media Independent Interface (RMII)
intended for use between Ethernet transceivers and Switch ASICs. Under IEEE 802.3, an MII
Revision 1.0 (04-15-09)
26
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
comprised of 16 pins for data and control is defined. In devices incorporating many MACs or
transceiver interfaces such as switches, the number of pins can add significant cost as the port counts
increase. The management interface (MDIO/MDC) is identical to MII. The RMII interface has the
following characteristics:
„
It is capable of supporting 10Mb/s and 100Mb/s data rates
„
A single clock reference is used for both transmit and receive.
„
It provides independent 2 bit wide (di-bit) transmit and receive data paths
„
It uses LVCMOS signal levels, compatible with common digital CMOS ASIC processes
The RMII includes 6 interface signals with one of the signals being optional:
4.6.2.1
„
transmit data - TXD[1:0]
„
transmit strobe - TXEN
„
receive data - RXD[1:0]
„
receive error - RXER (Optional)
„
carrier sense - CRS_DV
„
Reference Clock - (RMII references usually define this signal as REF_CLK)
CRS_DV - Carrier Sense/Receive Data Valid
The CRS_DV is asserted by the LAN8710/LAN8710i when the receive medium is non-idle. CRS_DV
is asserted asynchronously on detection of carrier due to the criteria relevant to the operating mode.
That is, in 10BASE-T mode, when squelch is passed or in 100BASE-X mode when 2 non-contiguous
zeroes in 10 bits are detected, carrier is said to be detected.
Loss of carrier shall result in the deassertion of CRS_DV synchronous to the cycle of REF_CLK which
presents the first di-bit of a nibble onto RXD[1:0] (i.e. CRS_DV is deasserted only on nibble
boundaries). If the LAN8710/LAN8710i has additional bits to be presented on RXD[1:0] following the
initial deassertion of CRS_DV, then the LAN8710/LAN8710i shall assert CRS_DV on cycles of
REF_CLK which present the second di-bit of each nibble and de-assert CRS_DV on cycles of
REF_CLK which present the first di-bit of a nibble. The result is: Starting on nibble boundaries
CRS_DV toggles at 25 MHz in 100Mb/s mode and 2.5 MHz in 10Mb/s mode when CRS ends before
RXDV (i.e. the FIFO still has bits to transfer when the carrier event ends.) Therefore, the MAC can
accurately recover RXDV and CRS.
During a false carrier event, CRS_DV shall remain asserted for the duration of carrier activity. The data
on RXD[1:0] is considered valid once CRS_DV is asserted. However, since the assertion of CRS_DV
is asynchronous relative to REF_CLK, the data on RXD[1:0] shall be “00” until proper receive signal
decoding takes place.
4.6.3
MII vs. RMII Configuration
The LAN8710/LAN8710i must be configured to support the MII or RMII bus for connectivity to the MAC.
This configuration is done through the RXD2/RMIISEL pin.
MII or RMII mode selection is configured based on the strapping of the RXD2/RMIISEL pin as
described in Section 5.3.9.3.
Most of the MII and RMII pins are multiplexed. Table 4.2, "MII/RMII Signal Mapping" describes the
relationship of the related device pins to the MII and RMII mode signal names.
SMSC LAN8710/LAN8710i
27
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 4.2 MII/RMII Signal Mapping
LAN8710 PIN NAME
MII MODE
RMII MODE
TXD0
TXD0
TXD0
TXD1
TXD1
TXD1
TXEN
TXEN
TXEN
RXER/
RXD4/PHYAD0
RXER
RXER
Note 4.2
COL/CRS_DV/MODE2
COL
CRS_DV
RXD0/MODE0
RXD0
RXD0
RXD1/MODE1
RXD1
RXD1
TXD2
TXD2
Note 4.1
TXD3
TXD3
Note 4.1
nINT/TXER/TXD4
TXER/
TXD4
CRS
CRS
RXDV
RXDV
RXD2/RMIISEL
RXD2
RXD3/PHYAD2
RXD3
TXCLK
TXCLK
RXCLK/PHYAD1
RXCLK
XTAL1/CLKIN
XTAL1/CLKIN
REF_CLK
Note 4.1
In RMII mode, this pin needs to tied to VSS.
Note 4.2
The RXER signal is optional on the RMII bus. This signal is required by the transceiver,
but it is optional for the MAC. The MAC can choose to ignore or not use this signal.
The RMII REF_CLK is a continuous clock that provides the timing reference for CRS_DV, RXD[1:0],
TXEN, TXD[1:0] and RXER. The LAN8710 uses REF_CLK as the network clock such that no buffering
is required on the transmit data path. However, on the receive data path, the receiver recovers the
clock from the incoming data stream, and the LAN8710 uses elasticity buffering to accommodate for
differences between the recovered clock and the local REF_CLK.
4.7
Auto-negotiation
The purpose of the Auto-negotiation function is to automatically configure the transceiver to the
optimum link parameters based on the capabilities of its link partner. Auto-negotiation is a mechanism
for exchanging configuration information between two link-partners and automatically selecting the
highest performance mode of operation supported by both sides. Auto-negotiation is fully defined in
clause 28 of the IEEE 802.3 specification.
Once auto-negotiation has completed, information about the resolved link can be passed back to the
controller via the Serial Management Interface (SMI). The results of the negotiation process are
reflected in the Speed Indication bits in register 31, as well as the Link Partner Ability Register
(Register 5).
Revision 1.0 (04-15-09)
28
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
The auto-negotiation protocol is a purely physical layer activity and proceeds independently of the MAC
controller.
The advertised capabilities of the transceiver are stored in register 4 of the SMI registers. The default
advertised by the transceiver is determined by user-defined on-chip signal options.
The following blocks are activated during an Auto-negotiation session:
„
Auto-negotiation (digital)
„
100M ADC (analog)
„
100M PLL (analog)
„
100M equalizer/BLW/clock recovery (DSP)
„
10M SQUELCH (analog)
„
10M PLL (analog)
„
10M Transmitter (analog)
When enabled, auto-negotiation is started by the occurrence of one of the following events:
„
Hardware reset
„
Software reset
„
Power-down reset
„
Link status down
„
Setting register 0, bit 9 high (auto-negotiation restart)
On detection of one of these events, the transceiver begins auto-negotiation by transmitting bursts of
Fast Link Pulses (FLP). These are bursts of link pulses from the 10M transmitter. They are shaped as
Normal Link Pulses and can pass uncorrupted down CAT-3 or CAT-5 cable. A Fast Link Pulse Burst
consists of up to 33 pulses. The 17 odd-numbered pulses, which are always present, frame the FLP
burst. The 16 even-numbered pulses, which may be present or absent, contain the data word being
transmitted. Presence of a data pulse represents a “1”, while absence represents a “0”.
The data transmitted by an FLP burst is known as a “Link Code Word.” These are defined fully in IEEE
802.3 clause 28. In summary, the transceiver advertises 802.3 compliance in its selector field (the first
5 bits of the Link Code Word). It advertises its technology ability according to the bits set in register 4
of the SMI registers.
There are 4 possible matches of the technology abilities. In the order of priority these are:
„
100M Full Duplex (Highest priority)
„
100M Half Duplex
„
10M Full Duplex
„
10M Half Duplex
If the full capabilities of the transceiver are advertised (100M, Full Duplex), and if the link partner is
capable of 10M and 100M, then auto-negotiation selects 100M as the highest performance mode. If
the link partner is capable of Half and Full duplex modes, then auto-negotiation selects Full Duplex as
the highest performance operation.
Once a capability match has been determined, the link code words are repeated with the acknowledge
bit set. Any difference in the main content of the link code words at this time will cause auto-negotiation
to re-start. Auto-negotiation will also re-start if not all of the required FLP bursts are received.
The capabilities advertised during auto-negotiation by the transceiver are initially determined by the
logic levels latched on the MODE[2:0] bus after reset completes. This bus can also be used to disable
auto-negotiation on power-up.
SMSC LAN8710/LAN8710i
29
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Writing register 4 bits [8:5] allows software control of the capabilities advertised by the transceiver.
Writing register 4 does not automatically re-start auto-negotiation. Register 0, bit 9 must be set before
the new abilities will be advertised. Auto-negotiation can also be disabled via software by clearing
register 0, bit 12.
The LAN8710/LAN8710i does not support “Next Page” capability.
4.7.1
Parallel Detection
If the LAN8710/LAN8710i is connected to a device lacking the ability to auto-negotiate (i.e. no FLPs
are detected), it is able to determine the speed of the link based on either 100M MLT-3 symbols or
10M Normal Link Pulses. In this case the link is presumed to be Half Duplex per the IEEE standard.
This ability is known as “Parallel Detection.” This feature ensures interoperability with legacy link
partners. If a link is formed via parallel detection, then bit 0 in register 6 is cleared to indicate that the
Link Partner is not capable of auto-negotiation. The controller has access to this information via the
management interface. If a fault occurs during parallel detection, bit 4 of register 6 is set.
Register 5 is used to store the Link Partner Ability information, which is coded in the received FLPs.
If the Link Partner is not auto-negotiation capable, then register 5 is updated after completion of parallel
detection to reflect the speed capability of the Link Partner.
4.7.2
Re-starting Auto-negotiation
Auto-negotiation can be re-started at any time by setting register 0, bit 9. Auto-negotiation will also restart if the link is broken at any time. A broken link is caused by signal loss. This may occur because
of a cable break, or because of an interruption in the signal transmitted by the Link Partner. Autonegotiation resumes in an attempt to determine the new link configuration.
If the management entity re-starts Auto-negotiation by writing to bit 9 of the control register, the
LAN8710/LAN8710i will respond by stopping all transmission/receiving operations. Once the
break_link_timer is done, in the Auto-negotiation state-machine (approximately 1200ms) the autonegotiation will re-start. The Link Partner will have also dropped the link due to lack of a received
signal, so it too will resume auto-negotiation.
4.7.3
Disabling Auto-negotiation
Auto-negotiation can be disabled by setting register 0, bit 12 to zero. The device will then force its
speed of operation to reflect the information in register 0, bit 13 (speed) and register 0, bit 8 (duplex).
The speed and duplex bits in register 0 should be ignored when auto-negotiation is enabled.
4.7.4
Half vs. Full Duplex
Half Duplex operation relies on the CSMA/CD (Carrier Sense Multiple Access / Collision Detect)
protocol to handle network traffic and collisions. In this mode, the carrier sense signal, CRS, responds
to both transmit and receive activity. In this mode, If data is received while the transceiver is
transmitting, a collision results.
