XPPOWER M5S4S4ME5

AC-DC
250-450 Watts
xppower.com
LP & LP-MD Series
•
Configurable for Fast Time to Market
•
Industrial/IT & Medical Approvals
•
All Outputs Isolated
•
Low Profile 1U Applications
•
Wide Voltage Adjustment Range
•
SEMI F47 Certified
•
Rugged Compact Design
Specification
Input
Input Voltage
Input Frequency
Inrush Current
Power Factor
General
•
•
•
•
90-264 VAC
47-63 Hz
20 A pk max
Compliant with EN61000-3-2
Efficiency
Isolation
Signals & Controls
Output
Output Voltage
Output Voltage Trim
• See module table
• ±10 % min all modules. See module table
for extended adjustment range
Hold Up Time
• 20 ms min
Line Regulation
• Typically 0.1%, maximum 0.3%
Load Regulation
• 1% max for single output modules & V1 of
dual & triple output modules
2% max for V2 & V3 of dual & triple output
modules
A 10% load must be applied to output 1 of
the high current dual module (U) & triple
module (T) to achieve this figure
Ripple & Noise
• 50 mV or 1% pk-pk, whichever is greater,
20 MHz bandwidth
Overvoltage Protection • 120-130% Vnom for single output &
output 1 of high current dual modules (U)
& triple modules (T)
Overload Protection
• <140% of nominal rating
Short Circuit Protection • Foldback
Temperature
• 0.03%/°C
Coefficient
Remote Sense
• Compensates for up to 0.5 V drop on
single (S) output modules & output 1
of dual (U) & triple (T) output modules
Current Share
• Single wire parallel current share. See
signals & controls page
MTBF
• 75% typical at nominal input
• 4000 VAC Input to Output
1500 VAC Input to Ground
50 VAC Output to Ground
• AC OK, DC OK, Global & Module Inhibit.
See signals & controls page
• 890 kHrs demonstrated
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
at +50 °C to 50% at +70 °C for fan
versions. See airflow curves for U-channel
versions.
Storage Temperature
• -40 °C to +85 °C
Operating Altitude
• 3000 m with no derating
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• LP models P3-P5:
EN55022, level B conducted
LP-MD models, M3-M5:
EN55011,
level A conducted with FE(x) cover,
level B conducted with ME(x) cover
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Criteria A, B, B
• LP models: EN60950, UL60950, CSA22.2
No 950, CE Mark LVD, SEMI F47
compliant (highline only)
LP-MD models: EN60601-1, CSA22.2-601,
UL60601-1, CE Mark LVD
STEP 1
In order to configure a model number for your LP (industrial) or LP-MD (medical) series power supply, first select
the appropriate chassis based on your application’s continuous, maximum output power requirements. Select ‘P’
for industrial or ‘M’ for medical.
STEP 2
From the ratings below, select the output modules that suit your output voltage and current requirements. Modules
can be positioned as denoted by the
and
sequence shown below.
STEP 3
Form the model number as shown on the next page, ensuring you have selected a cooling method.
