XPPOWER GP05UD12

Universal AC Input Switchers
5-10 Watts
THE XPERTS IN POWER
GP Series
•
85-264 VAC Input
•
Single & Dual Ouptuts
•
PCB Mounting
•
Eurocard Mounting Option
•
DIN Rail Mounting Option
•
Chassis Mounting Option
•
International Safety Approvals
Specification
Input
Environmental
Input Voltage
Input Frequency
Inrush Current
•
•
•
85-264 VAC (110-370 VDC)
47-440 Hz
20 A typical at 100 VAC,
40 A typical at 200 VAC,
(cold start & full load)
Operating
Temperature
•
Humidity
Shock
•
•
•
•
•
•
•
•
10 ms at 85 VAC full load
See Table, ±5% initial tolerance
See Table
See Table
See Table
Operates >105% of rating &
recovers automatically
Vibration
•
•
0.02%/°C typical
•
•
•
250 kHz
See Table
3000 VAC 1 min, 500 VDC 50 Mohm
Input to Output,
2000 VAC 1 min, 500 VDC 50 Mohm
Input to Case, FG
500 VAC 1 min, 500 VDC 50 Mohm
Output to Case, FG
Output
Hold Up Time
Output Voltage
Line Regulation
Load Regulation
Ripple & Noise
Short Circuit &
Overload Protection
General
Temperature
Coefficient
Switching Frequency
Efficiency
Isolation
0 °C to +55 °C,
derate linearly to 80% at -10 °C to
25% at +70 °C for 85-132 VAC,
& 45% at +65 °C for 133-264 VAC
20-95% RH non-condensing
50 G for 11 ms, once on each
X, Y & Z axis
10-55 Hz at 10 G, 3 mins period
60 mins each along each along
X, Y & Z axis
EMC & Safety
Safety Approvals
•
EMC
•
IEC950, EN60950, UL1950, VDE 0160,
CSA 22.2 No.234
N.B. To comply with with CSA agency
approval units are labelled with
nominal AC input voltage & frequency
FCC Curve B, VDE 0871 Curve B, &
EN55022B conducted noise with
addition of 0.1 µF ‘X’ capacitor fitted
across AC input
•
•
www.xpplc.com
[email protected]
Output
Voltage
5V
12 V
+12 V (24 V)
+15 V (30 V)
5V
12 V
+12 V (24 V)
+15 V (30 V)
Output
Current
1.00 A
0.45 A
0.22 A
0.17 A
2.00 A
0.90 A
0.45 A
0.35 A
Efficiency
(Typical @ 100 VAC)
65%
67%
67%
67%
70%
72%
72%
72%
GP
Regulation
Line(1)
Load(2)
20 mV
40 mV
40 mV
100 mV
60 mV
600 mV
75 mV
750 mV
20 mV
40 mV
48 mV
100 mV
60 mV
600 mV
75 mV
750 mV
Ripple & Noise
Pk-Pk
80/120 mV
120/150 mV
120/150 mV
120/150 mV
80/120 mV
120/150 mV
120/150 mV
120/150 mV
Model
Number
GP05US05
GP05US12
GP05UD12
GP05UD15
GP10US05
GP10US12
GP10UD12
GP10UD15
AC-DC Power Supplies
OUTPUT VOLTAGE & CURRENT RATINGS
Notes
Mechanical Details
5 W Models
10 W Models
Weight: 75g max
Dimension: Inches (mm)
Tolerance: ±0.5 mm
(1)
Tolerance :±0.3 mm
Weight: 100g max
Dimension: Inches (mm)
Tolerance: ±0.5 mm
(1)
Tolerance :±0.3 mm
Universal AC Input Switchers 5-10 Watts GP Series
•
1. Measured low line to high line.
2. Measured no load to full load.
Mounting Options
The GP-BOARD is designed to accept any of the GP series models, in addition it can be supplied with a DIN HOUSING for mounting on
DIN rails - both top hat and G types. Order GP-BOARD(S) for single output models and GP-BOARD(D) for dual output models.
2.64 (67.0)
3.66 (93.0)
4 x 0.16 (4.0) holes, 3.35 (85.0) x 2.36 (60.0)
The GP-EUROCARD (3.94 (100) x 6.31 (160) is designed to accept any combination of two GP series models to provide dual, triple and
quad outputs. In addition it can be supplied with a GP-E/CARD KIT which includes 6TE front panel and plastic cover for rear of pcb.
www.xpplc.com
[email protected]
Rev 2.0