In Full Duplex mode, the transceiver is able to transmit and receive data simultaneously. In this mode,
CRS responds only to receive activity. The CSMA/CD protocol does not apply and collision detection
is disabled.
4.8
HP Auto-MDIX Support
HP Auto-MDIX facilitates the use of CAT-3 (10 Base-T) or CAT-5 (100 Base-T) media UTP interconnect
cable without consideration of interface wiring scheme. If a user plugs in either a direct connect LAN
cable, or a cross-over patch cable, as shown in Figure 4.4, the SMSC LAN8710/LAN8710i Auto-MDIX
transceiver is capable of configuring the TXP/TXN and RXP/RXN pins for correct transceiver operation.
Revision 1.0 (04-15-09)
30
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
The internal logic of the device detects the TX and RX pins of the connecting device. Since the RX
and TX line pairs are interchangeable, special PCB design considerations are needed to accommodate
the symmetrical magnetics and termination of an Auto-MDIX design.
The Auto-MDIX function can be disabled using the Special Control/Status Indications register (bit
27.15).
Figure 4.4 Direct Cable Connection vs. Cross-over Cable Connection
4.9
Internal +1.2V Regulator Disable
One feature of the flexPWR technology is the ability to configure the internal 1.2V regulator off. When
the regulator is disabled, external 1.2V must be supplied to VDDCR. This makes it possible to reduce
total system power, since an external switching regulator with greater efficiency than the internal linear
regulator may be used to provide the +1.2V to the transceiver circuitry.
4.9.1
Disable the Internal +1.2V Regulator
To disable the +1.2V internal regulator, a pullup strapping resistor is connected from LED1/REGOFF
to VDD2A. At power-on, after both VDDIO and VDD2A are within specification, the transceiver will
sample the LED1/REGOFF pin to determine if the internal regulator should turn on. If the pin is
sampled at a voltage greater than VIH, then the internal regulator is disabled, and the system must
supply +1.2V to the VDDCR pin. As described in Section 4.9.2, when the LED1/REGOFF pin is left
floating or connected to VSS, then the internal regulator is enabled and the system is not required to
supply +1.2V to the VDDCR pin.
4.9.2
Enable the Internal +1.2V Regulator
The 1.2V for VDDCR is supplied by the on-chip regulator unless the transceiver is configured for
regulator off mode using the LED1/REGOFF pin as described in Section 4.9.1. By default, the internal
+1.2V regulator is enabled when the LED1/REGOFF pin is floating. As shown in Table 7.10, an internal
pull-down resistor straps the regulator on if the LED1/REGOFF pin is floating.
During VDDIO and VDDA power-on, if the LED1/REGOFF pin is sampled below VIL, then the internal
+1.2V regulator will turn on and operate with power from the VDD2A pin.
SMSC LAN8710/LAN8710i
31
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
4.10
nINTSEL Strapping and LED Polarity Selection
The nINT, TXER, and TXD4 functions share a common pin. There are two functional modes for this
pin, the TXER/TXD4 mode and nINT (interrupt) mode.
The nINTSEL pin is shared with the LED2 pin. The LED2 output will automatically change polarity
based on the presence of an external pull-down resistor. If the LED pin is pulled high (by the internal
pull-up resistor) to select a logical high for nINTSEL, then the LED output will be active low. If the LED
pin is pulled low by an external pull-down resistor to select a logical low nINTSEL, the LED output will
then be an active high output.
To set nINTSEL without LEDs, float the pin to set nINTSEL high or pull-down the pin with an external
resistor to GND to set nINTSEL low. See Figure 4.5.
The LED2/nINTSEL pin is latched on the rising edge of the nRST. The default setting is to float the
pin high for nINT mode.
nINTSEL = 1
LED output = active low
nINTSEL = 0
LED output = active high
VDD2A
LED2/nINTSEL
10K
~270 ohms
~270 ohms
LED2/nINTSEL
Figure 4.5 nINTSEL Strapping on LED2
4.11
REGOFF and LED Polarity Selection
The REGOFF configuration pin is shared with the LED1 pin. The LED1 output will automatically
change polarity based on the presence of an external pull-up resistor. If the LED pin is pulled high to
VDD2A by an external pull-up resistor to select a logical high for REGOFF, then the LED output will
be active low. If the LED pin is pulled low by the internal pull-down resistor to select a logical low for
REGOFF, the LED output will then be an active high output.
To set REGOFF without LEDs, pull-up the pin with an external resistor to VDDIO to disable the
regulator. See Figure 4.6.
Revision 1.0 (04-15-09)
32
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
REGOFF = 0
LED output = active high
REGOFF = 1 (Regulator OFF)
LED output = active low
VDD2A
LED1/REGOFF
10K
~270 ohms
~270 ohms
LED1/REGOFF
Figure 4.6 REGOFF Configuration on LED1
4.12
PHY Address Strapping
The PHY ADDRESS bits are latched into an internal register at the end of a hardware reset. The 3bit address word[2:0] is input on the PHYAD[2:0] pins. The default setting is 3'b000 as described in
Section 5.3.9.1.
4.13
Variable Voltage I/O
The Digital I/O pins on the LAN8710/LAN8710i are variable voltage to take advantage of low power
savings from shrinking technologies. These pins can operate from a low I/O voltage of +1.8V-10% up
to +3.3V+10%. The I/O voltage the System Designer applies on VDDIO needs to maintain its value
with a tolerance of ± 10%. Varying the voltage up or down, after the transceiver has completed poweron reset can cause errors in the transceiver operation.
4.14
Transceiver Management Control
The Management Control module includes 3 blocks:
4.14.1
„
Serial Management Interface (SMI)
„
Management Registers Set
„
Interrupt
Serial Management Interface (SMI)
The Serial Management Interface is used to control the LAN8710/LAN8710i and obtain its status. This
interface supports registers 0 through 6 as required by Clause 22 of the 802.3 standard, as well as
“vendor-specific” registers 16 to 31 allowed by the specification. Non-supported registers (7 to 15) will
be read as hexadecimal “FFFF”.
At the system level there are 2 signals, MDIO and MDC where MDIO is bi-directional open-drain and
MDC is the clock.
A special feature (enabled by register 17 bit 3) forces the transceiver to disregard the PHY-Address in
the SMI packet causing the transceiver to respond to any address. This feature is useful in multi-PHY
SMSC LAN8710/LAN8710i
33
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
applications and in production testing, where the same register can be written in all the transceivers
using a single write transaction.
The MDC signal is an aperiodic clock provided by the station management controller (SMC). The MDIO
signal receives serial data (commands) from the controller SMC, and sends serial data (status) to the
SMC. The minimum time between edges of the MDC is 160 ns. There is no maximum time between
edges.
The minimum cycle time (time between two consecutive rising or two consecutive falling edges) is 400
ns. These modest timing requirements allow this interface to be easily driven by the I/O port of a
microcontroller.
The data on the MDIO line is latched on the rising edge of the MDC. The frame structure and timing
of the data is shown in Figure 4.7 and Figure 4.8.
The timing relationships of the MDIO signals are further described in Section 6.1, "Serial Management
Interface (SMI) Timing," on page 55.
Read Cycle
MDC
MDI0
32 1's
Preamble
0
1
Start of
Frame
1
0
OP
Code
A4 A3 A2 A1 A0 R4 R3 R2 R1 R0
PHY Address
Register Address
D15
D14
Turn
Around
...
...
D1
D0
Data
Data From Phy
Data To Phy
Figure 4.7 MDIO Timing and Frame Structure - READ Cycle
Write Cycle
MDC
MDIO
32 1's
Preamble
0
1
Start of
Frame
0
1
OP
Code
A4 A3 A2 A1 A0 R4 R3 R2 R1 R0
PHY Address
Register Address
D15
Turn
Around
D14
...
...