P3 & M3 (250 W) Model
Module Position
2
1
P5 & M5 (450 W) Model
Module Position
2
1
P4 & M4 (350 W) Model
Module Position
2
1
None
None
None
None
None
None
Output Modules Voltage (Adjustment) & Current Ratings
OUTPUT 1
1.8
2.5
3.3
5.0
8.0
10.0
12.0
15.0
24.0
28.0
36.0
48.0
3.3
3.3
3.3
3.3
5.0
5.0
5.0
5.0
5.0
5.0
12.0
12.0
15.0
3.3
3.3
5.0
5.0
5.0
12.0
12.0
24.0
24.0
24.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
(1.65-1.95
(2.25-2.75
(3.25-3.50
(4.50-5.50
(7.20-8.80
(9.00-11.00
(11.00-13.00
(14.00-16.00
(21.00-26.00
(25.00-31.00
(32.00-40.00
(43.00-53.00
(3.25-3.50
(3.25-3.50
(3.25-3.50
(3.25-3.50
(4.80-5.20
(4.80-5.20
(4.80-5.20
(4.80-5.20
(4.80-5.20
(4.80-5.20
(11.50-12.50
(11.50-12.50
(14.00-16.00
(3.25-3.50
(3.25-3.50
(4.80-5.20
(4.80-5.20
(4.80-5.20
(11.50-12.50
(11.50-12.50
(22.00-26.00
(22.00-26.00
(22.00-26.00
OUTPUT 2
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
V)
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
50
50
50
50
31
25
20
17
10
9
7
5
40
40
40
40
40
40
40
40
8
8
6
6
5
20
20
20
20
20
10
10
4
4
4
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
5.0
12.0
15.0
24.0
5.0
12.0
15.0
24.0
12.0
24.0
12.0
24.0
15.0
12.0
15.0
12.0
15.0
12.0
12.0
12.0
5.0
15.0
15.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
(4.8-16.0
(4.8-16.0
(4.8-16.0
(19.0-28.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(19.0-28.0
(11.5-12.5
(22.0-26.0
(11.5-12.5
(22.0-26.0
(14.0-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
OUTPUT 3
4.0
4.0
4.0
2.5
4.0
4.0
4.0
2.5
6.0
3.0
6.0
3.0
5.0
4.0
3.0
4.0
3.0
4.0
4.0
4.0
4.0
4.0
3.0
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
12.0
15.0
12.0
15.0
5.0
5.0
15.0
5.0
5.0
15.0
V
V
V
V
V
V
V
V
V
V
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
(4.8-16.0
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
V) @
4
3
4
3
4
4
3
4
4
3
A
A
A
A
A
A
A
A
A
A
MODULE
CODE
SZ
S1
S2
S3
SF
SG
S4
S5
S6
S7
S8
S9
U5
U6
U7
U8
U1
U2
U3
U4
R6(1)
R4(1)
R1(1)
R5(1)
R2(1)
T3
T4
T1
T2
T8
T6
T10
T11
T9
T7
1. R modules do not have signals or control facilities.
2. Output V2 & V3 of U & T modules can supply up to 5 A in certain applications dependent on other rail loadings. Contact sales for details.
3. Also available from Farnell and Newark.
MODULE
SIZE
..
AC-DC
LP & LP-MD
Model Configuration
AC-DC
LP
Preconfigured Models - Industrial
Output
Power Max
Output 1
Output 2
Output 3
Output 4
5.0 V @ 50 A
12.0 V @ 20 A
250 W
24.0 V @ 10 A
48.0 V @
350 W
5A
5.0 V @ 50 A
5.0 V @ 50 A
12.0 V @ 20 A
12.0 V @ 20 A
5.0 V @ 50 A
3.3 V @ 40 A
12.0 V (4.8-16.0 V) @ 4 A
5.0 V @ 50 A
12.0 V @ 10 A
12.0 V (4.8-16.0 V) @ 4 A
12.0 V @ 20 A
12.0 V @ 20 A
450 W
5.0 V (4.8-16.0 V) @ 4.0 A
5.0 V @ 50 A
3.3 V @ 40 A
12.0 V (4.8-16.0 V) @ 4 A
5.0 V @ 50 A
12.0 V @ 10 A
12.0 V (4.8-16.0 V) @ 4 A
5.0 V (4.8-16.0 V) @ 4.0 A
3.3 V @ 40 A
5.0 V @ 40 A
12.0 V (4.8-16.0 V) @ 4 A
24.0 V (19.0-28.0 V) @ 2.5 A
Industrial Version
Model Number
P3S3FE3
P3S4FE3
P3S6FE3
P3S9FE3
P4S3S3FE4
P4S4S4FE4
P4S3U6FE4
P4S3T6FE4
P5S4S4FE5
P5S3U6FE5
P5S3T6FE5
P5U4U6FE5
Model Number Example - Industrial (P) Versions
Chassis Power
Module Position 2
Module Position 1
Fan Assembly Style
Parallel Option
P3
S3
T1
FE3
01
Choose the chassis code first:
P3 = 250 W Chassis
P4 = 350 W Chassis
P5 = 450 W Chassis
Add any
or
module
e.g. S3 = Single 5 V
Add any
or
module
e.g. T1 = Triple 5 V/12 V/12 V
P3 Model
Add fan cover assembly.
