AOSMD AOZ1013

^lwNMNP=
EZBuck™ 3A Simple Buck Regulator
February 2006
General Description
The AOZ1013 is a high efficiency, simple to use, 3A buck
regulator. The AOZ1013 works from a 4.5V to 16V input
voltage range, and provides up to 3A of continuous output
current with an output voltage adjustable down to 0.8V.
Features
• 4.5V to 16V operating input voltage range
• 50 mΩ internal PFET switch for high
efficiency: up to 95%
• Internal soft start
• Output voltage adjustable to 0.8V
• 3A continuous output current
• Fixed 500kHz PWM operation
• Cycle-by-cycle current limit
• Short-circuit protection
• Thermal shutdown
• Small size SO-8 packages
The AOZ1013 comes in SO-8 packages and is rated over a
-40°C to +85°C ambient temperature range.
Applications
• Point of load dc/dc conversion
• PCIe graphics cards
• Set top boxes
• DVD drives and HDD
• LCD panels
• Cable modems
• Telecom/Networking/Datacom equipment
Typical Application
VIN
C1
10uF
VIN
From uPC
EN
L1
AOZ1013
4.7uH
VOUT
LX
COMP
+3.3V Output
@3A
R1
C2
FB
RC
AGND
PGND
R2
47uF
D1
CC
Figure 1. 3.3V/3A Buck Down Regulator
February 2006
www.aosmd.com
Page 1 of 16
^lwNMNP
Ordering Information
Part Number
AOZ1013AI
Ambient Temperature Range
-40°C to +85°C
Package
SO-8
Environmental
RoHS
Pin Configuration
VIN
1
PGND
2
AGND
FB
8
LX
7
LX
3
6
EN
4
5
COMP
SO-8
Pin Description
Pin Number
1
Pin Name
VIN
2
3
PGND
AGND
4
FB
5
6
COMP
EN
7,8
LX
Pin Function
Supply voltage input. When VIN rises above the UVLO threshold the
device starts up.
Power ground. Electrically needs to be connected to AGND.
Reference connection for controller section. Also used as thermal
connection for controller section. Electrically needs to be connected
to PGND.
The FB pin is used to determine the output voltage via a resistor
divider between the output and GND.
External loop compensation pin.
The enable pin is active high. Connect EN pin to VIN if not used. Do
not leave the EN pin floating.
PWM output connection to inductor. Thermal connection for output
stage.
Absolute Maximum Ratings(1)
Parameter
Supply Voltage (VIN)
LX to AGND
EN to AGND
FB to AGND
COMP to AGND
PGND to AGND
Junction Temperature (TJ)
Storage Temperature (TS)
ESD Rating(3)
February 2006
Recommend Operating Ratings(2)
Units
18V
-0.7V to VIN+0.3V
Parameter
Supply Voltage (VIN)
Output Voltage Range
Units
4.5V to 16V
0.8V to VIN
-0.3V to VIN+0.3V
-0.3V to 6V
-0.3V to 6V
-0.3V to +0.3V
+150°C
-65°C to +150°C
2kV
Ambient Temperature (TA)
Package Thermal Resistance
SO-8 (ΘJA)
-40°C to +85°C
82° C/W
www.aosmd.com
Page 2 of 16
^lwNMNP
Electrical Characteristics
TA = 25°C, VIN = VEN = 12V, VOUT = 3.3V unless otherwise specified.
Parameter
Symbol
Supply Voltage
Input Under-Voltage Lockout
Threshold
VIN
VUVLO
Supply Current (Quiescent)
IIN
Shutdown Supply Current
Feedback Voltage
Load Regulation
Line Regulation
Feedback Voltage Input Current
EN Input Threshold
IOFF
VFB
EN Input Hysteresis
Modulator
Frequency
Maximum Duty Cycle
Minimum Duty Cycle
Error Amplifier Voltage Gain
Error Amplifier Transconductance
Protection
Current Limit
Over-Temperature Shutdown
Limit
VHYS
Soft Start Interval
Output Stage
High-Side Switch On-Resistance
IFB
VEN
Conditions
MIN
TYP
4.5
VIN rising
VIN falling
IOUT = 0, VFB = 1.2V,
VEN >2V
VEN = 0V
4.00
3.70
2
0.782
Off threshold
On threshold
3
0.8
0.5
1
MAX
UNITS
16
V
V
V
mA
3
20
0.818
200
0.6
2.0
100
fO
DMAX
DMIN
350
100
500
600
6
500
200
ILIM
4
TJ rising
TJ falling
145
100
4
VIN = 12V
VIN = 5V
40
65
tSS
µA
V
%
%
nA
V
V
mV
kHz
%
%
V/V
µA/V
5
A
°C
°C
ms
50
85
mΩ
mΩ
Notes:
1. Exceeding the Absolute Maximum ratings may damage the device.
2. The device is not guaranteed to operate beyond the Maximum Operating ratings.
3. Devices are inherently ESD sensitive, handling precautions are required. Human body model rating: 1.5KΩ in series
with 100pF.