D1
D0
Data
Data To Phy
Figure 4.8 MDIO Timing and Frame Structure - WRITE Cycle
Revision 1.0 (04-15-09)
34
DATASHEET
SMSC LAN8710/LAN8710i
Table 5.1 Control Register: Register 0 (Basic)
15
14
13
12
11
10
9
8
7
6
Reset
Loopback
Speed
Select
A/N
Enable
Power
Down
Isolate
Restart A/N
Duplex
Mode
Collision
Test
5
4
3
2
1
0
Reserved
Table 5.2 Status Register: Register 1 (Basic)
14
13
12
11
100Base
-T4
100Base
-TX
Full
Duplex
100Base
-TX
Half
Duplex
10BaseT
Full
Duplex
10BaseT
Half
Duplex
35
DATASHEET
15
10
9
8
7
6
Reserved
5
4
3
2
1
0
A/N
Complete
Remote
Fault
A/N
Ability
Link
Status
Jabber
Detect
Extended
Capability
4
3
2
1
0
3
2
1
0
Table 5.3 PHY ID 1 Register: Register 2 (Extended)
15
14
13
12
11
10
9
8
7
6
5
PHY ID Number (Bits 3-18 of the Organizationally Unique Identifier - OUI)
Table 5.4 PHY ID 2 Register: Register 3 (Extended)
15
14
13
12
11
10
SMSC LAN8710/LAN8710i
PHY ID Number (Bits 19-24 of the Organizationally Unique
Identifier - OUI)
9
8
7
6
Manufacturer Model Number
5
4
Manufacturer Revision Number
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Revision 1.0 (04-15-09)
Chapter 5 SMI Register Mapping
15
14
13
12
11
Next
Page
Reserved
Remote
Fault
Reserved
10
Pause
Operation
9
8
7
6
5
4
100BaseT4
100BaseTX
Full
Duplex
100BaseTX
10BaseT
Full
Duplex
10BaseT
3
2
1
0
IEEE 802.3 Selector
Field
Table 5.6 Auto-Negotiation Link Partner Base Page Ability Register: Register 5 (Extended)
14
13
12
Next
Page
Acknowledge
Remote
Fault
11
Reserved
10
9
8
7
6
5
4
Pause
100BaseT4
100Base-TX
Full Duplex
100BaseTX
10Base-T
Full
Duplex
10BaseT
3
2
1
0
IEEE 802.3 Selector Field
Table 5.7 Auto-Negotiation Expansion Register: Register 6 (Extended)
15
14
13
12
11
10
9
8
7
6
5
Reserved
4
3
2
1
0
Parallel
Detect
Fault
Link
Partner
Next Page
Able
Next Page
Able
Page
Received
Link
Partner
A/N Able
36Revision 1.0 (04-15-09)
DATASHEET
15
Table 5.8 Register 15 (Extended)
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
4
3
2
1
0
IEEE Reserved
Table 5.9 Silicon Revision Register 16: Vendor-Specific
15
14
13
12
Reserved
11
10
9
8
7
Silicon Revision
6
5
Reserved
SMSC LAN8710/LAN8710i
Datasheet
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Table 5.5 Auto-Negotiation Advertisement: Register 4 (Extended)
1
5
14
RSVD
13
12
11
10
9
8
EDPWRDOWN
RSVD
LOWSQEN
MDPREBP
FARLOOPBACK
7
RSVD
6
5
ALTINT
4
RSVD
3
2
1
0
PHYADBP
Force
Good
Link
Status
ENERGYON
RSVD
RSVD = Reserved
Table 5.11 Special Modes Register 18: Vendor-Specific
15
14
13
Reserved
MIIMODE
12
11
10
9
8
7
6
Reserved
5
4
3
2
MODE
1
0
PHYAD
37
DATASHEET
Table 5.12 Register 24: Vendor-Specific
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
5
4
3
2
1
0
4
3
2
1
0
Reserved
Table 5.13 Register 25: Vendor-Specific
15
14
13
12
11
10
9
8
7
6
Reserved
SMSC LAN8710/LAN8710i
Table 5.14 Symbol Error Counter Register 26: Vendor-Specific
15
14
13
12
11
10
9
8
7
Symbol Error Counter
6
5
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Revision 1.0 (04-15-09)
Table 5.10 Mode Control/ Status Register 17: Vendor-Specific
Datasheet
15
14
13
12
11
10
AMDIXCTRL
Reserved
CH_SELECT
Reserved
SQEOFF
9
8
7
6
5
4
Reserved
3
2
XPOL
1
0
Reserved
Table 5.16 Special Internal Testability Control Register 28: Vendor-Specific
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Table 5.17 Interrupt Source Flags Register 29: Vendor-Specific
15
14
13
12
11
10
9
8
Reserved
7
6
5
4
3
2
1
0
INT7
INT6
INT5
INT4
INT3
INT2
INT1
Reserved
Table 5.18 Interrupt Mask Register 30: Vendor-Specific
15
14
13
12
11
10
9
8
7
6
5
Reserved
4
3
2
1
Mask Bits
38Revision 1.0 (04-15-09)
DATASHEET
Reserved
0
Reserved
Table 5.19 PHY Special Control/Status Register 31: Vendor-Specific
15
14
Reserved
13
12
Autodone
11
10
Reserved
9
8
7
6
5
GPO2
GPO1
GPO0
Enable 4B5B
Reserved
4
3
Speed Indication
2
1
0
Reserved
Scramble Disable
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Table 5.15 Special Control/Status Indications Register 27: Vendor-Specific
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
The following registers are supported (register numbers are in decimal):
Table 5.20 SMI Register Mapping
REGISTER #
5.1
DESCRIPTION
Group
0
Basic Control Register
Basic
1
Basic Status Register
Basic
2
PHY Identifier 1
Extended
3
PHY Identifier 2
Extended
4
Auto-Negotiation Advertisement Register
Extended
5
Auto-Negotiation Link Partner Ability Register
Extended
6
Auto-Negotiation Expansion Register
Extended
16
Silicon Revision Register
Vendor-specific
17
Mode Control/Status Register
Vendor-specific
18
Special Modes
Vendor-specific
20
Reserved
Vendor-specific
21
Reserved
Vendor-specific
22
Reserved
Vendor-specific
23
Reserved
Vendor-specific
26
Symbol Error Counter Register
Vendor-specific
27
Control / Status Indication Register
Vendor-specific
28
Special internal testability controls
Vendor-specific
29
Interrupt Source Register
Vendor-specific
30
Interrupt Mask Register
Vendor-specific
31
PHY Special Control/Status Register
Vendor-specific
SMI Register Format
The mode key is as follows:
„
RW = Read/write,
„
SC = Self clearing,
„
WO = Write only,
„
RO = Read only,
„
LH = Latch high, clear on read of register,
„
LL = Latch low, clear on read of register,
„
NASR = Not Affected by Software Reset
„
X = Either a 1 or 0.
SMSC LAN8710/LAN8710i
39
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.21 Register 0 - Basic Control
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
0.15
Reset
1 = software reset. Bit is self-clearing. For best results,
when setting this bit do not set other bits in this
register. The configuration (as described in
Section 5.3.9.2) is set from the register bit values,
and not from the mode pins.
RW/
SC
0
0.14
Loopback
1 = loopback mode,
0 = normal operation
RW
0
0.13
Speed Select
1 = 100Mbps,
0 = 10Mbps.
Ignored if Auto Negotiation is enabled (0.12 = 1).
RW
Set by
MODE[2:0]
bus
0.12
AutoNegotiation
Enable
1 = enable auto-negotiate process
(overrides 0.13 and 0.8)
0 = disable auto-negotiate process
RW
Set by
MODE[2:0]
bus
0.11
Power Down
1 = General power down mode,
0 = normal operation
RW
0
0.10
Isolate
1 = electrical isolation of transceiver from MII
0 = normal operation
RW
0
0.9
Restart AutoNegotiate
1 = restart auto-negotiate process
0 = normal operation. Bit is self-clearing.
RW/
SC
0
0.8
Duplex Mode
1 = Full duplex,
0 = Half duplex.
Ignored if Auto Negotiation is enabled (0.12 = 1).
RW
Set by
MODE[2:0]
bus
0.7
Collision Test
1 = enable COL test,
0 = disable COL test
RW
0
0.6:0
Reserved
RO
0
MODE
DEFAULT
1 = T4 able,
0 = no T4 ability
RO
0
Table 5.22 Register 1 - Basic Status
ADDRESS
NAME
1.15
100Base-T4
1.14
100Base-TX Full
Duplex
1 = TX with full duplex,
0 = no TX full duplex ability
RO
1
1.13
100Base-TX Half
Duplex
1 = TX with half duplex,
0 = no TX half duplex ability
RO
1
1.12
10Base-T Full
Duplex
1 = 10Mbps with full duplex
0 = no 10Mbps with full duplex ability
RO
1
1.11
10Base-T Half
Duplex
1 = 10Mbps with half duplex
0 = no 10Mbps with half duplex ability
RO
1
1.10:6
Reserved
1.5
Auto-Negotiate
Complete
1 = auto-negotiate process completed
0 = auto-negotiate process not completed
RO
0
Revision 1.0 (04-15-09)
DESCRIPTION
40
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.22 Register 1 - Basic Status (continued)
ADDRESS
NAME
DESCRIPTION
1.4
Remote Fault
1.3
Auto-Negotiate
Ability
1.2
Link Status
1.1
Jabber Detect
1.0
Extended
Capabilities
MODE
DEFAULT
1 = remote fault condition detected
0 = no remote fault
RO/
LH
0
1 = able to perform auto-negotiation function
0 = unable to perform auto-negotiation function
RO
1
1 = link is up,
0 = link is down
RO/
LL
X
1 = jabber condition detected
0 = no jabber condition detected
RO/
LH
X
1 = supports extended capabilities registers
0 = does not support extended capabilities registers
RO
1
Table 5.23 Register 2 - PHY Identifier 1
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
2.15:0
PHY ID Number
Assigned to the 3rd through 18th bits of the
Organizationally Unique Identifier (OUI), respectively.
OUI=00800Fh
RW
0007h
MODE
DEFAULT
Assigned to the 19th through 24th bits of the OUI.
RW
30h
Six-bit manufacturer’s model number.
RW
0Fh
Four-bit manufacturer’s revision number.
RW
DEVICE
REV
MODE
DEFAULT
RO
0
RO
0
1 = remote fault detected,
0 = no remote fault
RW
0
00 = No PAUSE
01= Symmetric PAUSE
10= Asymmetric PAUSE toward link partner
11 = Both Symmetric PAUSE and Asymmetric
PAUSE toward local device
R/W
00
Table 5.24 Register 3 - PHY Identifier 2
ADDRESS
NAME
DESCRIPTION
3.15:10
PHY ID Number
3.9:4
Model Number
3.3:0
Revision Number
Table 5.25 Register 4 - Auto Negotiation Advertisement
ADDRESS
NAME
4.15
Next Page
4.14
Reserved
4.13
Remote Fault
4.12
Reserved
4.11:10
Pause Operation
SMSC LAN8710/LAN8710i
DESCRIPTION
1 = next page capable,
0 = no next page ability
This Phy does not support next page ability.
41
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.25 Register 4 - Auto Negotiation Advertisement (continued)
ADDRESS
NAME
4.9
100Base-T4
4.8
100Base-TX Full
Duplex
4.7
100Base-TX
4.6
10Base-T Full
Duplex
4.5
4.4:0
DESCRIPTION
MODE
DEFAULT
1 = T4 able,
0 = no T4 ability
This Phy does not support 100Base-T4.
RO
0
1 = TX with full duplex,
0 = no TX full duplex ability
RW
Set by
MODE[2:0]
bus
1 = TX able,
0 = no TX ability
RW
1
1 = 10Mbps with full duplex
0 = no 10Mbps with full duplex ability
RW
Set by
MODE[2:0]
bus
10Base-T
1 = 10Mbps able,
0 = no 10Mbps ability
RW
Set by
MODE[2:0]
bus
Selector Field
[00001] = IEEE 802.3
RW
00001
Table 5.26 Register 5 - Auto Negotiation Link Partner Ability
ADDRESS
NAME
5.15
Next Page
5.14
MODE
DEFAULT
1 = “Next Page” capable,
0 = no “Next Page” ability
This Phy does not support next page ability.
RO
0
Acknowledge
1 = link code word received from partner
0 = link code word not yet received
RO
0
5.13
Remote Fault
1 = remote fault detected,
0 = no remote fault
RO
0
5.12:11
Reserved
RO
0
5.10
Pause Operation
1 = Pause Operation is supported by remote MAC,
0 = Pause Operation is not supported by remote MAC
RO
0
5.9
100Base-T4
1 = T4 able,
0 = no T4 ability.
This Phy does not support T4 ability.