Add parallel option if required
e.g. FE3 = End fan assembly
for 250 W chassis
2 x S module 1.8-15 V = 01
2 x S module 24-48 V = 02
Leave blank for open U-channel
Leave blank if not required
FE(x) End Fan
Screw terminal AC connections
NOTE:
Model number format and module position may change dependent on module configuration chosen.
Connector kits available. Order part number LP CONN KIT.
Fan Assemblies
Alternative fan assemblies are available. Consult sales for details.
FTx Top Fan. Molex header AC connections
End Fan. IEC AC connections
Output
Power Max
Output 1
Output 2
Output 3
Output 4
5.0 V @ 50 A
12.0 V @ 20 A
250 W
24.0 V @ 10 A
48.0 V @
350 W
450 W
5A
5.0 V @ 50 A
5.0 V @ 50 A
12.0 V @ 20 A
12.0 V @ 20 A
5.0 V @ 50 A
3.3 V @ 40 A
12.0 V (4.8-16.0 V) @ 4 A
5.0 V @ 50 A
12.0 V @ 10 A
12.0 V (4.8-16.0 V) @ 4 A
12.0 V @ 20 A
12.0 V @ 20 A
5.0 V (4.8-16.0 V) @ 4.0 A
5.0 V @ 50 A
3.3 V @ 40 A
12.0 V (4.8-16.0 V) @ 4 A
5.0 V @ 50 A
12.0 V @ 10 A
12.0 V (4.8-16.0 V) @ 4 A
5.0 V (4.8-16.0 V) @ 4.0 A
3.3 V @ 40 A
5.0 V @ 40 A
12.0 V (4.8-16.0 V) @ 4 A
24.0 V (19.0-28.0 V) @ 2.5 A
Medical Version
Model Number
M3S3ME3
M3S4ME3
M3S6ME3
M3S9ME3
M4S3S3ME4
M4S4S4ME4
M4S3U6ME4
M4S3T6ME4
M5S4S4ME5
M5S3U6ME5
M5S3T6ME5
M5U4U6ME5
Notes
1. Medical versions shown include EMC class B fan assembly.
Model Number Example - Medical (M) Versions
Chassis Power
Module Position 2
Module Position 1
Fan Assembly Style
Parallel Option
M3
S3
T1
ME3
01
Choose the chassis code first:
M3 = 250 W Chassis
M4 = 350 W Chassis
M5 = 450 W Chassis
Add any
or
module
e.g. S3 = Single 5 V
Add any
or
module
e.g. T1 = Triple 5 V/12 V/12 V
Add fan cover assembly.
Add parallel option if required
e.g. ME3 = End fan assembly
for 250 W chassis
2 x S module 1.8-15 V = 01
2 x S module 24-48 V = 02
Leave blank for open U-channel
Leave blank if not required
ME(x) End Fan
M3 Model
Screw terminal AC connections Class B
FE(x) End Fan
NOTE:
Model number format and module position may change
dependent on module configuration chosen.
Connector kits available. Order part number LP CONN KIT.
Screw terminal AC connections Class A
Fan Assemblies
End Fan. IEC Dual-fused and switched
AC connections. Class B
End Fan. IEC AC connections. Class A
Alternative fan assemblies are available. Consult sales for details.
Top Fan. Molex header AC connections
AC-DC
LP-MD
Preconfigured Models - Medical
AC-DC
LP & LP-MD
Signals & Controls
AC OK/Power Fail
Global Inhibit
When fitted in module position 2 of the chassis, pins 10 and 2 provide
a minimum of 5 ms warning of loss of output regulation.
Inhibiting the module fitted in position 2 will inhibit all outputs of other
modules (fans remain running if fitted). If individual inhibit is required
on the module fitted in chassis postion 2 alternative configurations are
available. Please consult our application engineering team.
5V
330Ω
AC OK (HIGH)
Inhibit
PIN 10
INTERNAL TO PSU
(Open Collector)
Pins 6 and 2 (return) provide on/off control of the module. Applying a
logic ‘0’ between these pins turns the outputs off.
