ASTEC DTX42K48-S

Embedded Power for
Business-Critical Continuity
Rev. 09.29.05
DTX Series
1 of 2
DTX42K48
42 Amps
Total Power:
50 Watts
Input Voltage: 48V
# of Outputs: Single
Electrical Specifications
Input
Special Features
• Fully Digital-mode DC-DC converter
• Extensive PMBusTM command
set implementation for
maximum control opportunity
• Efficiency optimizer
(Pat. Pending)
• Self Diagnostics (Pat. Pending)
• User accessible data storage
• Low profile SMT termination
for tight-fit applications
(portable equipment, etc)
• User accessible operating code
for optimum flexibility
• Basic Insulation
Input range
36 to 75VDC
Input surge
Under voltage lock-out
100V / 100ms
Programmable
34V - 36V (default turn-on)
30V - 33V (default turn-off)
Output
Line regulation
Load regulation
Output voltage setpoint
Noise/ripple2
Remote sense
Transient response2
±0.18%Vo
±0.1%Vo
±0.5%
25mV Typ
Differential mode - up to 10%Vo
Programmable Loop compensation
Default: 5% Vo deviation
50% to 75% load change
Programmable range and mode
Overvoltage protection
Default - 115% lo
Programmable range and mode
Over current protection
Default - 115% lo
Over temperature protection Programmable range and mode
Default - 110°C (at ref sense point)
Programmable - 380 KHz default
Switching frequency
1500 Vdc
Isolation Voltage
Control
Voltage Adjust
Enable
Programmable range: 0.96V to 1.44V
Programmable Logic (posititve and negative)
Environmental Specifications
Safety
UL, cUL 60950 (Pending)
TUV
EN60950 (Pending)
Ambient air operating temperature range -40°C to +85°C
Storage temperature
-40°C to +125°C
MTBF
>1 million hours
Embedded Power for
Business-Critical Continuity
Astec Power
Ordering Information
Input Voltage Output Voltage Output Current Efficiency
36V to 75V
1.2V
42A
86% (Typ)
Model Number
DTX42K48-S
Pin Assignments
Power Train
PMBusTM
Pin No
Pin No
Symbol
ADC Input
Symbol
1
+Vin
12
PMBus SDA
2
Enable
13
3
-Vin
15
4
+Sense
Pin No
14
Symbol
ADC Ext
Programming3
Pin No
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Technical Support: +1 888 41 ASTEC
or +1 407 241 2752
Symbol
16
C2Bus Gnd
PMBus SCL
17
C2CK
PMBus Gnd
18
C2D
19
-Vin
5, 7, 9 +Vout
20
C2CK300
6, 8, 10 -Vout
21
C2D 300
11
22
C2_Prog Bias
-Sense
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
3. Programming pins for advance feature sets / customer specific features not required
for normal operation.
Units 2111-2116, Level 21
Tower 1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: +852 2437 9662
Facsimile: +852 2402 4426
4. Technical reference Notes should be consulted for detailed information when
available.
For global contact, visit:
Notes:
1. All specifications are typical at nominal line, full load and TA = 25 °C unless otherwise
noted.
2. Measurements taken with output capacitive termination: 10mF tantalum in parallel
with 0.1mF ceramic capacitor.
5. All specifications subject to change without notice.
Mechanical Outline
Rev. 09.29.05
DTXSeries
2 of 2
www.astecpower.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Astec
Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Printed in US A
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2005 Emerson Electric Co.