RO
0
5.8
100Base-TX Full
Duplex
1 = TX with full duplex,
0 = no TX full duplex ability
RO
0
5.7
100Base-TX
1 = TX able,
0 = no TX ability
RO
0
5.6
10Base-T Full
Duplex
1 = 10Mbps with full duplex
0 = no 10Mbps with full duplex ability
RO
0
5.5
10Base-T
1 = 10Mbps able,
0 = no 10Mbps ability
RO
0
5.4:0
Selector Field
[00001] = IEEE 802.3
RO
00001
Revision 1.0 (04-15-09)
DESCRIPTION
42
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.27 Register 6 - Auto Negotiation Expansion
ADDRESS
NAME
6.15:5
Reserved
6.4
Parallel Detection
Fault
6.3
DESCRIPTION
MODE
DEFAULT
RO
0
1 = fault detected by parallel detection logic
0 = no fault detected by parallel detection logic
RO/
LH
0
Link Partner Next
Page Able
1 = link partner has next page ability
0 = link partner does not have next page ability
RO
0
6.2
Next Page Able
1 = local device has next page ability
0 = local device does not have next page ability
RO
0
6.1
Page Received
1 = new page received
0 = new page not yet received
RO/
LH
0
6.0
Link Partner AutoNegotiation Able
1 = link partner has auto-negotiation ability
0 = link partner does not have auto-negotiation ability
RO
0
MODE
DEFAULT
RO
0
RO
0001
RO
0
MODE
DEFAULT
Write as 0; ignore on read.
RW
0
Enable the Energy Detect Power-Down mode:
0 = Energy Detect Power-Down is disabled
1 = Energy Detect Power-Down is enabled
RW
0
Write as 0, ignore on read
RW
0
Table 5.28 Register 16 - Silicon Revision
ADDRESS
NAME
16.15:10
Reserved
16.9:6
Silicon Revision
16.5:0
Reserved
DESCRIPTION
Four-bit silicon revision identifier.
Table 5.29 Register 17 - Mode Control/Status
ADDRESS
NAME
17.15:14
Reserved
17.13
EDPWRDOWN
17.12
Reserved
17.11
LOWSQEN
The Low_Squelch signal is equal to LOWSQEN AND
EDPWRDOWN.
Low_Squelch = 1 implies a lower threshold
(more sensitive).
Low_Squelch = 0 implies a higher threshold
(less sensitive).
RW
0
17.10
MDPREBP
Management Data Preamble Bypass:
0 – detect SMI packets with Preamble
1 – detect SMI packets without preamble
RW
0
17.9
FARLOOPBACK
Force the module to the FAR Loop Back mode, i.e. all
the received packets are sent back simultaneously (in
100Base-TX only). This bit is only active in RMII
mode, as described in Section 5.3.8.2. This mode
works even if MII Isolate (0.10) is set.
RW
0
17.8:7
Reserved
Write as 0, ignore on read.
RW
00
SMSC LAN8710/LAN8710i
DESCRIPTION
43
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.29 Register 17 - Mode Control/Status (continued)
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
17.6
ALTINT
Alternate Interrupt Mode.
0 = Primary interrupt system enabled (Default).
1 = Alternate interrupt system enabled.
See Section 5.2, "Interrupt Management," on page 47.
RW
0
17.5:4
Reserved
Write as 0, ignore on read.
RW
00
17.3
PHYADBP
1 = PHY disregards PHY address in SMI access
write.
RW
0
17.2
Force
Good Link Status
0 = normal operation;
1 = force 100TX- link active;
RW
0
ENERGYON – indicates whether energy is detected
on the line (see Section 5.3.5.2, "Energy Detect
Power-Down," on page 50); it goes to “0” if no valid
energy is detected within 256ms. Reset to “1” by
hardware reset, unaffected by SW reset.
RO
X
Write as 0. Ignore on read.
RW
0
MODE
DEFAULT
RW
0
Note:
17.1
ENERGYON
17.0
Reserved
This bit should be set only during lab testing
Table 5.30 Register 18 - Special Modes
ADDRESS
NAME
DESCRIPTION
18.15
Reserved
Write as 0, ignore on read.
18.14
MIIMODE
MII Mode: set the mode of the digital interface, as
described in Section 5.3.9.3:
0 – MII interface.
1 – RMII interface
RW,
NASR
X
18.13:8
Reserved
Write as 0, ignore on read.
RW,
NASR
000000
18.7:5
MODE
Transceiver Mode of operation. Refer to Section
5.3.9.2, "Mode Bus – MODE[2:0]," on page 53 for
more details.
RW,
NASR
XXX
18.4:0
PHYAD
PHY Address.
The PHY Address is used for the SMI address and for
the initialization of the Cipher (Scrambler) key. Refer
to Section 5.3.9.1, "Physical Address Bus PHYAD[2:0]," on page 52 for more details.
RW,
NASR
PHYAD
Table 5.31 Register 26 - Symbol Error Counter
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
26.15:0
Sym_Err_Cnt
100Base-TX receiver-based error register that
increments when an invalid code symbol is received
including IDLE symbols. The counter is incremented
only once per packet, even when the received packet
contains more than one symbol error. The 16-bit
register counts up to 65,536 (216) and rolls over to 0
if incremented beyond that value. This register is
cleared on reset, but is not cleared by reading the
register. It does not increment in 10Base-T mode.
RO
0
Revision 1.0 (04-15-09)
44
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.32 Register 27 - Special Control/Status Indications
ADDRESS
NAME
DESCRIPTION
MODE
DEFAULT
27.15
AMDIXCTRL
HP Auto-MDIX control
0 - Auto-MDIX enable
1 - Auto-MDIX disabled (use 27.13 to control channel)
RW
0
27.14
Reserved
Reserved
RW
0
27.13
CH_SELECT
Manual Channel Select
0 - MDI -TX transmits RX receives
1 - MDIX -TX receives RX transmits
RW
0
27.12
Reserved
Write as 0. Ignore on read.
RW
0
27:11
SQEOFF
Disable the SQE (Signal Quality Error) test
(Heartbeat):
0 - SQE test is enabled.
1 - SQE test is disabled.
RW,
NASR
0
27.10:5
Reserved
Write as 0. Ignore on read.
RW
000000
27.4
XPOL
Polarity state of the 10Base-T:
0 - Normal polarity
1 - Reversed polarity
RO
0
27.3:0
Reserved
Reserved
RO
XXXXb
MODE
DEFAULT
RW
N/A
MODE
DEFAULT
Ignore on read.
RO/
LH
0
Table 5.33 Register 28 - Special Internal Testability Controls
ADDRESS
NAME
28.15:0
Reserved
DESCRIPTION
Do not write to this register. Ignore on read.
Table 5.34 Register 29 - Interrupt Source Flags
ADDRESS
NAME
29.15:8
Reserved
29.7
INT7
1 = ENERGYON generated
0 = not source of interrupt
RO/
LH
X
29.6
INT6
1 = Auto-Negotiation complete
0 = not source of interrupt
RO/
LH
X
29.5
INT5
1 = Remote Fault Detected
0 = not source of interrupt
RO/
LH
X
29.4
INT4
1 = Link Down (link status negated)
0 = not source of interrupt
RO/
LH
X
29.3
INT3
1 = Auto-Negotiation LP Acknowledge
0 = not source of interrupt
RO/
LH
X
29.2
INT2
1 = Parallel Detection Fault
0 = not source of interrupt
RO/
LH
X
SMSC LAN8710/LAN8710i
DESCRIPTION
45
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 5.34 Register 29 - Interrupt Source Flags (continued)
ADDRESS
NAME
29.1
INT1
29.0
Reserved
DESCRIPTION
MODE
DEFAULT
1 = Auto-Negotiation Page Received
0 = not source of interrupt
RO/
LH
X
Ignore on read.
RO/
LH
0
MODE
DEFAULT
Table 5.35 Register 30 - Interrupt Mask
ADDRESS
NAME
DESCRIPTION
30.15:8
Reserved
Write as 0; ignore on read.
RO
0
30.7:1
Mask Bits
1 = interrupt source is enabled
0 = interrupt source is masked
RW
0
30.0
Reserved
Write as 0; ignore on read
RO
0
MODE
DEFAULT
Table 5.36 Register 31 - PHY Special Control/Status
ADDRESS
NAME
DESCRIPTION
31.15:13
Reserved
Write as 0, ignore on read.
RW
0
31.12
Autodone
Auto-negotiation done indication:
0 = Auto-negotiation is not done or disabled (or not
active)
1 = Auto-negotiation is done
RO
0
Note:
This is a duplicate of register 1.5, however
reads to register 31 do not clear status bits.
31.11:10
Reserved
Write as 0, ignore on Read.
RW
XX
31.9:7
GPO[2:0]
General Purpose Output connected to signals
GPO[2:0]
RW
0
31.6
Enable 4B5B
0 = Bypass encoder/decoder.
1 = enable 4B5B encoding/decoding.
MAC Interface must be configured in MII mode.
RW
1
31.5
Reserved
Write as 0, ignore on Read.
RW
0
31.4:2
Speed Indication
HCDSPEED value:
[001]=10Mbps Half-duplex
[101]=10Mbps Full-duplex
[010]=100Base-TX Half-duplex
[110]=100Base-TX Full-duplex
RO
XXX
31.1
Reserved
Write as 0; ignore on Read
RW
0
31.0
Scramble Disable
0 = enable data scrambling
1 = disable data scrambling,
RW
0
Revision 1.0 (04-15-09)
46
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
5.2
Interrupt Management
The Management interface supports an interrupt capability that is not a part of the IEEE 802.3
specification. It generates an active low asynchronous interrupt signal on the nINT output whenever
certain events are detected as setup by the Interrupt Mask Register 30.
The Interrupt system on the SMSC The LAN8710 has two modes, a Primary Interrupt mode and an
Alternative Interrupt mode. Both systems will assert the nINT pin low when the corresponding mask
bit is set, the difference is how they de-assert the output interrupt signal nINT.
The Primary interrupt mode is the default interrupt mode after a power-up or hard reset, the Alternative
interrupt mode would need to be setup again after a power-up or hard reset.
5.2.1
Primary Interrupt System
The Primary Interrupt system is the default interrupt mode, (Bit 17.6 = ‘0’). The Primary Interrupt
System is always selected after power-up or hard reset.
To set an interrupt, set the corresponding mask bit in the interrupt Mask register 30 (see Table 5.37).
Then when the event to assert nINT is true, the nINT output will be asserted.
When the corresponding Event to De-Assert nINT is true, then the nINT will be de-asserted.
