SOURCE FTM-C001R-LG

July 24, 2007
100BASE-T Copper SFP Transceiver
(For 100m reach over Cat 5 UTP cable)
Members of FlexonTM Family
Standard
‹
Compliant with SFP MSA
‹
Compliant with IEEE Std 802.3TM-2002
Compliant with FCC 47 CFR Part 15, Class B
RoHS compliance and lead free assembly
process compatibility
‹
‹
Description
Fiberxon FTM-C001R-LG 100BASE-T copper SFP
transceiver is high performance, cost effective
Features
module compliant with the 100BASE-T standards as
‹
100Mbps bi-direction data links
specified in IEEE 802.3-2002 and IEEE 802.3ab,
‹
100m transmission over unshielded twisted-
which supporting 100Mbps up to 100 meters reach
pair (UTP) Category 5 Cable
over unshielded twisted-pair category-5 cable.
‹
Perform
any
necessary
scrambling
/
descrambling between the 100Base-TX and
FTM-C001R-LG is a “Hot-Pluggable” 100Base-TX
Ethernet electrical interface SFP module.
100Base-FX formats.
‹
Support intelligent auto-negotiation 100BASE-T
operation in host systems
The FTM-C001R-LG provides standard serial ID
‹
Hot-pluggable capability
information compliant with SFP MSA, which can be
‹
SFP form with compact RJ-45 connector
accessed with address of A0h via the two-wire serial
‹
With spring latch for high density application
CMOS EEPROM protocol.
‹
Very low EMI and excellent ESD protection
‹
+3.3V single power supply
‹
Low power dissipation
‹
‹
Operating case temperature: 0 to +70°C
The FTM-C001R-LG is RoHS compatible.
Detailed product information in EEPROM
Applications
‹
LAN 100Base-T
‹
Switch to Switch interface
‹
Switched backplane applications
‹
Router/Server interface
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 1 of 8
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
Preliminary Data Sheet
July 24, 2007
Regulatory Compliance
The transceivers have been tested according to American and European product safety and electromagnetic
compatibility regulations (See Table 1). For further information regarding regulatory certification, please refer
to Fiberxon regulatory specification and safety guidelines, or contact with Fiberxon, Inc. America sales office
listed at the end of the documentation.
Table 1 - Regulatory Compliance
Feature
Standard
Electrostatic Discharge
MIL-STD-883E
(ESD) to the Electrical Pins
Method 3015.7
Electrostatic Discharge (ESD)
IEC 61000-4-2
to the RJ-45 Receptacle
GR-1089-CORE
Performance
Class 2(>2000 V)
Compatible with standards
FCC Part 15 Class B
Electromagnetic
EN55022 Class B (CISPR 22B)
Interference (EMI)
Compatible with standards
VCCI Class B
Immunity
IEC 61000-4-3
Compatible with standards
Component Recognition
UL and CSA
Compatible with standards
Absolute Maximum Ratings
Stress in excess of the maximum absolute ratings can cause permanent damage to the module.
Table 2 - Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Unit
Storage Temperature
TS
0
+70
°C
Supply Voltage
VCC
-0.5
3.6
V
-
5
95
%
Operating Relative Humidity
Recommended Operating Conditions
Table 3- Recommended Operating Conditions
Parameter
Symbol
Min.
Operating Case Temperature
TC
0
Power Supply Voltage
VCC
3.13
Power Supply Current
ICC
Data Rate
Typical
Max.
Unit
+70
°C
3.30
3.47
V
170
300
mA
100
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 2 of 8
Mbps
Notes
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
Preliminary Data Sheet
July 24, 2007
Host Side Electrical Interface
Table 4 - Electrical Characteristics
Parameter
Symbol
Min.
Data Input Swing Differential
VIN
500
Input Differential Impedance
ZIN
Data Output Swing Differential
VOUT
Output Differential Impedance
ZOUT
Output Data Rise/Fall Time
Tr/Tf
Typical
Max.
Unit
Notes
2400
mV
1
100
Ω
370
2000
mV
100
2
Ω
3
ns
Max.
Unit
Notes:
1.
Internally AC coupled and terminated.
2.
Internally AC coupled.
Line Side Electrical Interface
Table 5 - Electrical Characteristics
Parameter
Symbol
Min.
Line Baud Rate
Typical
125
Bit Error Rate
Notes
MBaud
-12
BER
10
1
Line Rx Intput Impedance
ZIN
100
Ω
Line Tx Output Impedance
ZOUT
100
Ω
Notes:
1.
Measured over 100m Cat-5 UTP cable.
EEPROM Information
The SFP MSA defines a 256-byte memory map in EEPROM describing the transceiver’s capabilities,
standard interfaces, manufacturer, and other information, which is accessible over a 2 wire serial interface at
the 8-bit address 1010000X (A0h). The memory contents refer to Table 6.
Table 6 - EEPROM Serial ID Memory Contents (A0h)
Addr.