4. Specification in BOLD indicate an ambient temperature range of -40°C to +85°C. These specifications are guaranteed
by design.
February 2006
www.aosmd.com
Page 3 of 16
^lwNMNP
Functional Block Diagram
Vin
UVLO
&
POR
REFERENCE
&
BIAS
0.8V
FB
5V LDO
OTP
Internal +5V
REGULATOR
+
ISEN
SOFTSTART
+
+
EAMP
-
PWM
– COMP
PWM
CONTROL
+
COMP
Q1
ILIMIT
LOGIC
LEVEL SHIFTER
+
FET DRIVER
EN
LX
LX
500Khz
OSCILLATOR
AGND
February 2006
www.aosmd.com
PGND
Page 4 of 16
^lwNMNP
Typical Performance Characteristics
Circuit of figure 1. TA = 25°C, VIN = VEN = 12V, VOUT = 3.3V unless otherwise specified.
Full load (CCM) operation
Light load (DCM) operation
Vin
ripple
Vin
ripple
0.1V/div
50mV/div
Vo
ripple
Vo
ripple
50mV/div
50mV/div
Iin
2A/div
Iin
2A/div
VLX
10V/div
VLX
10V/div
1us/div
1us/div
Start up to full load
Full load to turn off
Vin
5V/div
Vin
5V/div
Vo
1V/div
Vo
1V/div
Iin
1A/div
Iin
1A/div
1ms/div
1ms/div
Load transient
Light load to turn off
Vo
Ripple
Vin
5V/div
0.1V/div
Vo
1V/div
Io
2A/div
100us/div
February 2006
Iin
1A/div
1s/div
www.aosmd.com
Page 5 of 16
^lwNMNP
Short circuit protection
Short circuit recovery
Vo
2V/div
Vo
2V/div
IL
2A/div
IL
2A/div
1ms/div
100us/div
Efficiency vs. load current
AOZ1013AI Efficiency
8.0V output
95%
5.0V output
Eff (%)
90%
8 V out
5 V out
3.3 V out
3.3V output
85%
80%
75%
0
0.5
1
1.5
2
2.5
3
Load current (A)
February 2006
www.aosmd.com
Page 6 of 16
^lwNMNP
Thermal de-rating curves for SO-8 package part under typical line and output voltage condition
Circuit of figure 1. 25ºC ambient temperature and natural convection (air speed<50LFM) unless otherwise
specified.
AOZ1013AI De-rating curves at 5 V input
De-rating Curve at 5V Input
3.5
3
5.0V output
2.5
Output Current (Io)
3.3V output
1.8V output
2
1.5
1
0.5
0
25
35
45
55
65
75
85
Ambient Temperature (Ta)
1.8V output
3.3V output
5V output
AOZ1013AI De-rating curves at 12V input
De-rating Curve at 12V Input
3.5
3
8.0V output
Output Current (Io)
2.5
5.0V output
3.3V output
2
1.8V output
1.5
1
0.5
0
25
35
45
55
65
75
85
Ambient Temperature (Ta)
1.8V output
February 2006
3.3V output
5.0V output
www.aosmd.com
8.0V output
Page 7 of 16
^lwNMNP
Detailed Description
The AOZ1013 is a current-mode step down regulator
with integrated high side PMOS switch and a low side
freewheeling Schottky diode. It operates from a 4.5V
to 16V input voltage range and supplies up to 3A of
load current. The duty cycle can be adjusted from 6%
to 100% allowing a wide range of output voltage.
Features include enable control, Power-On Reset,
input under voltage lockout, fixed internal soft-start
and thermal shut down.
The AOZ1013 is available in SO-8 package.