Table 5.37 Interrupt Management Table
MASK
INTERRUPT SOURCE
FLAG
INTERRUPT SOURCE
EVENT TO
ASSERT nINT
EVENT TO
DE-ASSERT nINT
30.7
29.7
ENERGYON
17.1
ENERGYON
Rising 17.1
(Note 5.1)
Falling 17.1 or
Reading register 29
30.6
29.6
Auto-Negotiation
complete
1.5
Auto-Negotiate
Complete
Rising 1.5
Falling 1.5 or
Reading register 29
30.5
29.5
Remote Fault
Detected
1.4
Remote Fault
Rising 1.4
Falling 1.4, or
Reading register 1 or
Reading register 29
30.4
29.4
Link Down
1.2
Link Status
Falling 1.2
Reading register 1 or
Reading register 29
30.3
29.3
Auto-Negotiation
LP Acknowledge
5.14
Acknowledge
Rising 5.14
Falling 5.14 or
Read register 29
30.2
29.2
Parallel Detection
Fault
6.4
Parallel
Detection Fault
Rising 6.4
Falling 6.4 or
Reading register 6, or
Reading register 29
or
Re-Auto Negotiate or
Link down
30.1
29.1
Auto-Negotiation
Page Received
6.1
Page Received
Rising 6.1
Falling of 6.1 or
Reading register 6, or
Reading register 29
Re-Auto Negotiate, or
Link Down.
Note 5.1
SMSC LAN8710/LAN8710i
If the mask bit is enabled and nINT has been de-asserted while ENERGYON is still high,
nINT will assert for 256 ms, approximately one second after ENERGYON goes low when
the Cable is unplugged. To prevent an unexpected assertion of nINT, the ENERGYON
interrupt mask should always be cleared as part of the ENERGYON interrupt service
routine.
47
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Note: The ENERGYON bit 17.1 is defaulted to a ‘1’ at the start of the signal acquisition process,
therefore the Interrupt source flag 29.7 will also read as a ‘1’ at power-up. If no signal is
present, then both 17.1 and 29.7 will clear within a few milliseconds.
5.2.2
Alternate Interrupt System
The Alternative method is enabled by writing a ‘1’ to 17.6 (ALTINT).
To set an interrupt, set the corresponding bit of the in the Mask Register 30, (see Table 5.38).
To Clear an interrupt, either clear the corresponding bit in the Mask Register (30), this will de-assert
the nINT output, or Clear the Interrupt Source, and write a ‘1’ to the corresponding Interrupt Source
Flag. Writing a ‘1’ to the Interrupt Source Flag will cause the state machine to check the Interrupt
Source to determine if the Interrupt Source Flag should clear or stay as a ‘1’. If the Condition to DeAssert is true, then the Interrupt Source Flag is cleared, and the nINT is also de-asserted. If the
Condition to De-Assert is false, then the Interrupt Source Flag remains set, and the nINT remains
asserted.
For example 30.7 is set to ‘1’ to enable the ENERGYON interrupt. After a cable is plugged in,
ENERGYON (17.1) goes active and nINT will be asserted low.
To de-assert the nINT interrupt output, either.
1. Clear the ENERGYON bit (17.1), by removing the cable, then writing a ‘1’ to register 29.7.
Or
2. Clear the Mask bit 30.1 by writing a ‘0’ to 30.1.
Table 5.38 Alternative Interrupt System Management Table
MASK
INTERRUPT SOURCE
FLAG
INTERRUPT SOURCE
EVENT TO
ASSERT nINT
CONDITION
TO
DE-ASSERT
BIT TO
CLEAR
nINT
30.7
29.7
ENERGYON
17.1
ENERGYON
Rising 17.1
17.1 low
29.7
30.6
29.6
Auto-Negotiation
complete
1.5
Auto-Negotiate
Complete
Rising 1.5
1.5 low
29.6
30.5
29.5
Remote Fault
Detected
1.4
Remote Fault
Rising 1.4
1.4 low
29.5
30.4
29.4
Link Down
1.2
Link Status
Falling 1.2
1.2 high
29.4
30.3
29.3
Auto-Negotiation
LP Acknowledge
5.14
Acknowledge
Rising 5.14
5.14 low
29.3
30.2
29.2
Parallel
Detection Fault
6.4
Parallel Detection
Fault
Rising 6.4
6.4 low
29.2
30.1
29.1
Auto-Negotiation
Page Received
6.1
Page Received
Rising 6.1
6.1 low
29.1
Note: The ENERGYON bit 17.1 is defaulted to a ‘1’ at the start of the signal acquisition process,
therefore the Interrupt source flag 29.7 will also read as a ‘1’ at power-up. If no signal is
present, then both 17.1 and 29.7 will clear within a few milliseconds.
5.3
Miscellaneous Functions
5.3.1
Carrier Sense
The carrier sense is output on CRS. CRS is a signal defined by the MII specification in the IEEE 802.3u
standard. The LAN8710 asserts CRS based only on receive activity whenever the transceiver is either
Revision 1.0 (04-15-09)
48
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
in repeater mode or full-duplex mode. Otherwise the transceiver asserts CRS based on either transmit
or receive activity.
The carrier sense logic uses the encoded, unscrambled data to determine carrier activity status. It
activates carrier sense with the detection of 2 non-contiguous zeros within any 10 bit span. Carrier
sense terminates if a span of 10 consecutive ones is detected before a /J/K/ Start-of Stream Delimiter
pair. If an SSD pair is detected, carrier sense is asserted until either /T/R/ End–of-Stream Delimiter
pair or a pair of IDLE symbols is detected. Carrier is negated after the /T/ symbol or the first IDLE. If
/T/ is not followed by /R/, then carrier is maintained. Carrier is treated similarly for IDLE followed by
some non-IDLE symbol.
5.3.2
Collision Detect
A collision is the occurrence of simultaneous transmit and receive operations. The COL output is
asserted to indicate that a collision has been detected. COL remains active for the duration of the
collision. COL is changed asynchronously to both RXCLK and TXCLK. The COL output becomes
inactive during full duplex mode.
COL may be tested by setting register 0, bit 7 high. This enables the collision test. COL will be asserted
within 512 bit times of TXEN rising and will be de-asserted within 4 bit times of TXEN falling.
In 10M mode, COL pulses for approximately 10 bit times (1us), 2us after each transmitted packet (deassertion of TXEN). This is the Signal Quality Error (SQE) signal and indicates that the transmission
was successful. The user can disable this pulse by setting bit 11 in register 27.
5.3.3
Isolate Mode
The LAN8710 data paths may be electrically isolated from the MII by setting register 0, bit 10 to a logic
one. In isolation mode, the transceiver does not respond to the TXD, TXEN and TXER inputs, but does
respond to management transactions.
Isolation provides a means for multiple transceivers to be connected to the same MII without contention
occurring. The transceiver is not isolated on power-up (bit 0:10 = 0).
5.3.4
Link Integrity Test
The LAN8710 performs the link integrity test as outlined in the IEEE 802.3u (Clause 24-15) Link
Monitor state diagram. The link status is multiplexed with the 10Mbps link status to form the reportable
link status bit in Serial Management Register 1, and is driven to the LINK LED.
The DSP indicates a valid MLT-3 waveform present on the RXP and RXN signals as defined by the
ANSI X3.263 TP-PMD standard, to the Link Monitor state-machine, using internal signal called
DATA_VALID. When DATA_VALID is asserted the control logic moves into a Link-Ready state, and
waits for an enable from the Auto Negotiation block. When received, the Link-Up state is entered, and
the Transmit and Receive logic blocks become active. Should Auto Negotiation be disabled, the link
integrity logic moves immediately to the Link-Up state, when the DATA_VALID is asserted.
Note that to allow the line to stabilize, the link integrity logic will wait a minimum of 330 μsec from the
time DATA_VALID is asserted until the Link-Ready state is entered. Should the DATA_VALID input be
negated at any time, this logic will immediately negate the Link signal and enter the Link-Down state.
When the 10/100 digital block is in 10Base-T mode, the link status is from the 10Base-T receiver logic.
5.3.5
Power-Down modes
There are 2 power-down modes for the LAN8710 described in the following sections.
SMSC LAN8710/LAN8710i
49
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
5.3.5.1
General Power-Down
This power-down is controlled by register 0, bit 11. In this mode the entire transceiver, except the
management interface, is powered-down and stays in that condition as long as bit 0.11 is HIGH. When
bit 0.11 is cleared, the transceiver powers up and is automatically reset.
5.3.5.2
Energy Detect Power-Down
This power-down mode is activated by setting bit 17.13 to 1. In this mode when no energy is present
on the line the transceiver is powered down, except for the management interface, the SQUELCH
circuit and the ENERGYON logic. The ENERGYON logic is used to detect the presence of valid energy
from 100Base-TX, 10Base-T, or Auto-negotiation signals
In this mode, when the ENERGYON signal is low, the transceiver is powered-down, and nothing is
transmitted. When energy is received - link pulses or packets - the ENERGYON signal goes high, and
the transceiver powers-up. It automatically resets itself into the state it had prior to power-down, and
asserts the nINT interrupt if the ENERGYON interrupt is enabled. The first and possibly the second
packet to activate ENERGYON may be lost.
When 17.13 is low, energy detect power-down is disabled.
5.3.6
Reset
The LAN8710 registers are reset by the Hardware and Software resets. Some SMI register bits are
not cleared by Software reset, and these are marked “NASR” in the register tables. The SMI registers
are not reset by the power-down modes described in Section 5.3.5.
For the first 16us after coming out of reset, the MII will run at 2.5 MHz. After that it will switch to 25
MHz if auto-negotiation is enabled.
5.3.6.1
Hardware Reset
Hardware reset is asserted by driving the nRST input low.
When the nRST input is driven by an external source, it should be held LOW for at least 100 us to
ensure that the transceiver is properly reset. During a hardware reset an external clock must be
supplied to the XTAL1/CLKIN signal.
5.3.6.2
Software Reset
Software reset is activated by writing register 0, bit 15 high. This signal is self- clearing. The SMI
registers are reset except those that are marked “NASR” in the register tables.
The IEEE 802.3u standard, clause 22 (22.2.4.1.1) states that the reset process should be completed
within 0.5s from the setting of this bit.
5.3.7
LED Description
The LAN8710 provides two LED signals. These provide a convenient means to determine the mode
of operation of the transceiver. All LED signals are either active high or active low as described in
Section 4.10 and Section 4.11.
The LED1 output is driven active whenever the LAN8710 detects a valid link, and blinks when CRS is
active (high) indicating activity.
The LED2 output is driven active when the operating speed is 100Mbit/s. This LED will go inactive
when the operating speed is 10Mbit/s or during line isolation (register 31 bit 5).
5.3.8
Loopback Operation
The LAN8710 may be configured for near-end loopback and far loopback.
Revision 1.0 (04-15-09)
50
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
5.3.8.1
Near-end Loopback
Near-end loopback is a mode that sends the digital transmit data back out the receive data signals for
testing purposes as indicated by the blue arrows in Figure 5.1.The near-end loopback mode is enabled
by setting bit register 0 bit 14 to logic one.