PIN 2
AC NOT OK
(LOW)
OUTPUTS ON
5V
OR
FLOATING
Current Share
Connecting pins 4 & 2 of like part number modules (3 maximum)
within the same chassis or separate chassis will force the modules to
current share the outputs.
0V
OUTPUTS OFF
PIN 6
PIN 2
(Reverse logic option available, i.e. high for outputs off or low for
outputs on).
Module 1
Module 2
Module 3
Modules in Parallel
Pin 2
Pin 4
Pin 2
Pin 2
Pin 4
Pin 4
Single output modules with the same part number and V1 of dual and
triple output modules can be paralleled to obtain increased output
current. These modules can either be fitted in the same chassis or a
different chassis with their outputs connected directly together and
current share connections made, see Current Share.
DC OK
Modules in Series
Pins 8 and 2 provide notification that the output voltage is within
regulation via a logic 1.
Single output modules can be connected in series to obtain alternate
output voltages not available from a single module. For example a 10 V
(SG module) can be connected in series with a 12 V (S4 module) to
obtain an output voltage of 22 V.
5V
Remote Sense
330Ω
DC OK (HIGH)
PIN 8
INTERNAL TO PSU
(Open Collector)
DC NOT OK
(LOW)
Pins 1 (+ve) and 2 (-ve) provide compensation for voltage drops in
application wiring up to a maximum of 0.5 V.
Remote Sense is not fitted to (R) modules and V2 & V3 of (U) and
(T) modules.
PIN 2
Housekeeping
(Reverse logic option available, i.e. high for DC NOT OK).
Notes
1. (R) module does not have these signal facilities.
A 5 V standby voltage rated at 1 A is fitted to each chassis.
Weight: 1.40 lb (0.64 kg) approx
See Airflow Curves
8.00 (203.2)
1.50
(38.1)
5.50 (139.7)
+
-
+
-
0.75
(19.1)
OUTPUT TERMINAL BLOCK
M3.5 HARDWARE, 0.375 CENTRES
5.00
(127.0)
3.50
(88.9)
LOGIC CONNECTOR
AMP PN 102617-3
-
6-32 UNC THD
OUTPUT HARDWARE
A
+
OUTPUT HARDWARE
4X M4-0.7 THD
0.15 (3.8) MAX SCREW PENETRATION
1.50
(38.1)
A
AC INPUT CONNECTOR
MOLEX PN 26-60-4050
MATING PLUG:
MOLEX PN 09-50-3051
CONTACT:
18-20AWG, MOLEX PN 08-52-0072
0.75
(19.1)
VIEW A-A
1.50
(38.1)
5.50 (139.7)
2X M4-0.7 THD
0.15 (3.8) MAX SCREW PENETRATION
FE3 Fan Assembly
Weight: 1.90 lb (0.86 kg) approx
8.30 (210.8)
1.50
(38.1)
M3-0.5 THD
ADDITIONAL MTG. HOLE IF REQUIRED
0.15 (3.8) MAX. SCREW PENETRATION
5.50 (139.7)
1.56
(39.7)
9.50 (241.3)
.75
(19.1)
2.50
(63.5)
3.50
(88.9)
5.00
(127.0)
4X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
1.50
(38.1)
0.75
(19.1)
AIR FLOW
POWER SUPPLY
OUTPUT TERMINATION AREA
2X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
5.50 (139.7)
AC INPUT
3 POSITION TERMINAL BLOCK
L
N
GND
Notes
1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request.