Enable and Soft Start
The AOZ1013 has internal soft start feature to limit inrush current and ensure the output voltage ramps up
smoothly to regulation voltage. A soft start process
begins when the input voltage rises to 4.0V and
voltage on EN pin is HIGH. In soft start process, the
output voltage is ramped to regulation voltage in
typically 4ms. The 4ms soft start time is set internally.
The EN pin of the AOZ1013 is active high. Connect
the EN pin to VIN if enable function is not used. Pull it
to ground will disable the AOZ1013. Do not leave it
open. The voltage on EN pin must be above 2.0 V to
enable the AOZ1013. When voltage on EN pin falls
below 0.6V, the AOZ1013 is disabled. If an application
circuit requires the AOZ1013 to be disabled, an open
drain or open collector circuit should be used to
interface to EN pin.
Steady-State Operation
Under steady-state conditions, the converter operates
in fixed frequency and Continuous-Conduction Mode
(CCM).
The AOZ1013 integrates an internal P-MOSFET as the
high-side switch. Inductor current is sensed by
amplifying the voltage drop across the drain to source
of the high side power MOSFET. Output voltage is
divided down by the external voltage divider at the FB
pin. The difference of the FB pin voltage and
reference
is
amplified
by
the
internal
transconductance error amplifier. The error voltage,
which shows on the COMP pin, is compared against
the current signal, which is sum of inductor current
signal and ramp compensation signal, at PWM
comparator input. If the current signal is less than the
error voltage, the internal high-side switch is on. The
inductor current flows from the input through the
inductor to the output. When the current signal
exceeds the error voltage, the high-side switch is off.
The AOZ1013 uses a P-Channel MOSFET as the high
side switch. It saves the bootstrap capacitor normally
seen in a circuit which is using an NMOS switch. It
allows 100% turn-on of the upper switch to achieve
linear regulation mode of operation. The minimum
voltage drop from VIN to VO is the load current times
DC resistance of MOSFET plus DC resistance of buck
inductor. It can be calculated by equation below:
VO _ MAX = VIN − I O × ( RDS ( ON ) + Rinductor )
Where VO_MAX is the maximum output voltage;
VIN is the input voltage from 4.5V to 16V;
IO is the output current from 0A to 3A;
RDS(ON) is the on resistance of internal
MOSFET, the value is between 40mΩ
and 70mΩ depending on input voltage and
junction temperature;
Rinductor is the inductor DC resistance;
Switching Frequency
The AOZ1013 switching frequency is fixed and set by
an internal oscillator. The practical switching
frequency could range from 350kHz to 600kHz due to
device variation.
Output Voltage Programming
Output voltage can be set by feeding back the output
to the FB pin with a resistor divider network. In the
application circuit shown in Figure 1. The resistor
divider network includes R1 and R2. Usually, a design
is started by picking a fixed R2 value and calculating
the required R1 with equation below.
VO = 0.8 × (1 +
R1
)
R2
Some standard value of R1, R2 for most commonly
used output voltage values are listed in Table 1.
Table 1.
Vo (V)
0.8
1.2
1.5
1.8
2.5
3.3
5.0
R1 (kΩ)
1.0
4.99
10
12.7
21.5
31.6
52.3
R2 (kΩ)
Open
10
11.5
10.2
10
10
10
Combination of R1 and R2 should be large enough to
avoid drawing excessive current from the output,
which will cause power loss.
The inductor current is freewheeling through the
external Schottky diode to output.
February 2006
www.aosmd.com
Page 8 of 16
^lwNMNP
Since the switch duty cycle can be as high as 100%,
the maximum output voltage can be set as high as
the input voltage minus the voltage drop on upper
PMOS and inductor.
Protection Features
The AOZ1013 has multiple protection features to
prevent system circuit damage under abnormal
conditions.
Over Current Protection (OCP)
The sensed inductor current signal is also used for
over current protection. Since AOZ1013 employs
peak current mode control, the COMP pin voltage is
proportional to the peak inductor current. The COMP
pin voltage is limited to be between 0.4V and 2.5V
internally. The peak inductor current is automatically
limited cycle by cycle.
The cycle by cycle current limit threshold is set
between 4A and 5A. When the load current reaches
the current limit threshold, the cycle by cycle current
limit circuit turns off the high side switch immediately
to terminate the current duty cycle. The inductor
current stop rising. The cycle by cycle current limit
protection directly limits inductor peak current. The
average inductor current is also limited due to the
limitation on peak inductor current. When cycle by
cycle current limit circuit is triggered, the output
voltage drops as the duty cycle decreasing.