A large percentage of the digital circuitry is operational near-end loopback mode, because data is
routed through the PCS and PMA layers into the PMD sublayer before it is looped back. The COL
signal will be inactive in this mode, unless collision test (bit 0.7) is active. The transmitters are powered
down, regardless of the state of TXEN.
TXD
10/100
Ethernet
MAC
X
RXD
Digital
Analog
X
TX
RX
CAT-5
XFMR
SMSC
Ethernet Transceiver
Figure 5.1 Near-end Loopback Block Diagram
5.3.8.2
Far Loopback
This special test mode is only available when operating in RMII mode. When the the RXD2/RMIISEL
pin is configured for MII mode, the SMI can be used to override this setting as described in
Section 5.3.9.3.
Far loopback is a special test mode for MDI (analog) loopback as indicated by the blue arrows in
Figure 5.3. The far loopback mode is enabled by setting bit register 17 bit 9 to logic one. In this mode,
data that is received from the link partner on the MDI is looped back out to the link partner. The digital
interface signals on the local MAC interface are isolated.
Far-end system
10/100
Ethernet
MAC
TXD
RXD
TX
X
X
RX
Digital
XFMR
CAT-5
Link
Partner
Analog
SMSC
Ethernet Transceiver
Figure 5.2 Far Loopback Block Diagram
SMSC LAN8710/LAN8710i
51
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
5.3.8.3
Connector Loopback
The LAN8710/LAN8710i maintains reliable transmission over very short cables, and can be tested in
a connector loopback as shown in Figure 5.3. An RJ45 loopback cable can be used to route the
transmit signals an the output of the transformer back to the receiver inputs, and this loopback will
work at both 10 and 100.
10/100
Ethernet
MAC
TXD
1
2
3
4
5
6
7
8
TX
RXD
RX
Digital
XFMR
Analog
SMSC
RJ45 Loopback Cable.
Created by connecting pin 1 to pin 3
and connecting pin 2 to pin 6.
Ethernet Transceiver
Figure 5.3 Connector Loopback Block Diagram
5.3.9
Configuration Signals
The hardware configuration signals are sampled during the power-on sequence to determine the
physical address and operating mode.
5.3.9.1
Physical Address Bus - PHYAD[2:0]
The PHYAD[2:0] bits are driven high or low to give each PHY a unique address. This address is
latched into an internal register at the end of a hardware reset. In a multi-transceiver application (such
as a repeater), the controller is able to manage each transceiver via the unique address. Each
transceiver checks each management data frame for a matching address in the relevant bits. When a
match is recognized, the transceiver responds to that particular frame. The PHY address is also used
to seed the scrambler. In a multi-Transceiver application, this ensures that the scramblers are out of
synchronization and disperses the electromagnetic radiation across the frequency spectrum.
The LAN8710 SMI address may be configured using hardware configuration to any value between 0
and 7. The user can configure the PHY address using Software Configuration if an address greater
than 7 is required. The PHY address can be written (after SMI communication at some address is
established) using the 10/100 Special Modes register (bits18.[4:0]).
The PHYAD[2:0] hardware configuration pins are multiplexed with other signals as shown in
Table 5.39.
Table 5.39 Pin Names for Address Bits
ADDRESS BIT
PIN NAME
PHYAD[0]
RXER/PHYAD0
PHYAD[1]
RXCLK/PHYAD1
PHYAD[2]
RXD3/PHYAD2
The LAN8710 may be configured to disregard the PHY address in SMI access write by setting the
register bit 17.3 (PHYADBP).
Revision 1.0 (04-15-09)
52
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
5.3.9.2
Mode Bus – MODE[2:0]
The MODE[2:0] bus controls the configuration of the 10/100 digital block. When the nRST pin is
deasserted, the register bit values are loaded according to the MODE[2:0] pins. The 10/100 digital
block is then configured by the register bit values. When a soft reset occurs (bit 0.15) as described in
Table 5.21, the configuration of the 10/100 digital block is controlled by the register bit values, and the
MODE[2:0] pins have no affect.
The LAN8710 mode may be configured using hardware configuration as summarized in Table 5.40.
The user may configure the transceiver mode by writing the SMI registers.
Table 5.40 MODE[2:0] Bus
DEFAULT REGISTER BIT VALUES
MODE[2:0]
MODE DEFINITIONS
REGISTER 0
REGISTER 4
[13,12,10,8]
[8,7,6,5]
000
10Base-T Half Duplex. Auto-negotiation disabled.
0000
N/A
001
10Base-T Full Duplex. Auto-negotiation disabled.
0001
N/A
010
100Base-TX Half Duplex. Auto-negotiation
disabled.
CRS is active during Transmit & Receive.
1000
N/A
011
100Base-TX Full Duplex. Auto-negotiation disabled.
CRS is active during Receive.
1001
N/A
100
100Base-TX Half Duplex is advertised. Autonegotiation enabled.
CRS is active during Transmit & Receive.
1100
0100
101
Repeater mode. Auto-negotiation enabled.
100Base-TX Half Duplex is advertised.
CRS is active during Receive.
1100
0100
110
Power Down mode. In this mode the transceiver will
wake-up in Power-Down mode. The transceiver
cannot be used when the MODE[2:0] bits are set to
this mode. To exit this mode, the MODE bits in
Register 18.7:5(see Table 5.30) must be configured
to some other value and a soft reset must be
issued.
N/A
N/A
111
All capable. Auto-negotiation enabled.
X10X
1111
The MODE[2:0] hardware configuration pins are multiplexed with other signals as shown in Table 5.41.
Table 5.41 Pin Names for Mode Bits
5.3.9.3
MODE BIT
PIN NAME
MODE[0]
RXD0/MODE0
MODE[1]
RXD1/MODE1
MODE[2]
COL/CRS_DV/MODE2
MII/RMII Mode Selection
MII or RMII mode selection is latched on the rising edge of the internal reset (nRESET) based on the
strapping of the RXD2/RMIISEL pin. The default mode is MII with the internal pull-down resistor. To
select RMII mode, pull the RXD2/RMIISEL pin high with an external resistor to VDDIO.
SMSC LAN8710/LAN8710i
53
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
When the nRST pin is deasserted, the register bit 18.14 (MIIMODE) is loaded according to the
RXD2/RMIISEL pin. The mode is then configured by the register bit value. When a soft reset occurs
(bit 0.15) as described in Table 5.21, the MII or RMII mode selection is controlled by the register bit
18.14, and the RXD2/RMIISEL pin has no affect.
Revision 1.0 (04-15-09)
54
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 6 AC Electrical Characteristics
The timing diagrams and limits in this section define the requirements placed on the external signals
of the Phy.
6.1
Serial Management Interface (SMI) Timing
The Serial Management Interface is used for status and control as described in Section 4.14.
T1.1
Clock MDC
T1.2
Data Out MDIO
Valid Data
(Read from PHY)
T1.3
Data In MDIO
T1.4
Valid Data
(Write to PHY)
Figure 6.1 SMI Timing Diagram
Table 6.1 SMI Timing Values
PARAMETER
DESCRIPTION
MIN
T1.1
MDC minimum cycle time
400
T1.2
MDC to MDIO (Read from PHY)
delay
0
T1.3
MDIO (Write to PHY) to MDC setup
10
ns
T1.4
MDIO (Write to PHY) to MDC hold
10
ns
SMSC LAN8710/LAN8710i
55
DATASHEET
TYP
MAX
UNITS
NOTES
ns
30
ns
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.2
MII 10/100Base-TX/RX Timings
6.2.1
MII 100Base-T TX/RX Timings
6.2.1.1
100M MII Receive Timing
Clock Out RX_CLK
T2.1
Data Out RXD[3:0]
RX_DV
RX_ER
T2.2
Valid Data
Figure 6.2 100M MII Receive Timing Diagram
Table 6.2 100M MII Receive Timing Values
PARAMETER
DESCRIPTION
MIN
T2.1
Receive signals setup to RXCLK
rising
10
ns
T2.2
Receive signals hold from RXCLK
rising
10
ns
Revision 1.0 (04-15-09)
TYP
MAX
UNITS
RXCLK frequency
25
MHz
RXCLK Duty-Cycle
50
%
56
DATASHEET
NOTES
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.2.1.2
100M MII Transmit Timing
Clock Out TX_CLK
T3.1
Data In TXD[3:0]
TX_EN
TX_ER
Valid Data
Figure 6.3 100M MII Transmit Timing Diagram
Table 6.3 100M MII Transmit Timing Values
PARAMETER
DESCRIPTION
MIN
TYP
MAX
UNITS
T3.1
Transmit signals required setup to
TXCLK rising
12
ns
Transmit signals required hold
after TXCLK rising
0
ns
TXCLK frequency
25
MHz
TXCLK Duty-Cycle
50
%
SMSC LAN8710/LAN8710i
57
DATASHEET
NOTES
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.2.2
MII 10Base-T TX/RX Timings
6.2.2.1
10M MII Receive Timing
Clock Out RX_CLK
T4.1
Data Out RXD[3:0]
RX_DV
T4.2
Valid Data
Figure 6.4 10M MII Receive Timing Diagram
Table 6.4 10M MII Receive Timing Values
PARAMETER
DESCRIPTION
MIN
TYP
MAX
UNITS
T4.1
Receive signals setup to RXCLK
rising
10
ns
T4.2
Receive signals hold from RXCLK
rising
10
ns
Revision 1.0 (04-15-09)
RXCLK frequency
2.5
MHz
RXCLK Duty-Cycle
50
%
58
DATASHEET
NOTES
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.2.2.2
10M MII Transmit Timing
Clock Out TX_CLK
T5.1
Data In TXD[3:0]
TX_EN
Valid Data
Figure 6.5 10M MII Transmit Timing Diagrams
Table 6.5 10M MII Transmit Timing Values
PARAMETER
DESCRIPTION
MIN
TYP
MAX
UNITS
T5.1
Transmit signals required setup to
TXCLK rising
12
ns
Transmit signals required hold
after TXCLK rising
0
ns
TXCLK frequency
2.5
MHz
TXCLK Duty-Cycle
50
%
SMSC LAN8710/LAN8710i
59
DATASHEET
NOTES
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.3
RMII 10/100Base-TX/RX Timings (50MHz REF_CLK IN)
6.3.1
RMII 100Base-T TX/RX Timings (50MHz REF_CLK IN)