2. Mating connector kit available. Order part number LP CONN KIT.
3. Dimensions in inches (mm).
AC-DC
LP & LP-MD
Mechanical Details 250 Watt P3 & M3 Models
U Channel
U-Channel
Weight: 1.50 lb (0.68 kg) approx
See Airflow Curves
9.00 (228.6)
1.50
(38.1)
6.00 (152.4)
-
0.75
(19.1)
-
+
OUTPUT TERMINAL BLOCK
M3.5 HARDWARE, 0.375 CENTRES
+
AC-DC
LP & LP-MD
Mechanical Details 350 Watt P4 & M4 Models
5.00
(127.0)
3.50
(88.9)
LOGIC CONNECTOR
AMP PN 102617-3
-
6-32 UNC THD
OUTPUT HARDWARE
A
+
4X M4-0.7 THD
0.15 (3.8) MAX SCREW PENETRATION
1.50
(38.1)
A
L
N
GND
0.75
(19.1)
AC INPUT CONNECTOR
MOLEX PN 26-60-4050
MATING PLUG:
MOLEX PN 09-50-3051
CONTACT:
18-20AWG, MOLEX PN 08-52-0072
VIEW A-A
1.50
(38.1)
6.00 (152.4)
2X M4-0.7 THD
0.15 (3.8) MAX SCREW PENETRATION
FE4 Fan Assembly
Weight: 2.00 lb (0.91 kg) approx
9.30
(236.2)
1.50
(38.1)
M3-0.5 THD
ADDITIONAL MTG. HOLE IF REQUIRED
0.15 (3.8) MAX. SCREW PENETRATION
10.50 (266.7)
1.56
(39.7)
6.00 (152.4)
0.75
(19.1)
2.50
(63.5)
3.50
(88.9)
5.00
(127.0)
AIRFLOW
4X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
1.50
(38.1)
0.75
(19.1)
2X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
POWER SUPPLY
OUTPUT TERMINATION AREA
6.00 (152.4)
AC INPUT
3 POSITION TERMINAL BLOCK
L
N
GND
Notes
1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request.
2. Mating connector kit available. Order part number LP CONN KIT.
3. Dimensions in inches (mm).
ME3 Fan Assembly (M Models Only)
Weight: 2.00 lb (0.91 kg) approx
8.30 (210.8)
1.50
(38.1)
M3-0.5 THD
ADDITIONAL MTG. HOLE IF REQUIRED
0.15 (3.8) MAX. SCREW PENETRATION
AC INPUT
3 POSITION TERMINAL BLOCK
5.50 (139.7)
1.56
(39.7)
POWER SUPPLY
OUTPUT TERMINATION AREA
0.75
(19.1)
2.50
(63.5)
3.50
(88.9)
L
N
GND
5.00
(127.0)
AIRFLOW
4X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
10.25 (260.4)
1.50
(38.1)
5.50 (139.7)
2X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
0.75
(19.1)
ME4 Fan Assembly (M Models Only)
Weight: 2.16 lb (0.98 kg) approx
9.30 (236.2)
1.50
(38.1)
M3-0.5 THD
ADDITIONAL MTG. HOLE IF REQUIRED
0.15 (3.8) MAX. SCREW PENETRATION
AC INPUT
3 POSITION TERMINAL BLOCK
1.56
(39.7)
6.00 (152.4)
POWER SUPPLY
OUTPUT TERMINATION AREA
0.75
(19.1)
2.50
(63.5)
5.00
(127.0)
3.50
(88.9)
4X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
1.50
(38.1)
6.00 (152.4)
L
N
GND
AIRFLOW
11.25 (285.8)
2X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
0.75
(19.1)
Notes
1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request.
