S324 Semiconductor Low Power Quad OP AMP Description The S324 consists of four independent high gain Internally frequency compensated operational amplifiers designed to operate from a single power supply over a wide range of voltage. Features • • • • • • Input common mode voltage range includes ground Internally frequency compensated for unity gain Large DC voltage gain : 100dB Wide bandwidth for unity gain : 1 MHz Very low power consumption Wide supply voltage range : Single : 3V ~ 36V, Dual : ±1.5 ~ ±18V Applications • Transducer amplifier • DC gain blocks • Conventional operational amplifiers Ordering Information Type NO. S324 Marking Package Code S324 SOP-14 Outline Dimensions unit : mm Block Diagram KSI-K001-001 1 S324 Absolute maximum ratings Characteristic Symbol Ratings Unit Supply voltage VCC 36 or ±18 V Differential input voltage VIND 36 V Input voltage VIN -0.3 ~ +36 V Power Dissipation PD 300 mW Operating temperature Topr -40 ~ +85 °C Storage temperature Tstg -55 ~ 150 °C Electrical Characteristics (Unless otherwise specified. VCC = 5V, VEE = GND and –40 °C ≤ Ta ≤ +85 °C) Characteristic Symbol Input offset voltage VIOS Input offset current IIOS Input bias current IIB Test Condition VCC = 5~30V Rg = 0Ω Min. Typ. Max. Unit - 2 7 mV - - 5 30 nA - - 45 150 nA Input common mode voltage range VICR VCC = 30V 0 - VCC –1.5 V Supply current ICC RL = ∞, All Channel - 0.7 1.2 mA Large signal voltage gain GV VCC = 15V RL ≥ 2 KΩ 86 100 - dB RL=2 KΩ 26 - - RL=10 KΩ 27 28 - - 5 20 mV Output voltage swing VOH VOL VCC = 30V VCC =5V, RL ≤10 KΩ V Common mode rejection ratio CMRR (Ta=25 °C) 65 85 - dB Power supply rejection ratio PSRR (Ta=25 °C) 65 100 - dB VCC = 15V VIN+ = 1V, VIN- = 0V 20 40 - mA VCC = 15V VIN+ = 0V, VIN- = 1V 10 20 - mA VOUT = 200mV, VIN+= 0V, VIN-= 1V, VCC= 15V 12 45 - µA Output source current Output sink current IO+ IO- KSI-K001-001 2 S324 Electrical Characteristic Curves Fig. 1 ICC-VCC Fig. 2 IIB-VCC Fig. 3 VIOS-Ta Fig. 4 IO-Ta Fig. 5 CMRR-f Fig. 6 VOR-f KSI-K001-001 3 S324 These AUK products are intended for usage in general electronic equipments(Office and communication equipment, measuring equipment, domestic electrification, etc.). Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.). AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK. KSI-K001-001 4