AC-DC Chassis Mount 50-150 Watts THE XPERTS IN POWER PBA Series Universal PFC Input • Convection Cooled • Low Profile <1U • Adjustable Output Voltage • Optional Remote On/Off • Optional Din Rail Mount • High Efficiency • Specification Input General Input Voltage • Input Frequency Input Current Inrush Current Power Factor Leakage Current • • • • • 85-264 VAC (120-370 VDC) 50 VAC (70 VDC) (Optional, contact sales) 47-63 Hz 2/1 A max at 115/230 VAC 20/40 A max at 115/230 VAC EN61000-3-2 compliant 0.75 mA max, optional 0.15 mA - add suffix “-G” to model numbers Output Output Voltage Output Voltage Adjustment Output Voltage Set Point Minimum Load Start-Up Time Drift Line Regulation Load Regulation Hold-up Time Output Ripple & Noise Overvoltage Protection Overload Protection • • 3.3 VDC to 48 VDC +10/-15% • ±3% Vnom • • • • • • • • No minimum load required 350 ms typical ±0.6% max ±1% max ±2% max 15 ms typical 1% of Vn pk-pk operates at 120-140% of Vnom • Remote ON/OFF • Operates at 105% of rated current, autorecovery Optional. Add suffix “-R” to model number Efficiency Isolation • • Switching Frequency • Indications • 85% typical 3000 VAC Input to Output 2000 VAC Input to Ground 500 VAC Output to Ground 60-550 kHz PFC, 130kHz PWM Green LED for unit operating Environmental Operating Temperature Storage Temperature Relative Humidity Shock Vibration • -10 °C to +70 °C, see derating curve • -20 °C to +75 °C • • • 20-90% non-condensing 20 G 11 ms,once each x, y and z axis 2 G 10-55Hz for 3 min periods for 60 min along each x, y and z axis Emissions • ESD Susceptibility Radiated Susceptibility EFT/Burst Surge • EN55022 Level B conducted EN55022 Level B radiated EN61000-4-2 Level 4 • EN61000-4-3 Level 3 • • Voltage dips and interruptions Safety Approvals • EN61000-4-4 Level 4 EN61000-4-5 Level 3 line to line EN61000-4-5 Level 4 line to earth EN61000-4-11 EMC & Safety • UL60950, CSA 60950 EN60950, EN50178 • • www.xpplc.com [email protected] OUTPUT VOLTAGE & CURRENT RATINGS Output Voltage 3.3 V (2.85-3.63) 5.0 V (4.00-5.50) 9.0 V (7.50-10.00) 12.0 V (10.0-13.2) 15.0 V (13.2-18.0) 24.0 V (19.2-27.0) 36.0 V (28.8-39.6) 48.0 V (39.0-53.0) Output Current 10 A 10 A 5.6 A 4.3 A 3.5 A 2.2 A 1.4 A 1.1 A PBA50F Regulation Line ±20 mV ±20 mV ±36 mV ±48 mV ±60 mV ±96 mV ±144 mV ±192 mV Load ±40 mV ±40 mV ±100 mV ±100 mV ±120 mV ±150 mV ±240 mV ±240 mV Rippled Noise(1) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 250 mV 250 mV Efficiency(2) Model 76% 82% 81% 82% 83% 84% 85% 85% PBA50F-3 PBA50F-5 PBA50F-9 PBA50F-12 PBA50F-15 PBA50F-24 PBA50F-36 PBA50F-48 Notes 1. Measured over a 20 MHz bandwidth and from 0 °C to +50 °C. 2. Measured at 230 VAC and 100% load. • Mechanical Details Weight 280g max (without cover) Measurements are in inches (mm) Options available: Conformal coating: add suffix “-C “ Low leakage current: add suffix “-G” (0.15 mA max) add suffix “-E” (0.5 mA max) Vertical screw terminal blocks: add suffix “-T” Cover Fitted: add suffix “-N” Remote ON/OFF: add suffix “-R” DIN rail mount: add suffix “-N1” Remote output voltage adjustment potentiometer: add suffix “-V” www.xpplc.com [email protected] OUTPUT VOLTAGE & CURRENT RATINGS Output Voltage 3.3 V (2.85-3.63) 5.0 V (4.00-5.50) 9.0 V (7.50-10.00) 12.0 V (10.0-13.2) 15.0 V (13.2-18.0) 24.0 V (19.2-27.0) 36.0 V (28.8-39.6) 48.0 V (39.0-53.0) Output Current 15 A 15 A 8.4 A 6.3 A 5A 3.2 A 2.1 A 1.6 A PBA75F Regulation Line ±20 mV ±20 mV ±36 mV ±48 mV ±60 mV ±96 mV ±144 mV ±192 mV Load ±40 mV ±40 mV ±100 mV ±100 mV ±120 mV ±150 mV ±240 mV ±240 mV Rippled Noise(1) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 250 mV 250 mV Efficiency(2) Model 78% 83% 82% 83% 84% 85% 86% 86% PBA75F-3 PBA75F-5 PBA75F-9 PBA75F-12 PBA75F-15 PBA75F-24 PBA75F-36 PBA75F-48 Notes 1. Measured over a 20 MHz bandwidth and from 0 °C to +50 °C. 2. Measured at 230 VAC and 100% load. • Mechanical Details Weight 350g max (without cover) Measurements are in inches (mm) Options available: Conformal coating: add suffix “-C “ Low leakage current: add suffix “-G” (0.15 mA max) add suffix “-E” (0.5 mA max) Vertical screw terminal blocks: add suffix “-T” Cover Fitted: add suffix “-N” Remote ON/OFF: add suffix “-R” DIN rail mount: add suffix “-N1” Remote output voltage adjustment potentiometer: add suffix “-V” www.xpplc.com [email protected] OUTPUT VOLTAGE & CURRENT RATINGS Output Voltage 3.3 V (2.85-3.63) 5.0 V (4.00-5.50) 9.0 V (7.50-10.00) 12.0 V (10.0-13.2) 15.0 V (13.2-18.0) 24.0 V (19.2-27.0) 36.0 V (28.8-39.6) 48.0 V (39.0-53.0) Output Current 20 A 20 A 10.5 A 8.5 A 7A 4.5 A 2.8 A 2.1 A PBA100F Regulation Line ±20 mV ±20 mV ±36 mV ±48 mV ±60 mV ±96 mV ±144 mV ±192 mV Load ±40 mV ±40 mV ±100 mV ±100 mV ±120 mV ±150 mV ±240 mV ±240 mV Rippled Noise(1) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 250 mV 250 mV Efficiency(2) Model 79% 84% 82% 83% 86% 86% 86% 86% PBA100F-3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 Notes 1. Measured over a 20 MHz bandwidth and from 0 °C to +50 °C. 2. Measured at 230 VAC and 100% load. • Mechanical Details Weight 440g max (without cover) measurements are in inches (mm) Options available: Conformal coating: add suffix “-C “ Low leakage current: add suffix “-G” (0.15 mA max) add suffix “-E” (0.5 mA max) Vertical screw terminal blocks: add suffix “-T” Cover Fitted: add suffix “-N” Remote ON/OFF: add suffix “-R” DIN rail mount: add suffix “-N1” Remote output voltage adjustment potentiometer: add suffix “-V” www.xpplc.com [email protected] OUTPUT VOLTAGE & CURRENT RATINGS Output Voltage 3.3 V (2.85-3.63) 5.0 V (4.00-5.50) 9.0 V (7.50-10.00) 12.0 V (10.0-13.2) 15.0 V (13.2-18.0) 24.0 V (19.2-27.0) 36.0 V (28.8-39.6) 48.0 V (39.0-53.0) Output Current 30 A 30 A 16.7 A 13 A 10 A 6.5 A 4.3 A 3.3 A PBA150F Regulation Line ±20 mV ±20 mV ±36 mV ±48 mV ±60 mV ±96 mV ±144 mV ±192 mV Load ±40 mV ±40 mV ±100 mV ±100 mV ±120 mV ±150 mV ±240 mV ±240 mV Rippled Noise(1) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 250 mV 250 mV Efficiency(2) Model 82% 86% 85% 86% 87% 88% 88% 88% PBA150F-3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48 Notes 1. Measured over a 20 MHz bandwidth and from 0 °C to +50 °C. 2. Measured at 230 VAC and 100% load. • Mechanical Details Weight 560g max (without cover) measurements are in inches (mm) Options available: Conformal coating: add suffix “-C “ Low leakage current: add suffix “-G” (0.15 mA max) add suffix “-E” (0.5 mA max) Vertical screw terminal blocks: add suffix “-T” Cover Fitted: add suffix “-N” Remote ON/OFF: add suffix “-R” DIN rail mount: add suffix “-N1” Remote output voltage adjustment potentiometer: add suffix “-V” www.xpplc.com [email protected] Rev 2.0