When the junction temperature decreases to 100ºC.
Application Information
The basic AOZ1013 application circuit is shown in
Figure 1. Component selection is explained below.
Input capacitor
The input capacitor must be connected to the VIN pin
and PGND pin of the AOZ1013 to maintain steady
input voltage and filter out the pulsing input current.
The voltage rating of input capacitor must be greater
than maximum input voltage plus ripple voltage.
The input ripple voltage can be approximated by
equation below:
∆VIN =
IO
V
V
× (1 − O ) × O
f × C IN
VIN
VIN
Since the input current is discontinuous in a buck
converter, the current stress on the input capacitor is
another concern when selecting the capacitor. For a
buck circuit, the RMS value of input capacitor current
can be calculated by:
I CIN _ RMS = I O ×
VO
V
(1 − O )
VIN
VIN
if let m equal the conversion ratio:
The AOZ1013 has internal short circuit protection to
protect itself from catastrophic failure under output
short circuit conditions. The FB pin voltage is
proportional to the output voltage. Whenever FB pin
voltage is below 0.2V, the short circuit protection
circuit is triggered. As a result, the converter is shut
down and hiccups at a frequency equals to 1/8 of
normal switching frequency. The converter will start
up via a soft start once the short circuit condition
disappears. In short circuit protection mode, the
inductor average current is greatly reduced because
of the low hiccup frequency.
Power-On Reset (POR)
A power-on reset circuit monitors the input voltage.
When the input voltage exceeds 4V, the converter
starts operation. When input voltage falls below 3.7V,
the converter will be shut down.
VO
=m
VIN
The relation between the input capacitor RMS current
and voltage conversion ratio is calculated and shown
in Fig. 2 below. It can be seen that when VO is half of
VIN, CIN is under the worst current stress. The worst
current stress on CIN is 0.5·IO.
0.5
0.5
0.4
0.3
I CIN_RMS ( m)
IO
0.2
0.1
Thermal Protection
An internal temperature sensor monitors the junction
temperature. It shuts down the internal control circuit
and high side PMOS if the junction temperature
exceeds 145ºC. The regulator will restart
automatically under thecontrol of soft-start circuit
February 2006
www.aosmd.com
0
0
0
0
0.5
m
1
1
Figure 2. ICIN vs. voltage conversion ratio
Page 9 of 16
^lwNMNP
For reliable operation and best performance, the input
capacitors must have current rating higher than ICIN-RMS
at worst operating conditions. Ceramic capacitors are
preferred for input capacitors because of their low
ESR and high ripple current rating. Depending on the
application circuits, other low ESR tantalum capacitor
may also be used. When selecting ceramic
capacitors, X5R or X7R type dielectric ceramic
capacitors are preferred for their better temperature
and voltage characteristics. Note that the ripple
current rating from capacitor manufactures are based
on certain amount of life time. Further de-rating may
be necessary for practical design requirement.
Inductor
The inductor is used to supply constant current to
output when it is driven by a switching voltage. For
given input and output voltage, inductance and
switching frequency together decide the inductor
ripple current, which is,
∆I L =
VO
V
× (1 − O )
f ×L
VIN
Table 2.
Vout L1
5.0 V Shielded, 6.8uH
MSS1278-682MLD
Shielded, 6.8uH
MSS1260-682MLD
3.3 V Un-shielded, 4.7uH
DO3316P-472MLD
Shielded, 4.7uH
DO1260-472NXD
Shield, 3.3uH
ET553-3R3
1.8 V Shield, 2.2uH
ET553-2R2
Un-shielded, 3.3uH
DO3316P-222MLD
Shielded, 2.2uH
MSS1260-222NXD
Manufacture
Coilcraft
Coilcraft
Coilcraft
Coilcraft
ELYTONE
ELYTONE
Coilcraft
Coilcraft
Output Capacitor
The output capacitor is selected based on the DC
output voltage rating, output ripple voltage
specification and ripple current rating.
The peak inductor current is:
I Lpeak = I O +
Table below lists some inductors for typical output
voltage design.
∆I L
2
High inductance gives low inductor ripple current but
requires larger size inductor to avoid saturation. Low
ripple current reduces inductor core losses. It also
reduces RMS current through inductor and switches,
which results in less conduction loss. Usually, peak to
peak ripple current on inductor is designed to be 20%
to 30% of output current.
The selected output capacitor must have a higher
rated voltage specification than the maximum desired
output voltage including ripple. De-rating needs to be
considered for long term reliability.
