345.00 MHz SAW Filter • Designed to Provide Front-end Selectivity in 345.00 MHz • Low-Loss, Coupled-Resonator Quartz Design • Simple External Impedance Matching • Ultra Miniature Ceramic QCC8C SMD Package SF5402 Absolute Maximum Rating (Ta=25°C) Rating Unit Source Power Parameter PS 0 dBm DC Voltage VDC Between Any Two Pins VDC 0 V Operating Temperature Range TA -10 ~ +60 °C Storage Temperature Range Tstg -40 ~ +85 °C Electronic Characteristics Parameter Nominal Frequency (at 25°C) (Center frequency between 3dB point) Sym Minimum Typical Maximum Unit fC NS 345.00 NS MHz Insertion Loss 344.60 … 345.60 MHz IL - 2.5 4.0 dB Amplitude Ripple (p-p) 344.60 … 345.60 MHz ∆α - 0.5 1.5 MHz 10.00 … 320.00 MHz 48 53 - dB 320.00 … 325.00 MHz 41 47 - dB 325.00 … 337.00 MHz 32 39 - dB dB Relative Attenuation (relative to IL) Frequency Aging αrel 26 31 - dB 351.00 … 358.00 MHz 13 16 - dB 358.00 … 370.00 MHz 35 39 - dB 370.00 … 700.00 MHz 47 52 - dB 700.00 … 1000.00 MHz 40 45 - dB 337.00 … 339.00 MHz |fA| - - 10 ppm/yr DC Insulation Resistance Between any Two Pins Absolute Value during the First Year - 1.0 - - MΩ Input / Output Impedance - - 50 - Ω NS = Not Specified Notes: 1. The frequency fC is defined as the midpoint between the 3dB frequencies. 2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is connected to a 50Ω test system with VSWR ≤ 1.2:1. The test fixture L and C are adjusted for minimum insertion loss at the filter center frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on the impedance matching component values and quality. 5. Turnover temperature, T0, is the temperature of maximum (or turnover) frequency, f0. The nominal frequency at any case temperature, TC, may be calculated from: f = f0 [1 - FTC (T0 - TC)2]. 6. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence without notice. 7. All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale. 3. Unless noted otherwise, specifications apply over the entire specified operating temperature range. 8. 4. Frequency aging is the change in fC with time and is specified at +65°C or less. Aging may exceed the specification for prolonged temperatures above +65°C. Typically, aging is greatest the first year after manufacture, decreasing in subsequent years. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications, processes and circuits implemented within components or assemblies. 9. For questions on technology, prices and delivery please contact our sales offices or e-mail [email protected]. Phone: +86 10 6301 4184 Fax: +86 10 6301 9167 © April 2004 by Vanlong Technology Co., Ltd. Email: [email protected] Web: http://www.vanlong.com SF5402 345.00 MHz SAW Filter Package Dimensions (QCC8C) Electrical Connections Terminals 2 1,3 6 5,7 4,8 Connection Input Input Ground Output Output Ground Case Ground Package Dimensions Dimensions A B C D Marking Nom (mm) 2.08 0.60 1.27 2.54 Dimensions E F G H Nom (mm) 1.20 1.35 5.00 5.00 Test Circuit 1. F5402 - Part Code F5402 345.0 YWW 2. Frequency (MHz) in 5 digits 3. Date Code: Y : Last digit of year WW : Week No. No matching network required for operation at 50Ω Typical Frequency Response Phone: +86 10 6301 4184 Fax: +86 10 6301 9167 © April 2004 by Vanlong Technology Co., Ltd. Email: [email protected] Web: http://www.vanlong.com SF5402