Mar. 16, 2007 2x5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G) FTM-9412S-F20FD(G) (IEEE 802.3ah™-2004 1000BASE-PX20-U) Members of FlexonTM Family Standard Compliant with SFF MSA Compliant with IEEE Std 802.3ah™ -2004 1000BASE-PX20-U Compliant with FCC 47 CFR Part 15, Class B Compliant with FDA 21 CFR 1040.10 and 1040.11, Class I Features Description Single fiber bi-directional data links with symmetric FTM-9412S-F20F(G)/F20FD(G) is Optical Network Unit 1.25Gbps upstream and 1.25Gbps downstream (ONU) for IEEE802.3ah™-2004 1000BASE-PX20-U Integrated with micro-optics WDM filter for dual application. wavelength Tx/Rx operation at 1310/1490nm The transceiver is the high performance module for 1310nm burst-mode transmitter with FP laser 1490nm continuous-mode receiver with PIN-TIA 1550nm optical signal rejection 0 to 70℃ operating case temperature 2× 5 SFF package with SC receptacle form The transmitter section uses a multiple quantum well Single 3.3V power supply 1310nm FP laser and is ClassⅠlaser compliant product LVPECL compatible data input/output interface according to international safety standard IEC-60825. LVTTL transmitter burst-mode control LVTTL receiver signal-detected indication Low EMI and excellent ESD protection Class I laser safety standard IEC-60825 compliant 1.25Gbps data link in single fiber by using 1310nm burst-mode transmitter and 1490nm continuous-mode receiver with 1550nm optical signal rejection. The receiver section uses an integrated 1490nm PIN and preamplifier mounted in an optical header and limiting post-amplifier IC. The optical burst output can be enabled by a LVTTL logic high-level input of TX_BRST. Signal Detected (SD) Applications output is provided to indicate the detection of an input optical signal of receiver. Gigabit Ethernet Passive Optical Networks (GEPON) – ONU side Gigabit Ethernet Point-to-Point Bi-directional Transmission Media Converts for Fiber-In-The-Loop (FITL) Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 1 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Regulatory Compliance The transceivers have been tested according to American and European product safety and electromagnetic compatibility regulations (See Table 1). For further information regarding regulatory certification, please refer to FlexonTM regulatory specification and safety guidelines, or contact with Fiberxon, Inc. America sales office listed at the end of documentation. Table 1 - Regulatory Compliance Feature Standard Electrostatic Discharge MIL-STD-883E (ESD) to the Electrical Pins Method 3015.7 Performance Class Ⅰ(>500 V) FCC Part 15 Class B Electromagnetic EN55022 Class B (CISPR 22B) Interference (EMI) Compliant with standards VCCI Class B Immunity IEC 61000-4-3 Compliant with standards FDA 21CFR 1040.10 and 1040.11 Laser Eye Safety Compliant with Class I laser product EN60950, EN (IEC) 60825-1,2 Component Recognition UL and CSA Compliant with standards Absolute Maximum Ratings Absolute Maximum Ratings are those values, beyond which, some damages may occur to the devices. Exposure to conditions above the Absolute Maximum Ratings listed in Table 2 may negatively impact the reliability of the products. Table 2 - Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Ambient Temperature TSTG -40 85 °C Operating Case Temperature TC 0 70 °C Operating Humidity HOPR 5 95 % Power Supply Voltage VCC 0 4 V GND Vcc V Input Voltage Receiver Damaged Threshold +7 Soldering Temperature Note dBm 260/10 °C/s 1 400 °C 2 Note 1: Soldering on lead only, for FTM-9412S-F20FG and FTM-9412S-F20FDG Note 2: Only for soldering by iron and 10 seconds on leads only, for FTM-9412S-F20F and FTM-9412S-F20FD Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 2 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Recommended Operating Conditions Table 3 - Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Unit Note Power Supply Voltage VCC 3.13 3.3 3.47 V 3.3V±5% Operating Case Temperature TC 0 70 °C HOPR 5 95 % Operating Humidity Range Data Rate 1.25 Data Rate Drift -100 Gbit/s +100 PPM Optical and Electrical Characteristics Table 4 - Transmitter Optical and Electrical Characteristics (0°C <TC<70°C and 3.13V<VCC<3.47V) Parameter Symbol Min. Optical Center Wavelength λC 1276 Optical Spectrum Width (RMS) ∆λ Average Launch Power POUT Average Launch Power-OFF Transmitter POFF Typ. Max. Unit 1356 nm 2.8 nm +4 dBm -45 dBm 0 Extinction Ratio ER Total Jitter TJ 0.35 UI TR/TF 260 ps Burst Turn On Time TBURST_ON 30 ns Burst Turn Off Time TBURST_OFF Rise/Fall Time (20%-80%) 9 dB 30 ns Burst Enable Duration TEN_DUR 600 ns Burst Disable Duration TDIS_DUR 100 ns RIN15OMA -115 dB/Hz Optical