MODELS WITH -0XX SUFFIX
-00X = NO INPUT JUMPERS ON TRANSFORMER
DASH NO.
DESCRIPTION
-001
0.375" Terminal Block Output Connector. See model specific BOM
for number of terminals.
-002
OVP12 or OVP24 set as listed below (single output models only)
12V = 13.8 ±0.8V
15V = 17.0 ±1.0V
24V = 27.0 ±1.0V
28V = 31.0 ±1.0V
-003
Adjustable 9-15V or 12-15V output set to 12V.
Use appropriate
ATE program.
-004
Split type lockwashers installed on TO-3 transistors.
-005
Combination of -001 and -003. Use instructions for -001 AND
-003 above. Install sense jumpers for 5V output.
-006
Seal all voltage and current adjust pots.
MODELS WITH -5XX SUFFIX
-50X = INPUT JUMPERS SET FOR 120V OPERATION
DASH NO.
DESCRIPTION
-500
Jumper pins 1 to 3 and 2 to 4 on transformer using 20GA buss
wire. Apply AC input to terminals 1 and 4.
All modifications listed below must include the jumpers for -500 above.
-501
0.375" Terminal Block Output Connector. See model specific BOM
for number of terminals.
-502
OVP12 or OVP24 set as listed below (single output models only)
12V = 13.8 ±0.8V
15V = 17.0 ±1.0V
24V = 27.0 ±1.0V
28V = 31.0 ±1.0V
-503
Adjustable 9-15V or 12-15V output set to 12V.
Use appropriate
ATE program.
-504
Split type lockwashers installed on TO-3 transistors.
-505
Combination of -501 and -503. Use instructions for -501 AND
-503 above. Install sense jumpers for 5V output.
-506
Seal all voltage and current adjust pots.
RECORD OF REVISIONS
LTR
ECN
G
SL POWER ELECTRONICS CORP.
INC
DATE
4733
DH
4/6/92
H
5666
DH
4/9/94
J
7012
DF
9/28/98
K
DESCRIPTION
45067 Removed Label note
Date Printed: 4/30/09
R.J.
4/17/09
6050 KING DR. BLDG. A,
Ventura, CA 93033 - 805-486-4565
DRAWN
DATE
1/3/94
CHECK
DRAWING NO.
41-32492-0000
DATE
SHT 1 OF 3
REV
K
MODELS WITH -6XX SUFFIX
-60X = INPUT JUMPERS SET FOR 100V OPERATION
DASH NO.
DESCRIPTION
-600
Jumper pins 1 to 3 and 2 to 4 on transformer using 20GA buss
wire. Apply AC input to terminals 1 and 5.
All modifications listed below must include the jumpers for -600 above.
-601
0.375" Terminal Block Output Connector. See model specific BOM
for number of terminals.
-602
OVP12 or OVP24 set as listed below (single output models only)
12V = 13.8 ±0.8V
15V = 17.0 ±1.0V
24V = 27.0 ±1.0V
28V = 31.0 ±1.0V
-603
Adjustable 9-15V or 12-15V output set to 12V.
Use appropriate
ATE program.
-604
Split type lockwashers installed on TO-3 transistors.
-605
Combination of -601 and -603. Use instructions for -601 AND
-603 above. Install sense jumpers for 5V output.
-606
Seal all voltage and current adjust pots.
MODELS WITH -7XX SUFFIX
-70X = INPUT JUMPERS SET FOR 220V OPERATION
DASH NO.
DESCRIPTION
-700
Jumper pins 2 to 3 on transformer using 20GA buss wire. Apply
AC input to terminals 1 and 5.
All modifications listed below must include the jumpers for -700 above.
-701
0.375" Terminal Block Output Connector. See model specific BOM
for number of terminals.
-702
OVP12 or OVP24 set as listed below (single output models only)
12V = 13.8 ±0.8V
15V = 17.0 ±1.0V
24V = 27.0 ±1.0V
28V = 31.0 ±1.0V
-703
Adjustable 9-15V or 12-15V output set to 12V.
Use appropriate
ATE program.
-704
Split type lockwashers installed on TO-3 transistors.
-705
Combination of -701 and -703. Use instructions for -701 AND
-703 above. Install sense jumpers for 5V output.
-706
Seal all voltage and current adjust pots.
Page 2 of 3
CONVERSION SHEET
41-32492-0000
MODELS WITH -8XX SUFFIX
-80X = INPUT JUMPERS SET FOR 240V OPERATION
DASH NO.
DESCRIPTION
-800
Jumper pins 2 to 3 on transformer using 20GA buss wire. Apply
AC input to terminals 1 and 4.
All modifications listed below must include the jumpers for -800 above.
-801
0.375" Terminal Block Output Connector. See model specific BOM
for number of terminals.
-802
OVP12 or OVP24 set as listed below (single output models only)
12V = 13.8 ±0.8V
15V = 17.0 ±1.0V
24V = 27.0 ±1.0V
28V = 31.0 ±1.0V
-803
Adjustable 9-15V or 12-15V output set to 12V.
Use appropriate
ATE program.
-804
Split type lockwashers installed on TO-3 transistors.
-805
Combination of -801 and -803. Use instructions for -801 AND
-803 above. Install sense jumpers for 5V output.
-806
Seal all voltage and current adjust pots.
Page 3 of 3
CONVERSION SHEET