ZOWIE UGC20JH

UGC20DH THRU UGC20KH
SURFACE MOUNT GLASS PASSIVATED JUNCTION ULTRAFAST EFFICIENT RECTIFIER
Reverse Voltage - 200 to 800 Volts
ED
T
N
E
T
PA
Forward Current - 2.0 Amperes
2010
FEATURES
.181(4.60)
.173(4.40)
*
*
*
*
*
*
*
*
*
*
*
.002(0.05)
0)
0.5
20(
0
R0.
0.091(2.30)
0.083(2.10)
0.045(1.15)
0.045(1.15)
0.029(0.75)
0.029(0.75)
0.046(1.16)
Halogen-free type
Lead free product, compliance to RoHS
Leadless chip form, no lead damage
Lead-free solder joint, no wire bond & lead frame
Low profile package
For surface mounted applications
Built-in strain relief
Low power loss, High efficiency
High current capability
High surge capacity
Plastic package has Underwriters Laboratory Flammability
Classification 94V-0
0.034(0.86)
MECHANICAL DATA
Case : Packed with FRP substrate and epoxy underfilled
Terminals : Pure Tin plated (Lead-Free),
solderable per MIL-STD-750, Method 2026.
Polarity : Cathode Band, Laser marking
Weight : 0.02 gram
*Dimensions in inches and (millimeters)
TM
TM
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
UGC20
o
Ratings at 25 C ambient temperature
unless otherwise specified.
SYMBOLS
UNITS
DH
GH
JH
KH
Maximum repetitive peak reverse voltage
VRRM
200
400
600
800
Volts
Maximum RMS voltage
VRMS
140
280
420
560
Volts
VDC
200
400
600
800
Volts
Maximum DC blocking voltage
o
Maximum average forward rectified current at TL=110 C
Peak forward surge current 8.3ms single half sine-wave
I (AV)
2.0
Amps
IFSM
50
Amps
superimposed on rated load
Maximum instantaneous forward voltage at 2.0 A
VF
o
Maximum DC reverse current
TA=25 C
at rated DC blocking voltage
TA=125 C
o
0.95
1.25
1.7
2.2
Volts
5
IR
100
uA
Maximum reverse recovery time (NOTE 1)
trr
35
nS
Typical junction capacitance (NOTE 2)
CJ
25
pF
TJ,TSTG
-55 to +175
Operating junction and storage temperature range
o
C
NOTES : (1) Reverse recovery test condition : IF 0.5A, IR=1.0A, Irr=0.25A
(2) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
REV. 2
Zowie Technology Corporation
RATINGS AND CHARACTERISTIC CURVES UGC20DH THRU UGC20KH
FIG.1 - FORWARD CURRENT DERATING CURVE
FIG.2 - MAXIMUM NON-REPETITIVE
PEAK FORWARD SURGE CURRENT
70
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED
CURRENT, AMPERES
2.00
1.50
1.00
0.50
RESISTIVE OR
INDUCTIVE LOAD
0
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
60
50
40
30
20
10
0
0
25
50
75
100
125
150
1
175
10
o
100
NUMBER OF CYCLES AT 60Hz
LEAD TEMPERATURE, C
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
FIG.3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
100
10.00
INSTANTANEOUS REVERSE LEAKAGE
CURRENT, MICROAMPERES
0J
K
UG
C2
0
G
C2
C20
UG
UG
20D
1.00
UGC
IINSTANTANEOUS FORWARD CURRENT,
AMPERES
PULSE WIDTH=300uS
1% DUTY CYCLE
0.10
0.01
0.2
0.6
1.0
1.4
1.8
o
TJ = 150 C
10
o
TJ = 125 C
1
o
TJ = 25 C
0.1
2.2
0
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
20
40
60
80
100
110
PERCENT OF RATED PEAK REVERSE VOLTAGE,%
FIG.5 - TYPICAL JUNCTION CAPACITANCE
200
JUNCTION CAPACITANCE, pF
o
TJ = 25 C
100
60
40
20
10
6
4
2
1
.1
.2
.4
1.0
2
4
10
20
40
100
REVERSE VOLTAGE, VOLTS
REV. 2
Zowie Technology Corporation