Return Loss Tolerance 15 dB Transmitter Reflectance -10 dB Optical Eye Diagram Compliant With IEEE Std 802.3ah™-2004 Data Input Differential Swing VIN 200 Common-Mode Input Voltage VCM VCC-1.49 Input Differential Impedance ZIN 90 Note 1 2 2.3 4 2,5 1600 mV 6 VCC-1.32 VCC- VIN/4 V 7 100 110 Ω Power Supply Current ICC_TX 200 mA Transmitter Burst Control Voltage - Low VTDIS, L 0 0.8 V Transmitter Burst Control Voltage -High VTDIS, H 2.0 VCC V 8 Note 1: Launched into 9/125um Single Mode Fiber. Note 2: Measured with PRBS 27-1 test pattern @1.25 Gbit/s. Note 3: Measured with the Bessel-Thompson filter OFF. Note 4: Refer to Timing Parameter Definition in Burst Mode Sequence. Note 5: Transmitter eye mask definition is {0.22UI, 0.375UI, 0.20UI, 0.20UI, 0.30UI}. Note 6: Compatible with LVPECL/CML input, AC coupled internally. (See Recommended Interface Circuit) Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 3 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Note 7: Only for FTM-9412S-F20FD(G) Note 8: TX_BRST (See Pin Function Definitions) Table 5 - Receiver Optical and Electrical Characteristics (0°C <TC<70°C and 3.13V<VCC<3.47V) Parameter Symbol Min. Operating Wavelength 1480 Sensitivity PSEN Saturation PSAT Signal-Detected Assert Level PSDA Signal-Detected Deassert Level PSDD -39 PSDA- PSDD 0.5 Signal-Detected Hysteresis Max. Unit 1500 nm -26.5 dBm -3 dBm -27 Receiver Reflectance WDM Filter Isolation Typical 1 dBm 2 dBm 3 6 dBm -12 dB ISO(1550) 38 dB 1550nm ISO(1650) 35 dB 1650nm Power Supply Current ICC_RX 120 mA Data Output Differential Swing VOUT 400 1600 mV Signal-Detected Voltage - Low VSD, L 0 0.8 V Signal-Detected Voltage - High VSD, H 2.0 VCC V Signal-Detected Assert Time TASS 100 µs TDAS 100 Signal-Detected Deassert Time Notes 7 4 5 µs -12 Note 1: Measured with a PRBS 2 -1 test pattern @1.25Gbit/s and ER=9dB, BER =10 . Note 2: An increase in optical power above the specified level will cause the Signal Detect output to switch from a low state to a high state. Note 3: A decrease in optical power below the specified level will cause the Signal Detect output to switch from a high state to a low state. Note 4: LVPECL output, AC coupled internally, guaranteed in the full range of input optical power (-3dBm to -27dBm) (See Recommended Interface Circuit) Note 5: SD (See Pin Function Definitions) Table 6 - Electrical Input/Output Coupling Mode Input (TD+/TD-) Output (RD+/RD-) FTM-9412S-F20F(G) P/N Internal AC Coupling Internal AC Coupling FTM-9412S-F20FD(G) Internal DC Coupling Internal AC Coupling Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 4 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet TX_BRST Mar. 16, 2007 T DIS_DUR T EN _DU R TD+ TD- Average Power <=-45dBm Optical Power Output ER for CM operation T BUR ST_ON ER and Average Power within 15% CM operation T BUR ST_OFF Burst Off Condition Burst On Condition Figure 1 Timing Parameter Definition in Burst Mode Sequence Recommended Interface Circuit Figure 2 shows the recommended interface schemes for FTM-9412S-F20F(G) Figure 2 Recommended Interface Circuit (FTM-9412S-F20F(G)) Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 5 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Note A: Open emitter output internally. Note B: LVPECL output, AC coupled internally. Input stage in SerDes IC is assumed with high impedance and internal bias to Vcc-1.3V R1=R2=R3=R4=N.C, R5=100Ω Input stage in SerDes IC is assumed without internal bias to Vcc-1.3V R1=R2=82Ω,R3=R4=130Ω,R5=N.C Figure 3 shows the recommended interface schemes for FTM-9412S-F20FD(G) Figure 3 Recommended Interface Circuit (FTM-9412S-F20FD(G)) Note A: Open emitter output internally. Note B: LVPECL output, AC coupled internally. Input stage in SerDes IC is assumed with high impedance and internal bias to Vcc-1.3V R1=R2=R3=R4=N.C, R5=100Ω Input stage in SerDes IC is assumed without internal bias to Vcc-1.3V R1=R2=82Ω,R3=R4=130Ω,R5=N.C Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 6 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Pin Definitions 2×5 SFF planform in Figure 4 below shows the pin information of electrical interface and mounting studs. Functions are described in Table 7 with some accompanying notes. Figure 4 2×5 SFF Planform Table 7 - Pin Function Definitions Pin No. Name Description Notes 1 VEER Receiver Signal Ground 2 VCCR Receiver Power Supply 3 SD Receiver Signal-Detected Indication 4 RD- Inverted Receiver Data Output 5 RD+ Non-inverted Receiver Data Output 6 VCCT Transmitter Power Supply 7 VEET Transmitter Signal Ground 8 TX_BRST Transmitter Burst Control 9 TD+ Transmitter Non-inverted Data Input 10 TD- Transmitter Inverted