2. Mating connector kit available. Order part number LP CONN KIT.
3. Dimensions in inches (mm).
AC-DC
LP & LP-MD
Mechanical Details 250/350 Watt M3 & M4
AC-DC
LP & LP-MD
Mechanical Details 450 Watt P5 & M5 Models
450 Watts - P5 and M5 models are always shipped with a fan cover to ensure adequate cooling.
FE5 Fan Assembly
Weight: 2.50 lb (1.14 kg) approx
1.50
(38.1)
1.68
(42.5)
6.00 (152.4)
10.50 (266.7)
0.75
(19.1)
AIR FLOW
5.00
(127.0)
3.50
(88.9)
L N G
L
N
GND
AC INPUT
3 POSITION TERMINAL BLOCK
4X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
POWER SUPPLY
OUTPUT TERMINATION AREA
2X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
1.50
(38.1)
8.00 (203.2)
0.75
(19.1)
ME5 Fan Assembly (M Models Only)
Weight: 2.62 lb (1.19 kg) approx
M3-0.5 THD
ADDITIONAL MTG. HOLE IF REQUIRED
0.15 (3.8) MAX. SCREW PENETRATION
POWER SUPPLY
OUTPUT TERMINATION AREA
9.80 (248.9)
1.50
(38.1)
1.68
(42.5)
6.00 (152.4)
AC INPUT
3 POSITION TERMINAL BLOCK
0.75
(19.1)
2.50
(63.5)
3.50
(88.9)
5.00
(127.0)
L
N
GND
AIR FLOW
4X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
11.75 (298.5)
2X M4-0.7 THD
0.15 (3.8) MAX. SCREW PENETRATION
1.50
(38.1)
8.00 (203.2)
0.75
(19.1)
Notes
1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request.
2. Mating connector kit available. Order part number LP CONN KIT.
3. Dimensions in inches (mm).
The curves denote chassis
derating. Output modules must be
derated by the same proportion.
Formula for converting CFM to LFM:
Formula for converting LFM to CFM:
CFM x 144
LFM =
CFM =
144
P4 & M4 Models
P3 & M3 Models
400
300
350
300 LFM
225 LFM
150 LFM
Convection
200
150
100
Power (Watts)
250
Power (Watts)
LFM x (total cross section of airflow path (Inches2))
(total cross section of airflow path (Inches2))
300
250
200
150
100
50
50
0
0
50
25
0
0
70
50
25
70
Temperature (ºC)
Temperature (ºC)
Output Module Connection Details
Weight: 0.50 lb (227 g) approx
Single Output (S)
VOLTAGE
ADJUST (BEHIND)
M4-0.7 THD
OUTPUT TERMINALS
OUTPUT TERMINAL BLOCK
M3.5 0.375 CENTERS
LOGIC
CONNECTOR
LOGIC
CONNECTOR
+
VOLTAGE
ADJUST
+
-
10
2
10
2
9
1
9
1
Dual Output (R)
Logic Connector AMP 87631-5
Pin
Function
1
+sense (V1)
2
-sense (V1)
3
+sense (V1)
4
Current share
5
6
Inhibit
7
-sense (V1)
8
DC OK
9
Module Size
10
Power fail
Weight: 0.52 lb (236 g) approx
OUTPUT TERMINAL BLOCK
6-32 0.375 CENTERS
OUTPUT 2
+
OUTPUT 1
-
+
-
Module Size
VOLTAGE ADJUST
Weight: 0.62 lb (282 g) approx
Dual Output (U)
V1
V2 MATING CONNECTOR
MOLEX 39-01-2025
VOLTAGE ADJUST
(BEHIND)
-
+
V2
10
2
9
1
LOGIC
CONNECTOR
+
-
V1 OUTPUT TERMINAL BLOCK (EUROSTYLE 10.16mm)
WIDE RANGE: 6 TO 18 AWG
WIRE STRIP LENGTH: 0.25” (6.35mm)
TIGHTENING TORQUE: 7 IN-lbs
Triple Output (T)
Weight: 0.70 lb (318 g) approx
OUTPUT TERMINAL
BLOCK
6-32 0.375 CENTERS
+
OP 1 VOLTAGE
ADJUST
(BEHIND)
MULTI-OUTPUT
POWER CONNECTOR
LOGIC
CONNECTOR
10
2
6
4
9
1
3
1
OP 3 VOLTAGE ADJUST
Output Connector
Molex 39-01-2060
Pin
Function
1 Output RTN V2
2
3 Output RTN V3
4
Output 2+
5
6
Output 3+
Logic Connector AMP 87631-5
Pin
Function
1
+sense (V1)
2
-sense (V1)
3
+sense (V1)
4
Current share
5
6
Inhibit
7
-sense (V1)
8
DC OK
9
10
Power fail
Module Size
Logic Connector AMP 87631-5
Pin
Function
1
+sense (V1)
2
-sense (V1)
3
+sense (V1)
4
Current share
5
6
Inhibit
7
-sense (V1)
8
DC OK
9
10
Power fail
Module Size
OP 2 VOLTAGE ADJUST
17-Apr-07
AC-DC
LP & LP-MD
Airflow Curves - U-Channel Models