Output ripple voltage specification is another
important factor for selecting the output capacitor. In
a buck converter circuit, output ripple voltage is
determined by inductor value, switching frequency,
output capacitor value and ESR. It can be calculated
by the equation below:
When selecting the inductor, make sure it is able to
handle the peak current without saturation even at the
highest operating temperature.
∆VO = ∆I L × ( ESRCO +
1
)
8 × f × CO
The inductor takes the highest current in a buck
circuit. The conduction loss on inductor needs to be
checked for thermal and efficiency requirements.
where CO is output capacitor value and ESRCO is the
Equivalent Series Resistor of output capacitor.
Surface mount inductors in different shape and styles
are available from Coilcraft, Elytone and Murata.
Shielded inductors are small and radiate less EMI
noise. But they cost more than unshielded inductors.
The choice depends on EMI requirement, price and
size.
When low ESR ceramic capacitor is used as output
capacitor, the impedance of the capacitor at the
switching frequency dominates. Output ripple is
mainly caused by capacitor value and inductor ripple
current. The output ripple voltage calculation can be
simplified to:
February 2006
www.aosmd.com
Page 10 of 16
^lwNMNP
If the impedance of ESR at switching frequency
dominates, the output ripple voltage is mainly
decided by capacitor ESR and inductor ripple current.
The output ripple voltage calculation can be further
simplified to:
∆VO = ∆I L × ESRCO
For lower output ripple voltage across the entire
operating temperature range, X5R or X7R dielectric
type of ceramic, or other low ESR tantalum are
recommended to be used as output capacitors.
In a buck converter, output capacitor current is
continuous. The RMS current of output capacitor is
decided by the peak to peak inductor ripple current. It
can be calculated by:
I CO _ RMS =
∆I L
12
Usually, the ripple current rating of the output
capacitor is a smaller issue because of the low
current stress. When the buck inductor is selected to
be very small and inductor ripple current is high,
output capacitor could be overstressed.
Loop Compensation
The AOZ1013 employs peak current mode control for
easy use and fast transient response. Peak current
mode control eliminates the double pole effect of the
output L&C filter. It greatly simplifies the
compensation loop design.
With peak current mode control, the buck power
stage can be simplified to be a one-pole and one-zero
system in frequency domain. The pole is dominant
pole and can be calculated by:
f p1 =
1
2π × CO × RL
The zero is a ESR zero due to output capacitor and its
ESR. It is can be calculated by:
f Z1 =
1
2π × CO × ESRCO
The compensation design is actually to shape the
converter close loop transfer function to get desired
gain and phase. Several different types of
compensation network can be used for the AOZ1013.
For most cases, a series capacitor and resistor
network connected to the COMP pin sets the polezero and is adequate for a stable high-bandwidth
control loop.
In the AOZ1013, FB pin and COMP pin are the
inverting input and the output of internal
transconductance error amplifier. A series R and C
compensation network connected to COMP provides
one pole and one zero. The pole is:
f p2 =
G EA
2π × CC × GVEA
Where GEA is the error amplifier transconductance,
which is 200•10-6 A/V;
GVEA is the error amplifier voltage gain,
which is 500 V/V;
CC is compensation capacitor;
The zero given by the external compensation network,
capacitor CC and resistor RC, is located at:
fZ2 =
1
2π × CC × RC
To design the compensation circuit, a target
crossover frequency fC for close loop must be
selected. The system crossover frequency is where
control loop has unity gain. The crossover frequency
is also called the converter bandwidth. Generally a
higher bandwidth means faster response to load
transient. However, the bandwidth should not be too
high because of system stability concern. When
designing the compensation loop, converter stability
under all line and load condition must be considered.
Usually, it is recommended to set the bandwidth to be
less than 1/10 of switching frequency. The AOZ1013
operates at a fixed switching frequency range from
350kHz to 600kHz. It is recommended to choose a
crossover frequency less than 30kHz.
f C = 30kHz
Where CO is the output filter capacitor;
RL is load resistor value;
ESRCO is the equivalent series resistance of
output capacitor;
February 2006
www.aosmd.com
Page 11 of 16
^lwNMNP
The strategy for choosing RC and CC is to set the
cross over frequency with RC and set the
compensator zero with CC. Using selected crossover
frequency, fC, to calculate RC:
RC = f C ×
2π × CO
VO
×
VFB GEA × GCS
The compensation capacitor CC and resistor RC
together make a zero. This zero is put somewhere
close to the dominate pole fp1 but lower than 1/5 of
selected crossover frequency. CC can is selected by:
Schottky
can
be
Pdiode _ loss = I O ⋅ (1 − D ) ⋅ VFW _ Schottky
Where VFW_Schottky is the Schottky diode forward
voltage drop.