Data Input MS MS Mounting Studs 5 HL HL Housing Leads 6 1 2 3 4 Note 1: TTL logic output, with internal 10KΩ pull-up resistor. Optical Signal-Detected: High; Optical Signal Loss: Low Note 2: LVPECL logic output, AC coupled internally. (See Recommended Interface Circuit) Note 3: A positive level enable optical signal output under burst mode. (See Timing Parameter Definition in Burst Mode Sequence) Note 4: Note 4: Compatible with LVPEC input (See Recommended Interface Circuit and Table 6 - Electrical Input/Output Coupling Mode) Note 5: The mounting studs are provided for transceiver mechanical attachment to circuit board. They may also provide an optional connection of the transceiver to the equipment chassis ground. The holes in the circuit board must be tied to chassis ground. Note 6: The housing leads may be provided for additional signal grounding. These additional grounds may improve signal integrity, EMC, or ESD performance. The holes in the circuit board must be included and be tied to signal ground. Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 7 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Mechanical Design Diagram The form factor is 2×5 SFF. The mechanical design diagram is shown in Figure 5. (Dimension in mm) Figure 5 Mechanical Design Diagram Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 8 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Ordering Information Part No. FTM-9412S-F20F FTM-9412S-F20FD FTM-9412S-F20FG FTM-9412S-F20FDG Product Description 1310nm(TX)/1490nm(RX), SC/UPC receptacle 2×5 SFF for GEPON ONU 20km (PX20) application, 0°C ~ 70°C(case temperature), Tx AC Coupling, Rx AC Coupling 1310nm(TX)/1490nm(RX), SC/UPC receptacle 2×5 SFF for GEPON ONU 20km (PX20) application, 0°C ~ 70°C(case temperature), Tx DC Coupling, Rx AC Coupling 1310nm(TX)/1490nm(RX), SC/UPC receptacle 2×5 SFF for GEPON ONU 20km (PX20) application, 0°C~70°C(case temperature), Tx AC Coupling, Rx AC Coupling, RoHS compliance 1310nm(TX)/1490nm(RX), SC/UPC receptacle 2×5 SFF for GEPON ONU 20km (PX20) application, 0°C~70°C(case temperature), Tx DC Coupling, Rx AC Coupling, RoHS compliance Related Documents For further information, please refer to the following documents: IEEE Std 802.3ahTM-2004 Obtaining Document You can visit our website: http://www.fiberxon.com/ Or contact with Fiberxon, Inc. America Sales Office listed at the end of documentation to get the latest documents. Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 9 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 Revision History Reversion Initiate Review Approve Subject Release Date Pre 1a Johnny Yang Peter Tang Peter Tang Initial datasheet (Doc No. DS3493013-1a) 2006-04-06 Revised datasheet Pre 1b Jacob Cai Johnny Yang Peter Tang Change the product picture 2006-06-30 (Doc No. DS3493013-1b) Revised datasheet Pre 1c Jacob Cai Johnny Yang Peter Tang Change the Mechanical Design Diagram in Figure 5 2006-08-09 (Doc No. DS3493013-1c) Revised datasheet Pre 1d Jacob Cai Johnny Yang Peter Tang 1. Change Mechanical Design Diagram in Figure 5; 2006-11-10 (Doc No. DS3493013-1d) Revised datasheet 1. Change the photo in cover page; Pre 1e Jacob Cai Johnny Yang Peter Tang 2. Change Figure 4; 2007-1-19 3. Update Table 7 and its notes. (Doc No. DS3493013-1e) Revised datasheet 1. Update “Product Description” in “Ordering Information” section. Pre 1f Jacob Cai Johnny Yang Peter Tang 2007-3-16 2. Update Figure 5; 3. Update “Average Launch Power” item in Table 4; (Doc No. DS3493013-1f) Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 10 of 11 Doc No: DS3493013-1f 2×5 SFF GEPON ONU Diplexer FTM-9412S-F20F(G)/ FTM-9412S-F20FD(G) IEEE 802.3ahTM 1000BASE-PX20U Preliminary Data Sheet Mar. 16, 2007 © Copyright Fiberxon Inc. 2007 All Rights Reserved. All information contained in this document is subject to change without notice. The products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Fiberxon’s product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Fiberxon or third parties. All information contained in this document was obtained in specific environments, and is presented as an illustration. The results obtained in other operating environment may vary. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN ”AS IS” BASIS. In no event will Fiberxon be liable for damages arising directly from any use of the information contained in this document. Contact U.S.A. Headquarter: 5201 Great America Parkway, Suite 340 Santa Clara, CA 95054 U. S. A. Tel: 408-562-6288 Fax: 408-562-6289 Or visit our website: http://www.fiberxon.com/ Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 11 of 11 Doc No: DS3493013-1f