ARTESYN SXA15

SXE15 Series
Single output
DC/DC CONVERTERS
10.8-15W High Efficiency DC/DC Converters
1
• High efficiency topology, 87% typical at 5V
• Wide operating temperature, up to and exceeding 70˚C
(natural convection)
• 90% to 110% output trim
• No minimum load
• Overvoltage protection
• Remote on/off control
The SXE15 is a new high efficiency open frame isolated 15 Watt converter series in
an industry standard footprint. All models in the series feature an input voltage range
of 33 to 75VDC and are available in output voltages of 12V, 5V, 3.3V, 2.5V and 1.8V.
The output voltage on each model is adjustable from 90% to 110% of the nominal
value. Typical efficiencies for the models are 87% for the 5V, 86% for the 3.3V, 85%
for the 2.5V and 12V and 83% for the 1.8V version. The SXE15 series also has a
remote on/off capability with active high or active low logic. Overcurrent and
overvoltage protection features are included as standard. With full international
safety approval including EN60950 and cUL1950, the SXE15 reduces compliance
costs and time to market.
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
90% to 110%
Total error band
(See Note 14)
±4% max.
Line regulation
Low line to high line
1V8 and 2V5 models
3V3 and S05 models
0.5% max.
0.1% max.
Load regulation
Full load to min. load
1V8 model
2V5 model
3V3 and S05 models
2.0% max.
1.5% max
0.5% max.
Minimum load
(See Note 13)
Overshoot
At turn-on and turn-off
1V8 and 2V5 models
3V3 and S05 models
0%
Undershoot
Ripple and noise
(See Note 1)
5Hz to 20MHz
Transient response
(See Note 2)
Typical deviation
4% max.
None
None
1V8 and 2V5 models
3V3 and S05 models
40mV pk-pk
14mV rms
70mV pk-p
20mV rms
1V8 and 2V5 models
3V3 and S05 models
150mV
100mV
400µs recovery to
within total error band
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
EN55022 (See Longform data sheet) Level B
EN61000-4-2 8kV, 15kV
EN61000-4-2 6kV, 8kV
EN61000-4-3 10V/m
EN61000-4-6 10V
EN61000-4-6 10V
ETS 300 132-2, ETR 283
Input voltage range
48Vin nominal
Input current
No load
Remote OFF
35mA max.
25mA max.
Input current (max.)
(See Note 4)
0.55A max. @ Io max.
and Vin = 33 to 75V
(See Note 6)
Active high remote ON/OFF
Logic compatibility
ON
OFF
33 to 75VDC
5mA (pk-pk) typ.
(See Note 8)
Open collector ref to -input
Open circuit or >2VDC
<1.2VDC
Undervoltage lockout
Power up
Power down
Start-up time
(See Note 7)
Power up
Remote ON/OFF
33V (typ.)
30V (typ.)
1.5ms (typ.)
2.5ms (typ.)
(See Note 12)
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation
Input/output
Switching frequency
Fixed
1500VDC
265kHz typ.
Approvals and
standards
(See Notes 5 and 11)
UL/cUL1950, EN60950
TÜV Rheinland
Material flammability
UL94V-0
Weight
INPUT SPECIFICATIONS
Input reflected ripple
Conducted emissions
MTBF
Representative model:
12g (0.42oz)
MIL-HDBK-217F
>600,000 hours
48S05 @ 48Vin, 40°C,
100% load ground benign
BELLCORE 332
>1,500,000
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Note 9)
Operating ambient
temp. (5V and 3.3V)
Operating ambient
temp. (1.8V, 2.5V
and 12V)
Non-operating
(All models)
-40°C to +65°C
-40°C to +70°C
-40°C to +120°C
File Name: SXE15S.PDF Rev: 17 Oct 2002
SXE15 Series
Single output
DC/DC CONVERTERS
10.8-15W High Efficiency DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
LINE
LOAD
MODEL
NUMBER (8)
10.8W
33-75VDC
2.3VDC
1.8V
0A
6A
83%
0.3%
2.0%
SXE15-48S1V8
15W
33-75VDC
3.2VDC
2.5V
0A
6A
85%
0.3%
1.5%
SXE15-48S2V5
15W
33-75VDC
4VDC
3.3V
0A
4.5A
86%
0.1%
0.5%
SXE15-48S3V3
15W
33-75VDC
15W
33-75VDC
6VDC
15VDC
(10)
5.0V
0A
3A
87%
0.1%
0.5%
SXE15-48S05
12.0V
0A
1.25A
85%
0.1%
0.5%
SXE15-48S12
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
REGULATION
PROTECTION
Measured as per recommended set-up. See Application Note 116 for details.
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to 0.75
lo max. and 0.75 lo max. to 0.5 lo max.
The SXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
Recommended input fusing is a 2A HRC 200V rated fuse.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured with external Pi filter. See Application Note 116 for further details.
Start-up into resistive load.
Active low remote on/off is available. Standard product is active high.
Designate with the Suffix ‘-R’ e.g. SXE15-48S05-R.
Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
SXE15-48S12 below 0.2A loading. OVP is TVS and 17V typical.
Approvals pending for the SXE12-48S12.
Signal line assumed < 3m in length.
A 5% minimum load is required to maintain the output voltage regulation
over all operating conditions for the SXE15-48S12.
This parameter is calculated at worst case line, load,
temperature and initial settings.
PIN CONNECTIONS
Short circuit protection
Continuous
Overvoltage protection
Latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TÜV
TÜV Rheinland. Certificate No. R2074133
1.905 (48.39)
overall length
1.150 (29.21)
1.390 (35.31)
TOP VIEW
PIN NUMBER
FEATURE
1
Vout +
2
Vout -
1.885 (47.88)
3
N/C
4
Trim
5
N/C
leadframe length
0.070 (1.78) MAX
0.335 (8.51) MAX
SIDE VIEW
0.010 (0.25) MIN
1.812 (46.03)
Tolerence: ±.015 (±.38)
Recommended Land & Hole Pattern
1.575 (40.01)
0.197 (5.00)
6
N/C
0.394 (10.01)
1.812 (46.02)
7
N/C
BOTTOM VIEW
0.063 (1.60)
ø0.063 (ø1.60)
0.047 (1.18)
1.200 (30.48)
1.812 (46.02)
0.477 (12.11)
8
On/Off
9
N/C
10
N/C
0.069 (1.74)
11
Vin -
0.394 (10.01)
12
Vin +
ø.050 (ø1.27)
Non-Skid Retaining Pins,
2 Places
0.502 (12.75)
0.125 (3.18)
0.161 (4.09)
1
0.130 (3.30)
0.053 (1.36)
1.181 (30.00)
0.197 (5.00)
0.100 (2.54)
12 places
1.378 (35.00)
All Dimensions in Inches [mm]
1.181 (30.00)
1.378 (35.00)
1.575 (40.01)
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note ✔ Longform Data Sheet
www.artesyn.com
File Name: SXE15S.PDF Rev: 17 Oct 2002