Field Size
(Bytes)
Name of Field
Hex
Description
0
1
Identifier
03
SFP
1
1
Ext. Identifier
04
MOD4
2
1
Connector
00
3—10
8
Transceiver
00 00 00 30 00 00 00 00
11
1
Encoding
02
4B5B
12
1
BR, nominal
01
100M
13
1
Reserved
00
14
1
Length (9um)-km 00
15
1
Length (9um) 00
100BASE-FX/100BASE-LX
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 3 of 8
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
16
1
Length (50um) 00
17
1
Length (62.5um) 00
18
1
Length (copper) 64
19
1
Reserved
20—35
16
Vendor name
36
1
Reserved
37—39
3
Vendor OUI
40—55
16
Vendor PN
56—59
4
Vendor rev
xx xx xx xx
60-61
2
Wavelength
00 00
62
1
Reserved
00
63
1
CC BASE
xx
64—65
2
Options
00 00
66
1
BR, max
00
67
1
BR, min
00
68—83
16
Vendor SN
84—91
8
92—94
3
Reserved
95
1
CC EXT
96—255
160
Vendor specific
Preliminary Data Sheet
July 24, 2007
100m
00
46 49 42 45 52 58 4F 4E
“FIBERXON INC. “(ASCⅡ)
20 49 4E 43 2E 20 20 20
00
00 00 00
46 54 4D 2D 43 30 30 31
“FTM-C001R-LG ” (ASCⅡ)
52 2D 4C 47 20 20 20 20
ASCⅡ (“31 30 20 20” means 1.0 revision)
Check sum of bytes 0 - 62
xx xx xx xx xx xx xx xx
ASCⅡ
xx xx xx xx xx xx xx xx
Vendor date codexx xx xx xx xx xx 20 20
Year (2 bytes), Month (2 bytes), Day (2 bytes)
00 00 00
xx
Check sum of bytes 64 - 94
Note: The “xx” byte should be filled in according to practical case. For more information, please refer to the
related document of SFP MSA.
Recommended Host Board Power Supply Circuit
Figure 1 shows the recommended host board power supply circuit.
Figure 1, Recommended Host Board Power Supply Circuit
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 4 of 8
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
Preliminary Data Sheet
July 24, 2007
20-Pin Definitions
Figure 2 below shows the 20-pin numbering of SFP to Host electrical interface. The pin functions are
described in Table 7 with some accompanying notes.
P in 2 0
T O P V IE W
OF BOARD
P in 1 1
P in 1 0
B O T T O M V IE W
OF BOARD
P in 1
Figure 2, Pin View
Table 7– Pin Function Definitions
Pin No.
Name
1
VeeT
2
TX Fault
3
Function
Plug Seq.
Notes
Transmitter Ground
1
Transmitter Fault Indication
3
Note 1
TX Disable
Transmitter Disable
3
Note 2
4
MOD-DEF2
Module Definition 2
3
Note 3
5
MOD-DEF1
Module Definition 1
3
Note 3
6
MOD-DEF0
Module Definition 0
3
Note 3
7
Rate Select
Not Connected
3
8
LOS
Loss of Signal
3
9
VeeR
Receiver Ground
1
10
VeeR
Receiver Ground
1
11
VeeR
Receiver Ground
1
12
RD-
Inv. Received Data Out
3
Note 5
13
RD+
Received Data Out
3
Note 5
14
VeeR
Receiver Ground
1
15
VccR
Receiver Power
2
16
VccT
Transmitter Power
2
17
VeeT
Transmitter Ground
1
18
TD+
Transmit Data In
3
Note 6
19
TD-
Inv. Transmit Data In
3
Note 6
20
VeeT
Transmitter Ground
1
Note 4
Notes:
1. TX Fault is not used and tied to ground within the module.
2. TX Disable is not used and is not connected within the module.
3. MOD-DEF 0,1,2 are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 5 of 8
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
Preliminary Data Sheet
July 24, 2007
the host board. The pull-up voltage shall be VccT or VccR.
MOD-DEF 0 is tied to ground within the module.
MOD-DEF 1 is the clock line of two wire serial interface for serial ID
MOD-DEF 2 is the data line of two wire serial interface for serial ID
4. LOS is not used and tied to ground within the module.
5. These are the differential receiver output. They are internally AC-coupled 100Ω differential lines which
should be terminated with 100Ω (differential) at the user SERDES.
6. These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential
termination inside the module.
Mechanical Design Diagram
The mechanical design diagram is shown in Figure 3.
Figure 3, Mechanical Design Diagram
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 6 of 8
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
Preliminary Data Sheet
July 24, 2007
Ordering information
Part No.
FTM-C001R-LG
Product Description
100Mbps, 100base-TX convert to 100base-FX, Copper SFP with spring latch, 0°C~+70°C,
ROHS compliance
Related Documents
For further information, please refer to the following documents:
■
Fiberxon SFP Application Notes
■
Fiberxon 100BASE-T Copper SFP Application Note
■
SFP Multi-Source Agreement (MSA)
Obtaining Document
You can visit our website:
http://www.fiberxon.com
Or contact with Fiberxon, Inc. America Sales Office listed at the end of documentation to get the latest
documents.
Revision History
Revision
Rev. 1a
Initiate
Review
Approve
Unvier.Yang
Armstrong.tian
Tripper.huang
Subject
Initial datasheet
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 7 of 8
Release Date
July 24, 2007
100BASE-T Copper SFP Transceiver
100m transmission over Cat-5 UTP cable
Preliminary Data Sheet
July 24, 2007
© Copyright Fiberxon Inc. 2007
All Rights Reserved.
All information contained in this document is subject to change without notice. The products described in this
document are NOT intended for use in implantation or other life support applications where malfunction may
result in injury or death to persons.
The information contained in this document does not affect or change Fiberxon product specifications or
warranties. Nothing in this document shall operate as an express or implied license or indemnity under the
intellectual property rights of Fiberxon or third parties. All information contained in this document was obtained
in specific environments, and is presented as an illustration. The results obtained in other operating
environment may vary.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN ”AS IS” BASIS. In no event
will Fiberxon be liable for damages arising directly from any use of the information contained in this document.
Contact
U.S.A. Headquarter:
5201 Great America Parkway, Suite 340
Santa Clara, CA 95054
U. S. A.
Tel: 408-562-6288
Fax: 408-562-6289
Or visit our website: http://www.fiberxon.com
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 8 of 8