1 5 0 W 2 ” x 4 ” O p en Frame Switching Power Supplies ASL150 series Single Outputs with 12V Auxillary Universal 90 to 264VAC Input 5VDC to 48VDC Outputs 3,000VAC Input to Output Isolation Short Circuit Protection Full Safety Approvals Model Number V1 I1 Air Flow Convection / 200LFM I2 (12V aux.) Convection / 200LFM ASL150-5 ASL150-12 ASL150-24 ASL150-48 5VDC 12VDC 24VDC 48VDC 16 / 20A 8.3 / 13.3A 4.16 / 6.66A 2.08 / 3.33A 0.5 / 0.5A 0.5 / 0.5A 0.5 / 0.5A 0.5 / 0.5A Note: All Products are 0-100% Load Operation (Pending) WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 ASL150 1 5 0 W 2 ” x 4 ” O p en Frame Switching Power Supplies GENERAL SPECIFICATIONS INPUT SPECIFICATIONS Input Voltage Range (AC / DC) Input Current Inrush Current Input Frequency Power Factor (90VAC) Harmonic Input Current Input Fuse Under Voltage Lockout Leakage Current (120V I/P) series 90-264 / 170-370 <2.5A @ 100VAC No Damage @ 230VAC Cold Start 47-63Hz 0.98% Meets EN61000-3-2 3A Internal Line & Neutral 80VAC Auto Recover <275uA OUTPUT SPECIFICATIONS Setpoint Accuracy +/-1% Main Output V1 Overshoot during Power-on Out of regulation 50mS, max. Voltage Adjust 5% Main Output V1 Load Regulation +/-1% V1; +/-20% V2 Line Regulation +/-0.1% 90-264VAC Cross Regulation +/-1% V1; +/-15% V2 Transient Response (50% Load Change) 10% Recover within 1mS Start Up (HL; FL) 500mS Rise / Hold Up Time 20mS / 16mS Temperature Coefficient +/-0.25mV/°C Ripple/Noise: 20Mhz BW, resistive load, with 22uF (tantalum) and 0.47uF (ceramic) parallel capacitors at POL 1% of Output (42% 12V aux.) Over-voltage Protection 130% max. Over Current Protection 130% max. Auto Recover* Short Circuit and Over Temp Protection Auto Recovery * * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted WWW.ASTRODYNE.COM I/P-O/P Isolation I/P-Ground Isolation O/P-O/P Isolation O/P-Ground Isolation 3000VAC for 1 Minute 1500VAC for 1 Minute 100VDC for 1 Minute 500VAC for 1 Minute ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Cooling Relative Humidity Storage Temperature Operating Altitude MTBF EMC / CE Mark Requirements Voltage Fluctuation ESD Radiated Field EFT Surge Conducted RF Voltage Variations Safety Standards (PENDING) -20 to +50°C FL Derate Linearly to 50% Load at 70°C * 200LFM >100W O/P Power 8-90% Non Cond (95% Non-Oper.) -40 to +80°C * 5000 ft Above Sea Level Derate to 40°C ambient @ 10,000 ft Convection Cooled: 150,000Hrs Air Flow (200 CFM): 300,000 Hrs EN55024 EN61000-3-3 15KV Air, 8KV Contact 3V/m, 80-1000MHz 80% Modulation at distance of 3M ±2kV on AC power port for1 minute; ±1kV on signal/ctrl lines ±1kV line to line/±2kV line to earth on AC power port; ±0.5kV for outdoor cables 3V; 0.15-80MHz 80% Modulation >95% dip, 0.5 period; 30% dip, 25 periods; >95% reduction, 250 periods EN60950, IEC60950, UL/cUL 60950 Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 1 5 0 W 2 ” x 4 ” O p en Frame Switching Power Supplies ASL150 series MECHANICAL DIMENSIONS WEIGHT: 5.7 OZ WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 1 5 0 W 2 ” x 4 ” O p en Frame Switching Power Supplies ASL150 series Derate curve WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060