The power dissipation of inductor can be
approximately calculated by output current and DCR
of inductor.
Pindcutor _ loss = I O ⋅ Rinductor ⋅ 1.1
2
T junction = ( Ptotal _ loss − Pdiode _ loss − Pinductor _ loss ) ⋅ Θ JA
Equation above can also be simplified to:
CO × R L
RC
An easy-to-use application software which helps to
design and simulate the compensation loop can be
found at www.aosmd.com.
Thermal management and layout consideration
In the AOZ1013 buck regulator circuit, high pulsing
current flows through two circuit loops. The first loop
starts from the input capacitors, to the VIN pin, to the
LX pins, to the filter inductor, to the output capacitor
and load, and then return to the input capacitor
through ground. Current flows in the first loop when
the high side switch is on. The second loop starts
from inductor, to the output capacitors and load, to
the anode of Schottky diode, to the cathode of
Schottky diode. Current flows in the second loop
when the low side diode is on.
In PCB layout, minimizing the two loops area reduces
the noise of this circuit and improves efficiency. A
ground plane is strongly recommended to connect
input capacitor, output capacitor, and PGND pin of
the AOZ1013.
In the AOZ1013 buck regulator circuit, the major
power dissipating components are the AOZ1013, the
Schottky diode and output inductor. The total power
February 2006
in
The actual junction temperature can be calculated with
power dissipation in the AOZ1013 and thermal
impedance from junction to ambient.
1 .5
2π × RC × f p1
CC =
Ptotal _ loss = VIN ⋅ I IN − VO ⋅ I O
The power dissipation
approximated as:
where fC is desired crossover frequency;
VFB is 0.8V;
GEA is the error amplifier transconductance,
which is 200•10-6 A/V;
GCS is the current sense circuit
transconductance, which is 6.68 A/V;
CC =
dissipation of converter circuit can be measured by
input power minus output power.
The maximum junction temperature of AOZ1013 is
150ºC, which limits the maximum load current
capability. Please see the thermal de-rating curves for
maximum load current of the AOZ1013 under different
ambient temperature.
The thermal performance of the AOZ1013 is strongly
affected by the PCB layout. Extra care should be
taken by users during design process to ensure that
the IC will operate under the recommended
environmental conditions.
Several layout tips are listed below for the best electric
and thermal performance. Figure 3 below illustrate a
PCB layout example as reference.
1. Do not use thermal relief connection to the
VIN and the PGND pin. Pour a maximized
copper area to the PGND pin and the VIN pin
to help thermal dissipation.
2. Input capacitor should be connected to the
VIN pin and the PGND pin as close as
possible.
3. A ground plane is preferred. If a ground plane
is not used, separate PGND from AGND and
connect them only at one point to avoid the
PGND pin noise coupling to the AGND pin.
4. Make the current trace from LX pins to L to Co
to the PGND as short as possible.
www.aosmd.com
Page 12 of 16
^lwNMNP
5. Pour copper plane on all unused board area
and connect it to stable DC nodes, like VIN,
GND or VOUT.
6. The two LX pins are connected to internal
PFET drain. They are low resistance thermal
conduction path and most noisy switching
node. Connected a copper plane to LX pin to
help thermal dissipation. This copper plane
should not be too larger otherwise switching
noise may be coupled to other part of circuit.
7. Keep sensitive signal trace far away form the
LX pins.
Vin
Vo
L
Cin
Vin
LX
PG
LX
Cout
AG
EN
FB
CP
GND
Via to ground plane
Figure 3. AOZ1013 PCB layout
February 2006
www.aosmd.com
Page 13 of 16
^lwNMNP
SO-8 Package Marking Description
Z1013AI
FAYWLT
Note:
Logo
Z1013AI
F&A
Y
W
L&T
February 2006
AOS logo
Part number code
Fab & Assembly location
Year code
Week code
Assembly lot code
www.aosmd.com
Page 14 of 16
^lwNMNP
February 2006
www.aosmd.com
Page 15 of 16
^lwNMNP
February 2006
www.aosmd.com
Page 16 of 16