6.3.1.1
100M RMII Receive Timing (50MHz REF_CLK IN)
Clock In CLKIN
T6.1
Data Out RXD[1:0]
CRS_DV
Valid Data
Figure 6.6 100M RMII Receive Timing Diagram (50MHz REF_CLK IN)
Table 6.6 100M RMII Receive Timing Values (50MHz REF_CLK IN)
PARAMETER
DESCRIPTION
MIN
T6.1
Output delay from rising edge of
CLKIN to receive signals output
valid
3
TYP
CLKIN frequency
Revision 1.0 (04-15-09)
50
60
DATASHEET
MAX
UNITS
10
ns
NOTES
MHz
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.3.1.2
100M RMII Transmit Timing (50MHz REF_CLK IN)
Clock In CLKIN
T8.1
Data In TXD[1:0]
TX_EN
T8.2
Valid Data
Figure 6.7 100M RMII Transmit Timing Diagram (50MHz REF_CLK IN)
Table 6.7 100M RMII Transmit Timing Values (50MHz REF_CLK IN)
PARAMETER
DESCRIPTION
MIN
T8.1
Transmit signals required setup to
rising edge of CLKIN
4
ns
T8.2
Transmit signals required hold
after rising edge of CLKIN
2
ns
CLKIN frequency
SMSC LAN8710/LAN8710i
TYP
50
61
DATASHEET
MAX
UNITS
NOTES
MHz
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.3.2
RMII 10Base-T TX/RX Timings (50MHz REF_CLK IN)
6.3.2.1
10M RMII Receive Timing (50MHz REF_CLK IN)
Clock In CLKIN
T9.1
Data Out RXD[1:0]
CRS_DV
Valid Data
Figure 6.8 10M RMII Receive Timing Diagram (50MHz REF_CLK IN)
Table 6.8 10M RMII Receive Timing Values (50MHz REF_CLK IN)
PARAMETER
DESCRIPTION
MIN
T9.1
Output delay from rising edge of
CLKIN to receive signals output
valid
3
TYP
CLKIN frequency
Revision 1.0 (04-15-09)
50
62
DATASHEET
MAX
UNITS
10
ns
NOTES
MHz
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.3.2.2
10M RMII Transmit Timing (50MHz REF_CLK IN)
Clock In CLKIN
T 10.2
T 10.1
Data In TXD[1:0]
TX_EN
Valid Data
Figure 6.9 10M RMII Transmit Timing Diagram (50MHz REF_CLK IN)
Table 6.9 10M RMII Transmit Timing Values (50MHz REF_CLK IN)
PARAMETER
DESCRIPTION
MIN
TYP
T10.1
Transmit signals required setup to
rising edge of CLKIN
4
ns
T10.2
Transmit signals required hold
after rising edge of CLKIN
2
ns
CLKIN frequency
SMSC LAN8710/LAN8710i
50
63
DATASHEET
MAX
UNITS
NOTES
MHz
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.4
RMII CLKIN Requirements
Table 6.10 RMII CLKIN (REF_CLK) Timing Values
PARAMETER
DESCRIPTION
MIN
TYP
CLKIN frequency
50
CLKIN Frequency Drift
CLKIN Duty Cycle
UNITS
NOTES
MHz
± 50
ppm
60
%
150
psec
p-p – not RMS
UNITS
NOTES
40
CLKIN Jitter
6.5
MAX
Reset Timing
T 11.1
nRST
T 11.2
T 11.3
Configuration
Signals
T 11.4
O utput drive
Figure 6.10 Reset Timing Diagram
Table 6.11 Reset Timing Values
PARAMETER
DESCRIPTION
MIN
TYP
MAX
T11.1
Reset Pulse Width
100
us
T11.2
Configuration input setup to
nRST rising
200
ns
T11.3
Configuration input hold after
nRST rising
10
ns
T11.4
Output Drive after nRST rising
20
Revision 1.0 (04-15-09)
64
DATASHEET
800
ns
20 clock cycles for
25 MHz clock
or
40 clock cycles for
50MHz clock
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
6.6
Clock Circuit
LAN8710/LAN8710i can accept either a 25MHz crystal or a 25MHz single-ended clock oscillator
(±50ppm) input. If the single-ended clock oscillator method is implemented, XTAL2 should be left
unconnected and XTAL1/CLKIN should be driven with a nominal 0-3.3V clock signal. See Table 6.12
for the recommended crystal specifications.
Table 6.12 LAN8710/LAN8710i Crystal Specifications
PARAMETER
SYMBOL
MIN
NOM
Crystal Cut
MAX
UNITS
NOTES
AT, typ
Crystal Oscillation Mode
Fundamental Mode
Crystal Calibration Mode
Parallel Resonant Mode
Ffund
-
25.000
-
MHz
Frequency Tolerance @ 25oC
Ftol
-
-
±50
PPM
Note 6.1
Frequency Stability Over Temp
Ftemp
-
-
±50
PPM
Note 6.1
Frequency Deviation Over Time
Fage
-
+/-3 to 5
-
PPM
Note 6.2
-
-
±50
PPM
Note 6.3
Frequency
Total Allowable PPM Budget
Shunt Capacitance
CO
-
7 typ
-
pF
Load Capacitance
CL
-
20 typ
-
pF
Drive Level
PW
300
-
-
uW
Equivalent Series Resistance
R1
-
-
30
Ohm
Operating Temperature Range
Note 6.4
-
Note 6.5
oC
LAN8710/LAN8710i
XTAL1/CLKIN Pin Capacitance
-
3 typ
-
pF
Note 6.6
LAN8710/LAN8710i XTAL2 Pin
Capacitance
-
3 typ
-
pF
Note 6.6
Note 6.1
The maximum allowable values for Frequency Tolerance and Frequency Stability are
application dependant. Since any particular application must meet the IEEE ±50 PPM Total
PPM Budget, the combination of these two values must be approximately ±45 PPM
(allowing for aging).
Note 6.2
Frequency Deviation Over Time is also referred to as Aging.
Note 6.3
The total deviation for the Transmitter Clock Frequency is specified by IEEE 802.3u as
±100 PPM.
Note 6.4
0oC for extended commercial version, -40oC for industrial version.
Note 6.5
+85oC for extended commercial version, +85oC for industrial version.
Note 6.6
This number includes the pad, the bond wire and the lead frame. PCB capacitance is not
included in this value. The XTAL1/CLKIN pin, XTAL2 pin and PCB capacitance values are
required to accurately calculate the value of the two external load capacitors. The total load
capacitance must be equivalent to what the crystal expects to see in the circuit so that the
crystal oscillator will operate at 25.000 MHz.
SMSC LAN8710/LAN8710i
65
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 7 DC Electrical Characteristics
7.1
DC Characteristics
7.1.1
Maximum Guaranteed Ratings
Stresses beyond those listed in may cause permanent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Table 7.1 Maximum Conditions
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
VDD1A,
VDD2A,
VDDIO
Power pins to all other pins.
-0.5
+3.6
V
Digital IO
To VSS ground
-0.5
+3.6
V
VSS
VSS to all other pins
-0.5
+0.5
V
Junction to
Ambient (θJA)
Thermal vias per Layout
Guidelines.
Junction to
Case (θJC)
COMMENT
Table 7.5, “MII Bus
Interface Signals,” on
page 69
48.3
°C/W
10.6
°C/W
Operating
Temperature
LAN8710-AEZG
0
+85
oC
Extended commercial
temperature components.
Operating
Temperature
LAN8710i-AEZG
-40
+85
oC
Industrial temperature
components.
-55
+150
oC
Storage
Temperature
Table 7.2 ESD and LATCH-UP Performance
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
COMMENTS
ESD PERFORMANCE
All Pins
Human Body Model
±5
kV
Device
System
IED61000-4-2 Contact Discharge
±15
kV
3rd party system test
System
IEC61000-4-2 Air-gap Discharge
±15
kV
3rd party system test
LATCH-UP PERFORMANCE
All Pins
EIA/JESD 78, Class II
Revision 1.0 (04-15-09)
150
66
DATASHEET
mA
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
7.1.1.1
Human Body Model (HBM) Performance
HBM testing verifies the ability to withstand the ESD strikes like those that occur during handling and
manufacturing, and is done without power applied to the IC. To pass the test, the device must have
no change in operation or performance due to the event. All pins on the LAN8710 provide +/-5kV HBM
protection.
7.1.1.2
IEC61000-4-2 Performance
The IEC61000-4-2 ESD specification is an international standard that addresses system-level immunity
to ESD strikes while the end equipment is operational. In contrast, the HBM ESD tests are performed
at the device level with the device powered down.
SMSC contracts with Independent laboratories to test the LAN8710 to IEC61000-4-2 in a working
system. Reports are available upon request. Please contact your SMSC representative, and request
information on 3rd party ESD test results. The reports show that systems designed with the LAN8710
can safely dissipate ±15kV air discharges and ±15kV contact discharges per the IEC61000-4-2
specification without additional board level protection.
In addition to defining the ESD tests, IEC 61000-4-2 also categorizes the impact to equipment
operation when the strike occurs (ESD Result Classification). The LAN8710 maintains an ESD Result
Classification 1 or 2 when subjected to an IEC 61000-4-2 (level 4) ESD strike.
Both air discharge and contact discharge test techniques for applying stress conditions are defined by
the IEC61000-4-2 ESD document.
AIR DISCHARGE
To perform this test, a charged electrode is moved close to the system being tested until a spark is
generated. This test is difficult to reproduce because the discharge is influenced by such factors as
humidity, the speed of approach of the electrode, and construction of the test equipment.
CONTACT DISCHARGE
The uncharged electrode first contacts the pin to prepare this test, and then the probe tip is energized.
This yields more repeatable results, and is the preferred test method. The independent test laboratories
contracted by SMSC provide test results for both types of discharge methods.
7.1.2
Operating Conditions
Table 7.3 Recommended Operating Conditions
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
VDD1A, VDD2A
To VSS ground
3.0
3.3
3.6
V
VDDIO
To VSS ground
1.6
3.3
3.6
V
COMMENT
Input Voltage on
Digital Pins
0.0
VDDIO
V
Voltage on Analog I/O
pins (RXP, RXN)
0.0
+3.6V
V
TA LAN8710-AEZG
0
+85
oC
For Extended Commercial
Temperature
TA LAN8710i-AEZG
-40
+85
oC
For Industrial Temperature
Ambient Temperature
SMSC LAN8710/LAN8710i
67
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
7.1.3
Power Consumption
7.1.3.1
Power Consumption Device Only
Power measurements taken over the operating conditions specified. See Section 5.3.5 for a description
of the power down modes.
