ARTESYN EXB100

EXB100 Series
Single output
DC/DC CONVERTERS
•
•
•
•
•
•
•
54-100W DC/DC Isolated Converters
1
NEW Product
Ultra wide trim range, 60% to 110% (1.08V to 5.5V)
High efficiency, 91.5% @ 5V, 90.5% @ 3.3V, 87.5% @ 1.8V
Basic insulation (input to output)
Industry standard half-brick pin-out
No minimum load
Over-voltage and over-temperature protection
Remote ON/OFF
The EXB100 series of 100W single output isolated DC/DC converters are specially
designed to meet the power needs of low voltage silicon. Housed in an open-frame
package with standard footprint, these latest generation converters offer efficiencies as
high as 91.5% (typical on 5V at 20A). The series comprises three 48V input models with
5V, 3.3V and 1.8V outputs. All models feature a wide input range, trimmable output
voltage and 30A output (5V is limited to 20A). Remote sense and remote ON/OFF
facilities are included as standard, and the converters are comprehensively protected
against over-current, over-voltage and over-temperature conditions.
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
60% to 110%
Output setpoint accuracy
1.5%
Line regulation
Low line to high line
±0.2% max.
Load regulation
Full load to min. load
±0.4% max.
Total error band
Overshoot
None
None
GENERAL SPECIFICATIONS
0%
At turn-on and turn-off
Undershoot
Ripple and noise
5Hz to 20MHz
(See Note 1)
Transient response
(See Note 2)
Deviation
100mV pk-pk
50mV rms
150mV
300µs recovery to
within total error band
EN61000-4-2 8kV, 15kV
EN61000-4-2 6kV, 8kV
EN61000-4-3 10V/m
EN61000-4-6 10V
EN61000-4-6 10V
ETS 300 132-2, ETR 283
Efficiency
Input voltage range
36 to 75VDC
No load
Remote OFF
150mA
20mA
Basic insulation
Input/output
Switching frequency
(Fixed)
5V
3.3V, 1.8V
Input current (max.)
(See Note 3)
3.15A max. @ Io max.
and Vin = 36 to 75V
Input reflected ripple
(See Note 4)
60mA (pk-pk)
Remote ON/OFF
Logic compatibility
ON
OFF
(See Note 5)
Open collector ref to -input
>2VDC
<1.2VDC
Under-voltage lockout
Power up
Power down
Start-up time
(See Note 6)
Power up
Remote ON/OFF
36V
30V
(See Note 5)
1500VDC
300kHz typ.
220kHz typ.
TÜV Product Service
UL/cUL60950
Material flammability
UL94V-0
Weight
MTBF
Representative model:
Level A
Level B
Level A
See table
Approvals and
standards (See Note 8)
INPUT SPECIFICATIONS
Input current
Radiated emissions
EN55022 (See Note 7)
EN55022 (See Note 7)
EN55022
(See Long Form Data Sheet)
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
3.0%
Minimum load
Conducted emissions
45g (1.59oz)
MIL-HDBK-217F
115,000 hours
1V8 @ 48Vin, 40ºC
100% load, ground benign
BELLCORE 332
591,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Altitude derating
(above sea level)
Operating ambient.
temperature
Non-operating
3,000m
10,000m
-40°C to +90°C
-40°C to +125°C
20%
50%
40ms
35ms
File Name: EXB100S.PDF Rev: 29 March 2002
EXB100 Series
Single output
DC/DC CONVERTERS
54-100W DC/DC Isolated Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
100W
36-75VDC
6.0VDC
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
LINE
LOAD
MODEL
NUMBER (9)
5.0V
0A
20A
91.5%
±0.2%
±0.4%
EXB100-48S05
3
4
5
6
7
8
9
REGULATION
100W
36-75VDC
3.9VDC
3.3V
0A
30A
90.5%
±0.2%
±0.4%
EXB100-48S3V3
54W
36-75VDC
2.2VDC
1.8V
0A
30A
87.5%
±0.2%
±0.4%
EXB100-48S1V8
Notes
1
2
NEW Product
PROTECTION
Measured as per recommended set-up. See Application Note 129 for details.
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to 0.75
lo max. and 0.75 lo max. to 0.5 lo max.
Recommended input fusing is a 5A HRC 200V rated fuse.
Measured with external filter. See Application Note 129 for details.
Signal line assumed <3m in length.
Start-up into resistive load.
The EXB100 meets levels A and B conducted emissions with external
components. See Application Note 129 for details.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example EXB100-48S3V3-R.
Short circuit protection
Continuous
Overvoltage protection
Non-latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2 input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PIN CONNECTIONS
+Vin
5
+Vout
6
+Sense
7
Trim
8
-Sense
9
-Vout
Vin-
VoSenseTrim
Sense+
Remote
ON/OFF
0.400
(10.16)
0.700
0.500
(17.78)
(12.70)
1.000
(25.40)
1.400
(35.56)
4
Ø0.040 ±0.002
(Ø1.02 ±0.05)
6 Places
Ø0.080 ±0.002
(Ø2.03 ±0.05)
Minimum clearance from
2 Places
seating plane to
underside components
All dimensions in inches (mm)
General tolerance ±0.01in (±0.25mm)
except where specified otherwise
2.280±0.02
(57.91±0.5)
0.161
(4.09)
Remote ON/OFF
0.138
(3.50)
3
seating plane
1.000
(25.40)
No Pin
0.012
(0.3)
Min
2
0.500
(12.70)
-Vin
1.400
(35.56)
1
Max open-frame
converter height
0.394
(10.00)
Max
FUNCTION
2.400±0.02
(60.96±0.5)
PIN NUMBER
Vo+
Vin+
International Safety Standard Approvals
1.900
(48.26)
Bottom View
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV
TÜV Product Service. Certificate No. B 02 02 38572 031
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note ✔ Longform Data Sheet
www.artesyn.com
File Name: EXB100S.PDF Rev: 29 March 2002