DATA SHEET Part Number: SL22 50004 Ordering Different Lead Types: Inside Kinked Leads Outside Kinked Leads Use -A after Ametherm’s part # Use -B after Ametherm’s part # For example: to order an inside kinked lead use part number SL22 50004-A D D D T C B L S S S STRAIGHT LEADS OUTSIDE KINKED LEADS INSIDE KINKED LEADS Electrical Specifications: Mechanical Specifications: Resistance @ 25°C Max Steady State Current Up to 65°C Max Recommended Voltage Max Recommended Energy Rating (Joules) Actual Failure Point of Instantaneous Energy (Joules) Resistance @ 100% of Max Current Resistance @ 50% of Max Current Body Temperature @ 100% Current Rating Dissipation Constant Thermal Time Constant Material Type Upper Limit of the Body Temperature Max Recommended Capacitance @ 120VAC/240 VAC 50.0 Ω ± 20% 4.0 A 265 VAC 80.0 J 175.0 J 0.440 Ω 0.900 Ω 162 °C 32.4mW/°C 94 seconds “M” 270 °C 5500µ/1300µF UL File Number: #E209153 D T Lead Diameter S L Straight Leads Coating Run Down B C 20.0 ± 1.0 mm 5.0 ± 0.2 mm 1.0 ± 0.1 mm 7.8 ± 2.0 mm 38.0 ± 9.0 mm 5.0 ± 1.0 mm 9.22 ± 1.0 mm 3.82 ± 1.0 mm Revision Date: March 19, 2003 Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701 Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670 www.ametherm.com