Table 7.4 Power Consumption Device Only
VDDA3.3
POWER
PINS(MA)
VDDCR
POWER
PIN(MA)
VDDIO
POWER
PIN(MA)
TOTAL
CURRENT
(MA)
TOTAL
POWER
(MW)
Max
27.7
20.2
5.2
53.1
175.2
Typical
25.5
18
4.3
47.8
157.7
Min
22.7
17.5
2.4
42.6
100.2
Note 7.1
Max
10.2
12.9
0.98
24.1
79.5
Typical
9.4
11.4
0.4
21.2
70
Min
9.2
10.9
0.3
20.4
44
Note 7.1
Max
4.5
3
0.3
7.8
25.
Typical
4.3
1.4
0.2
5.9
19.5
Min
3.9
1.3
0
5.2
15.9
Note 7.1
Max
0.4
2.6
0.3
3.3
10.9
Typical
0.3
1.2
0.2
1.7
5.6
Min
0.3
1.1
0
1.4
2.4
Note 7.1
POWER PIN GROUP
100BASE-T /W TRAFFIC
10BASE-T /W TRAFFIC
ENERGY DETECT POWER
DOWN
GENERAL POWER DOWN
Note: The current at VDDCR is either supplied by the internal regulator from current entering at
VDD2A, or from an external 1.2V supply when the internal regulator is disabled.
Note 7.1
This is calculated with full flexPWR features activated: VDDIO = 1.8V and internal regulator
disabled.
Note 7.2
Current measurements do not include power applied to the magnetics or the optional
external LEDs.
Revision 1.0 (04-15-09)
68
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
7.1.4
DC Characteristics - Input and Output Buffers
Table 7.5 MII Bus Interface Signals
NAME
VIH (V)
VIL (V)
IOH
IOL
VOL (V)
VOH (V)
TXD0
0.63 * VDDIO
0.39 * VDDIO
TXD1
0.63 * VDDIO
0.39 * VDDIO
TXD2
0.63 * VDDIO
0.39 * VDDIO
TXD3
0.63 * VDDIO
0.39 * VDDIO
TXEN
0.63 * VDDIO
0.39 * VDDIO
TXCLK
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD0/MODE0
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD1/MODE1
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD2/RMIISEL
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD3/PHYAD2
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXER/RXD4/PHYAD0
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXDV
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXCLK/PHYAD1
-8 mA
+8 mA
+0.4
VDDIO – +0.4
CRS
-8 mA
+8 mA
+0.4
VDDIO – +0.4
COL/CRS_DV/MODE2
-8 mA
+8 mA
+0.4
VDDIO – +0.4
MDC
0.63 * VDDIO
0.39 * VDDIO
MDIO
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
nINT/TXER/TXD4
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
3.6
SMSC LAN8710/LAN8710i
69
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 7.6 LAN Interface Signals
NAME
VIH
VIL
IOH
IOL
VOL
VOH
TXP
TXN
See Table 7.11, “100Base-TX Transceiver Characteristics,” on page 71 and Table 7.12,
“10BASE-T Transceiver Characteristics,” on page 72.
RXP
RXN
Table 7.7 LED Signals
NAME
VIH (V)
VIL (V)
IOH
IOL
VOL (V)
VOH (V)
LED1/REGOFF
0.63 * VDD2A
0.39 * VDD2A
-12 mA
+12 mA
+0.4
VDD2A – +0.4
LED2/nINTSEL
0.63 * VDD2A
0.39 * VDD2A
-12 mA
+12 mA
+0.4
VDD2A – +0.4
Table 7.8 Configuration Inputs
NAME
VIH (V)
VIL (V)
IOH
IOL
VOL (V)
VOH (V)
RXD0/MODE0
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD1/MODE1
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD2/RMIISEL
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXD3/PHYAD2
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXER/RXD4/PHYAD0
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
RXCLK/PHYAD1
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
COL/CRS_DV/MODE2
0.63 * VDDIO
0.39 * VDDIO
-8 mA
+8 mA
+0.4
VDDIO – +0.4
IOH
IOL
VOL (V)
VOH (V)
-8 mA
+8 mA
+0.4
VDDIO – +0.4
Table 7.9 General Signals
NAME
VIH (V)
VIL (V)
nINT/TXER/TXD4
nRST
0.63 * VDDIO
0.39 * VDDIO
XTAL1/CLKIN (Note 7.3)
+1.40 V
0.39 * VDD2A
XTAL2
-
-
Note 7.3
Revision 1.0 (04-15-09)
These levels apply when a 0-3.3V Clock is driven into XTAL1/CLKIN and XTAL2 is floating.
The maximum input voltage on XTAL1/CLKIN is VDD2A + 0.4V.
70
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 7.10 Internal Pull-Up / Pull-Down Configurations
NAME
PULL-UP OR PULL-DOWN
nINT/TXER/TXD4
Pull-up
TXEN
Pull-down
RXD0/MODE0
Pull-up
RXD1/MODE1
Pull-up
RXD2/RMIISEL
Pull-down
RXD3/PHYAD2
Pull-down
RXER/RXD4/PHYAD0
Pull-down
RXCLK/PHYAD1
Pull-down
COL/CRS_DV/MODE2
Pull-up
CRS
Pull-down
LED1/REGOFF
Pull-down
LED2/nINTSEL
Pull-up
MDIO
Pull-up
nRST
Pull-up
Table 7.11 100Base-TX Transceiver Characteristics
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Peak Differential Output Voltage High
VPPH
950
-
1050
mVpk
Note 7.4
Peak Differential Output Voltage Low
VPPL
-950
-
-1050
mVpk
Note 7.4
Signal Amplitude Symmetry
VSS
98
-
102
%
Note 7.4
Signal Rise & Fall Time
TRF
3.0
-
5.0
nS
Note 7.4
Rise & Fall Time Symmetry
TRFS
-
-
0.5
nS
Note 7.4
Duty Cycle Distortion
DCD
35
50
65
%
Note 7.5
Overshoot & Undershoot
VOS
-
-
5
%
1.4
nS
Jitter
Note 7.6
Note 7.4
Measured at the line side of the transformer, line replaced by 100Ω (± 1%) resistor.
Note 7.5
Offset from 16 nS pulse width at 50% of pulse peak
Note 7.6
Measured differentially.
SMSC LAN8710/LAN8710i
71
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Table 7.12 10BASE-T Transceiver Characteristics
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Transmitter Peak Differential Output Voltage
VOUT
2.2
2.5
2.8
V
Note 7.7
Receiver Differential Squelch Threshold
VDS
300
420
585
mV
Note 7.7
Revision 1.0 (04-15-09)
Min/max voltages guaranteed as measured with 100Ω resistive load.
72
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 8 Application Notes
8.1
Application Diagram
The LAN8710 requires few external components. The voltage on the magnetics center tap can range
from 2.5 - 3.3V.
8.1.1
MII Diagram
MII
MDIO
MDC
nINT
LAN8710
10/100 PHY
32-QFN
MII
Mag
RJ45
TXP
TXD[3:0]
TXN
4
TXCLK
TXER
TXEN
RXP
RXN
RXD[3:0]
4
RXCLK
RXDV
XTAL1/CLKIN
25MHz
LED[2:1]
XTAL2
2
nRST
Interface
Figure 8.1 Simplified Application Diagram
SMSC LAN8710/LAN8710i
73
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
8.1.2
Power Supply Diagram
Analog
Supply
3.3V
Power to
magnetics
interface.
6
LAN8710
32-QFN
VDDCR
VDD1A
27
CBYPASS
1uF
VDDDIO
Supply
1.8 - 3.3V
12
VDDIO
VDD2A
1
CBYPASS
CBYPASS
CF
R
19
RBIAS
32
nRST
C
12.1k
VSS
Figure 8.2 High-Level System Diagram for Power
8.1.3
Twisted-Pair Interface Diagram
LAN8710
32-QFN
Analog
Supply
3.3V
VDD2A
49.9 Ohm Resistors
Magnetic
Supply
2.5 - 3.3V
1
CBYPASS
VDD1A
27
CBYPASS
Magnetics
RJ45
TXP
29
1
2
3
4
5
6
7
8
75
TXN
RXP
28
31
75
RXN
30
CBYPASS
1000 pF
3 kV
Figure 8.4 Copper Interface Diagram
Revision 1.0 (04-15-09)
74
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
8.2
Magnetics Selection
For a list of magnetics selected to operate with the SMSC LAN8710, please refer to the Application
note “AN 8-13 Suggested Magnetics”.
http://www.smsc.com/main/appnotes.html#Ethernet%20Products
SMSC LAN8710/LAN8710i
75
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Chapter 9 Package Outline
Figure 9.1 LAN8710/LAN8710i-EZK 32 Pin QFN Package Outline, 5 x 5 x 0.9 mm Body (Lead-Free)
Table 9.1 32 Terminal QFN Package Parameters
A
A1
A2
A3
D
D1
D2
E
E1
E2
L
e
b
ccc
Notes:
MIN
0.70
0
~
4.85
4.55
3.15
4.85
4.55
3.15
0.30
0.18
~
NOMINAL
~
0.02
~
0.20 REF
5.0
~
3.3
5.0
~
3.3
~
0.50 BSC
0.25
~
MAX
1.00
0.05
0.90
5.15
4.95
3.45
5.15
4.95
3.45
0.50
0.30
0.08
REMARKS
Overall Package Height
Standoff
Mold Thickness
Copper Lead-frame Substrate
X Overall Size
X Mold Cap Size
X exposed Pad Size
Y Overall Size
Y Mold Cap Size
Y exposed Pad Size
Terminal Length
Terminal Pitch
Terminal Width
Coplanarity
1. Controlling Unit: millimeter.
2. Dimension b applies to plated terminals and is measured between 0.15mm and 0.30mm from the
terminal tip. Tolerance on the true position of the leads is ± 0.05 mm at maximum material
conditions (MMC).
3. Details of terminal #1 identifier are optional but must be located within the zone indicated.
4. Coplanarity zone applies to exposed pad and terminals.
Revision 1.0 (04-15-09)
76
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Figure 9.1 QFN, 5x5 Taping Dimensions and Part Orientation
SMSC LAN8710/LAN8710i
77
DATASHEET
Revision 1.0 (04-15-09)
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Figure 9.2 Reel Dimensions for 12mm Carrier Tape
Revision 1.0 (04-15-09)
78
DATASHEET
SMSC LAN8710/LAN8710i
MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint
Datasheet
Figure 9.3 Tape Length and Part Quantity
Note: Standard reel size is 4000 pieces per reel.
SMSC LAN8710/LAN8710i
79
DATASHEET
Revision 1.0 (04-15-09)